Validation Results for CIBMTRReporting

Generated Thu Jun 25 19:34:02 CDT 2026, FHIR version 4.0.1 for nmdp.fhir.cibmtr-reporting#0.1.11 (canonical = http://fhir.nmdp.org/ig/cibmtr-reporting (history)). See Full QA Report & IP

Quality Checks
Publisher Version:IG Publisher Version: v2.0.29, which is out of date. The current version is v2.2.10 Download Latest
Publication Code:n/a . PackageId = nmdp.fhir.cibmtr-reporting, Canonical = http://fhir.nmdp.org/ig/cibmtr-reporting
Realm Check for n/a:
  • n/a
Language Info:This IG has no language information
Publication Request:
package-idnmdp.fhir.cibmtr-reporting
version0.1.11
pathhttp://fhir.nmdp.org/ig/cibmtr-reporting/0.1.11
Pub-Modemilestone
statusrelease
Release-LabelTrial Use 1
Sequence (Group)Release
descGuidance and Profile pages restructured and consolidated; Patient, Medication, Laboratory Observation, and Vital Signs guidance updated
categoryResearch
titleCIBMTR Reporting Implementation Guide
introductionThe [Center for International Blood & Marrow Transplant Research® (CIBMTR®)] CIBMTR is a collaborative resource of data and experts supporting research in cellular therapies to improve patient outcomes. The CIBMTR facilitates critical observational and interventional research through scientific and statistical expertise, a large network of transplant centers, and a unique and extensive clinical outcomes database. This IG describes how to report these data to CIBMTR.
ci-buildhttp://nmdp-ig.github.io/cibmtr-reporting-ig
RelatedIgs(None Found)
  • Error fetching package-list from http://fhir.nmdp.org/ig/cibmtr-reporting: Service Unavailable
  • This appears to be the first publication, so first must be true
  • This IG is not yet published at all, so there must be "first" : true in the publication request
Supressed Messages:No Suppressed Issues
Dependency Checks:
PackageVersionFHIRCanonicalWeb BaseComment
.. nmdp.fhir.cibmtr-reporting0.1.11R4http://fhir.nmdp.org/ig/cibmtr-reporting
... hl7.terminology.r47.2.0 MR4http://terminology.hl7.orghttp://terminology.hl7.org/7.2.0
.... hl7.fhir.uv.extensions.r45.3.0 MR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.3.0
..... hl7.terminology.r47.1.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/7.1.0Latest Release is 7.2.0
...... hl7.fhir.uv.extensions.r45.2.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0Latest Release is 5.3.0
... hl7.fhir.uv.extensions.r45.3.0 MR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.3.0 (as above)
... hl7.fhir.us.core8.0.0 OR4http://hl7.org/fhir/us/corehttp://hl7.org/fhir/us/core/STU8Latest Release is 9.0.0
.... hl7.terminology.r46.4.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/6.4.0Latest Release is 7.2.0
..... hl7.fhir.uv.extensions.r45.2.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0 (as above). Latest Release is 5.3.0
.... hl7.fhir.uv.smart-app-launch2.2.0 MR4http://hl7.org/fhir/smart-app-launchhttp://hl7.org/fhir/smart-app-launch/STU2.2
..... hl7.fhir.uv.extensions5.1.0-snapshot1 OR5http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.1.0-snapshot1FHIR Version Mismatch. Latest Release is 5.3.0
...... hl7.terminology.r55.3.0 OR5http://terminology.hl7.orghttp://terminology.hl7.org/5.3.0FHIR Version Mismatch. Latest Release is 7.2.0
..... hl7.terminology5.5.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/5.5.0Latest Release is 7.2.0
...... hl7.fhir.uv.extensions.r41.0.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/1.0.0Latest Release is 5.3.0
.... us.nlm.vsac0.23.0 OR4http://fhir.org/packages/us.nlm.vsachttp://fhir.org/packages/us.nlm.vsacLatest Release is 0.24.0
.... hl7.fhir.uv.sdc3.0.0 OR4http://hl7.org/fhir/uv/sdchttp://hl7.org/fhir/uv/sdc/STU3Latest Release is 4.0.0
..... hl7.fhir.r4.examples4.0.1 OR4http://hl7.org/fhirhttp://hl7.org/fhir/R4Latest Release is 5.0.0
.... us.cdc.phinvads0.12.0 MR4http://fhir.org/packages/us.cdc.phinvadshttp://fhir.org/packages/us.cdc.phinvads
.... hl7.fhir.uv.extensions.r45.2.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0 (as above). Latest Release is 5.3.0
.... hl7.terminology.r46.2.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/6.2.0Latest Release is 7.2.0
.... hl7.fhir.uv.extensions.r45.2.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0 (as above). Latest Release is 5.3.0
.... hl7.fhir.uv.genomics-reporting2.0.0 OR4http://hl7.org/fhir/uv/genomics-reportinghttp://hl7.org/fhir/uv/genomics-reporting/STU2Latest Release is 3.0.0
.... hl7.fhir.us.core6.1.0 OR4http://hl7.org/fhir/us/corehttp://hl7.org/fhir/us/core/STU6.1Latest Release is 9.0.0
..... hl7.terminology.r45.0.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/5.0.0Latest Release is 7.2.0
..... hl7.fhir.uv.extensions.r41.0.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/1.0.0 (as above). Latest Release is 5.3.0
..... hl7.fhir.uv.bulkdata2.0.0 OR4http://hl7.org/fhir/uv/bulkdatahttp://hl7.org/fhir/uv/bulkdata/STU2Latest Release is 3.0.0
..... hl7.fhir.uv.smart-app-launch2.1.0 OR4http://hl7.org/fhir/smart-app-launchhttp://hl7.org/fhir/smart-app-launch/STU2.1Latest Release is 2.2.0
...... hl7.terminology.r45.0.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/5.0.0 (as above). Latest Release is 7.2.0
..... us.nlm.vsac0.11.0 OR4http://fhir.org/packages/us.nlm.vsachttp://fhir.org/packages/us.nlm.vsacLatest Release is 0.24.0
..... hl7.fhir.uv.sdc3.0.0 OR4http://hl7.org/fhir/uv/sdchttp://hl7.org/fhir/uv/sdc/STU3 (as above). Latest Release is 4.0.0
..... us.cdc.phinvads0.12.0 MR4http://fhir.org/packages/us.cdc.phinvadshttp://fhir.org/packages/us.cdc.phinvads (as above)
..... ihe.formatcode.fhir1.1.0 OR4https://profiles.ihe.net/fhir/ihe.formatcode.fhirhttps://profiles.ihe.net/fhir/ihe.formatcode.fhir/1.1.0Latest Release is 1.5.0
... hl7.fhir.uv.genomics-reporting2.0.0 OR4http://hl7.org/fhir/uv/genomics-reportinghttp://hl7.org/fhir/uv/genomics-reporting/STU2 (as above). Latest Release is 3.0.0
... hl7.fhir.uv.tools.r40.9.0 OR4http://hl7.org/fhir/toolshttp://hl7.org/fhir/tools/0.9.0Internal Dependency. Latest Release is 1.1.2
Templates: cibmtr-template#0.1.0 -> fhir.base.template#current
Related IGs:n/a
Dependent IGs:no references
Global Profiles:(none declared)
Terminology Server(s):https://tx.fhir.org/r4 (details)
HTA Analysis:Non-HL7 Igs are exempt from terminology dependency analysis
R5 Dependencies:(none)
Draft Dependencies:
Modifier Extensions:(none)
Previous Version Comparison: Unable to compare with previous version: Unable to find version history at http://fhir.nmdp.org/ig/cibmtr-reporting (Problem #1 with package-list.json at http://fhir.nmdp.org/ig/cibmtr-reporting: Read timed out)
IPA Comparison: n/a
IPS Comparison: n/a
Validation Flags: On: autoLoad; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent, displayWarnings
Summary: errors = 7, warn = 237, info = 348, broken links = 1, pinned = n/a.
FilenameErrorsWarningsHints
Build Errors170
D:\IG\0515_Final\build\fsh-generated\resources\CodeSystem-cibmtr-ancestry-cs221
D:\IG\0515_Final\build\fsh-generated\resources\ImplementationGuide-nmdp.fhir.cibmtr-reporting020
D:\IG\0515_Final\build\fsh-generated\resources\Medication-Medication-Cyclophosphamide-Example021
D:\IG\0515_Final\build\fsh-generated\resources\Medication-Medication-Etoposide-Example021
D:\IG\0515_Final\build\fsh-generated\resources\Medication-Medication-GVHD-Prophylaxis-Example021
D:\IG\0515_Final\build\fsh-generated\resources\Medication-Medication-Mobilizing-Agent-Example021
D:\IG\0515_Final\build\fsh-generated\resources\Medication-Medication-Peri-Transplant-Example021
D:\IG\0515_Final\build\fsh-generated\resources\Medication-Medication-Post-HCT-Disease-Therapy-Example021
D:\IG\0515_Final\build\fsh-generated\resources\Medication-Medication-Prep-Regimen-Example021
D:\IG\0515_Final\build\fsh-generated\resources\Medication-Medication-PriorExposure-Example021
D:\IG\0515_Final\build\fsh-generated\resources\MedicationAdministration-MedicationAdministration-Example1011
D:\IG\0515_Final\build\fsh-generated\resources\MedicationAdministration-MedicationAdministration-Example2021
D:\IG\0515_Final\build\fsh-generated\resources\MedicationRequest-MedicationRequest-Etoposide-Example011
D:\IG\0515_Final\build\fsh-generated\resources\Observation-ABOBloodGroupObservationLOINC031
D:\IG\0515_Final\build\fsh-generated\resources\Observation-ABOBloodGroupObservationSNOMED021
D:\IG\0515_Final\build\fsh-generated\resources\Observation-ABORhObservationLOINC031
D:\IG\0515_Final\build\fsh-generated\resources\Observation-ABORhObservationSNOMED021
D:\IG\0515_Final\build\fsh-generated\resources\Observation-AlbuminObservation021
D:\IG\0515_Final\build\fsh-generated\resources\Observation-BasophilsObservation121
D:\IG\0515_Final\build\fsh-generated\resources\Observation-BodyHeight021
D:\IG\0515_Final\build\fsh-generated\resources\Observation-BodyWeight021
D:\IG\0515_Final\build\fsh-generated\resources\Observation-CMVDNAViralLoadCopiesmL051
D:\IG\0515_Final\build\fsh-generated\resources\Observation-CMVDNAViralLoadIUmL021
D:\IG\0515_Final\build\fsh-generated\resources\Observation-CMVIgAbPresenceSNOMED021
D:\IG\0515_Final\build\fsh-generated\resources\Observation-CMVIgGAbPresenceLOINC031
D:\IG\0515_Final\build\fsh-generated\resources\Observation-CMVIgMAbPresenceLOINC031
D:\IG\0515_Final\build\fsh-generated\resources\Observation-CMVIgMAbPresenceSNOMED021
D:\IG\0515_Final\build\fsh-generated\resources\Observation-Cytogenetics-Example-1031
D:\IG\0515_Final\build\fsh-generated\resources\Observation-EosinophilsObservation021
D:\IG\0515_Final\build\fsh-generated\resources\Observation-HemoglobinObservation021
D:\IG\0515_Final\build\fsh-generated\resources\Observation-LeukocytesObservation021
D:\IG\0515_Final\build\fsh-generated\resources\Observation-MetamyelocytesObservation031
D:\IG\0515_Final\build\fsh-generated\resources\Observation-NeutrophilsObservation021
D:\IG\0515_Final\build\fsh-generated\resources\Patient-PatientExample1022
D:\IG\0515_Final\build\fsh-generated\resources\Patient-PatientExample2012
D:\IG\0515_Final\build\fsh-generated\resources\Patient-PatientExample3033
D:\IG\0515_Final\build\fsh-generated\resources\Patient-PatientExample4033
D:\IG\0515_Final\build\fsh-generated\resources\Patient-PatientExample5035
D:\IG\0515_Final\build\fsh-generated\resources\Patient-PatientExample6021
D:\IG\0515_Final\build\fsh-generated\resources\StructureDefinition-cibmtr-additional-peri-transplant-medication032
D:\IG\0515_Final\build\fsh-generated\resources\StructureDefinition-cibmtr-ancestry230
D:\IG\0515_Final\build\fsh-generated\resources\StructureDefinition-cibmtr-cytogenetics025
D:\IG\0515_Final\build\fsh-generated\resources\StructureDefinition-cibmtr-gvhd-prophylaxis-medication031
D:\IG\0515_Final\build\fsh-generated\resources\StructureDefinition-cibmtr-medication022
D:\IG\0515_Final\build\fsh-generated\resources\StructureDefinition-cibmtr-medication-administration032
D:\IG\0515_Final\build\fsh-generated\resources\StructureDefinition-cibmtr-medication-request0153
D:\IG\0515_Final\build\fsh-generated\resources\StructureDefinition-cibmtr-medications0163
D:\IG\0515_Final\build\fsh-generated\resources\StructureDefinition-cibmtr-mobilizing-agent-medication031
D:\IG\0515_Final\build\fsh-generated\resources\StructureDefinition-cibmtr-obs-priority-variables0161
D:\IG\0515_Final\build\fsh-generated\resources\StructureDefinition-cibmtr-observation-lab0172
D:\IG\0515_Final\build\fsh-generated\resources\StructureDefinition-cibmtr-patient0114
D:\IG\0515_Final\build\fsh-generated\resources\StructureDefinition-cibmtr-post-hct-disease-therapy-planned-medication031
D:\IG\0515_Final\build\fsh-generated\resources\StructureDefinition-cibmtr-prep-regimen-medication031
D:\IG\0515_Final\build\fsh-generated\resources\StructureDefinition-cibmtr-prior-exposure-medication031
D:\IG\0515_Final\build\fsh-generated\resources\StructureDefinition-cibmtr-vital-signs0112
D:\IG\0515_Final\build\fsh-generated\resources\StructureDefinition-cibmtr-vital-signs-height092
D:\IG\0515_Final\build\fsh-generated\resources\StructureDefinition-cibmtr-vital-signs-weight092
D:\IG\0515_Final\build\fsh-generated\resources\ValueSet-cbc-w-differential-unspecified-blood-vs016
D:\IG\0515_Final\build\fsh-generated\resources\ValueSet-cibmtr-ancestry-vs210
D:\IG\0515_Final\build\fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-20210549
D:\IG\0515_Final\build\fsh-generated\resources\ValueSet-differential-unspecified-blood-vs0237
D:\IG\0515_Final\build\fsh-generated\resources\ValueSet-manual-differential-blood-vs0237

n/a Show Validation Information

warningUnable to find ImplementationGuide.definition.resource.description for the resource StructureDefinition/cibmtr-medications. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource StructureDefinition/cibmtr-observation-lab. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource StructureDefinition/cibmtr-patient. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warningUnable to find ImplementationGuide.definition.resource.description for the resource StructureDefinition/cibmtr-vital-signs. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
output\Access-Credentials​.html​#​/html​/body​/script at Line 710, column 2warningThe <script> containing the javascript '$(document).ready(fu'... is illegal and not allowed on the HL7 ci-build - need to put the script in a .js file in a trusted template if this IG is to build on the HL7 ci-build (if it is justified and needed) (also in 645 other files)
output\Access-Credentials​.html​#​/html​/body​/script at Line 753, column 2warningThe <script> containing the javascript 'anchors.options.visi'... is illegal and not allowed on the HL7 ci-build - need to put the script in a .js file in a trusted template if this IG is to build on the HL7 ci-build (if it is justified and needed) (also in 645 other files)
output\CodeSystem-cibmtr-ancestry-cs​.change​.history​.html​#​/html​/body​/script at Line 316, column 2warningThe <script> containing the javascript 'try { var currentTab'... is illegal and not allowed on the HL7 ci-build - need to put the script in a .js file in a trusted template if this IG is to build on the HL7 ci-build (if it is justified and needed) (also in 244 other files)
Connection-Guide-R4​.html​#​/html​/body​/div​/div​/div​/div​/div​/p​/a at Line 329, column 5errorThe link 'CRID-Assignment.html' for "Register patient and receive CRID" cannot be resolved HTML_LINK_CHECK_FAILED

fsh-generated\resources\CodeSystem-cibmtr-ancestry-cs.json Show Validation Information (1)

PathSeverityMessage
CodeSystem​.where(url = 'http:​/​/example​.org​/fhir​/CodeSystem​/cibmtr-ancestry')errorConformance resource D:\IG\0515_Final\build\fsh-generated\resources\CodeSystem-cibmtr-ancestry-cs.json - the canonical URL (http://fhir.nmdp.org/ig/cibmtr-reporting/CodeSystem/cibmtr-ancestry-cs) does not match the URL (http://example.org/fhir/CodeSystem/cibmtr-ancestry). Use the special-url parameter if you really mean for it not to match RESOURCE_CANONICAL_MISMATCH
CodeSysteminformationCodeSystems SHOULD have a stated value for the caseSensitive element so that users know the status and meaning of the code system clearly
CodeSystem (l1/c1249)warningPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.experimental is mandatory, but it is not present CODESYSTEM_SHAREABLE_MISSING
CodeSystem (l1/c1249)warningPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.caseSensitive is mandatory, but it is not present CODESYSTEM_SHAREABLE_MISSING
fsh-generated\resources\CodeSystem-cibmtr-ancestry-cserrorURL Mismatch http://fhir.nmdp.org/ig/cibmtr-reporting/CodeSystem/cibmtr-ancestry-cs vs http://example.org/fhir/CodeSystem/cibmtr-ancestry

fsh-generated\resources\ImplementationGuide-nmdp.fhir.cibmtr-reporting.json Show Validation Information (1)

PathSeverityMessage
ImplementationGuide​.dependsOn[2] (l1​/c2098)warningThe ImplementationGuide uses package hl7.fhir.us.core#8.0.0 released on 2025-06-10, but the most recent appropriate version is 9.0.0. This reference is getting old and the more recent version should be considered IG_DEPENDENCY_VERSION_WARNING_OLD
ImplementationGuide​.dependsOn[4] (l1​/c2442)warningThe ImplementationGuide uses package hl7.fhir.uv.genomics-reporting#2.0.0 released on 2022-05-09, but the most recent appropriate version is 3.0.0. This reference is getting old and the more recent version should be considered IG_DEPENDENCY_VERSION_WARNING_OLD

fsh-generated\resources\Medication-Medication-Cyclophosphamide-Example.json Show Validation Information (1)

PathSeverityMessage
Medication.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Medication.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Medication.code (l16/c4)warningA definition for CodeSystem 'http://www.nlm.nih.gov/research/umls/rxnorm' version '05052025' could not be found, so the code cannot be validated. Valid versions: 03022026 (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM_VERSION

fsh-generated\resources\Medication-Medication-Etoposide-Example.json Show Validation Information (1)

PathSeverityMessage
Medication.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Medication.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Medication.code (l16/c4)warningA definition for CodeSystem 'http://www.nlm.nih.gov/research/umls/rxnorm' version '05052025' could not be found, so the code cannot be validated. Valid versions: 03022026 (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM_VERSION

fsh-generated\resources\Medication-Medication-GVHD-Prophylaxis-Example.json Show Validation Information (1)

PathSeverityMessage
Medication.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Medication.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Medication.code (l16/c4)warningA definition for CodeSystem 'http://www.nlm.nih.gov/research/umls/rxnorm' version '05052025' could not be found, so the code cannot be validated. Valid versions: 03022026 (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM_VERSION

fsh-generated\resources\Medication-Medication-Mobilizing-Agent-Example.json Show Validation Information (1)

PathSeverityMessage
Medication.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Medication.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Medication.code (l16/c4)warningA definition for CodeSystem 'http://www.nlm.nih.gov/research/umls/rxnorm' version '05052025' could not be found, so the code cannot be validated. Valid versions: 03022026 (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM_VERSION

fsh-generated\resources\Medication-Medication-Peri-Transplant-Example.json Show Validation Information (1)

PathSeverityMessage
Medication.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Medication.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Medication.code (l16/c4)warningA definition for CodeSystem 'http://www.nlm.nih.gov/research/umls/rxnorm' version '05052025' could not be found, so the code cannot be validated. Valid versions: 03022026 (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM_VERSION

fsh-generated\resources\Medication-Medication-Post-HCT-Disease-Therapy-Example.json Show Validation Information (1)

PathSeverityMessage
Medication.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Medication.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Medication.code (l16/c4)warningA definition for CodeSystem 'http://www.nlm.nih.gov/research/umls/rxnorm' version '05052025' could not be found, so the code cannot be validated. Valid versions: 03022026 (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM_VERSION

fsh-generated\resources\Medication-Medication-Prep-Regimen-Example.json Show Validation Information (1)

PathSeverityMessage
Medication.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Medication.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Medication.code (l16/c4)warningA definition for CodeSystem 'http://www.nlm.nih.gov/research/umls/rxnorm' version '05052025' could not be found, so the code cannot be validated. Valid versions: 03022026 (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM_VERSION

fsh-generated\resources\Medication-Medication-PriorExposure-Example.json Show Validation Information (1)

PathSeverityMessage
Medication.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Medication.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Medication.code (l16/c4)warningA definition for CodeSystem 'http://www.nlm.nih.gov/research/umls/rxnorm' version '05052025' could not be found, so the code cannot be validated. Valid versions: 03022026 (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM_VERSION

fsh-generated\resources\MedicationAdministration-MedicationAdministration-Example1.json Show Validation Information (1)

PathSeverityMessage
MedicationAdministration​.meta​.security[0] (l6​/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
MedicationAdministration​.meta​.security[0] (l6​/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM

fsh-generated\resources\MedicationAdministration-MedicationAdministration-Example2.json Show Validation Information (1)

PathSeverityMessage
MedicationAdministration​.meta​.security[0] (l6​/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
MedicationAdministration​.meta​.security[0] (l6​/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
MedicationAdministration​.medication​.ofType(CodeableConcept) (l41​/c4)warningA definition for CodeSystem 'http://www.nlm.nih.gov/research/umls/rxnorm' version '05052025' could not be found, so the code cannot be validated. Valid versions: 03022026 (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM_VERSION

fsh-generated\resources\MedicationRequest-MedicationRequest-Etoposide-Example.json Show Validation Information (1)

PathSeverityMessage
MedicationRequest​.meta​.security[0] (l6​/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
MedicationRequest​.meta​.security[0] (l6​/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM

fsh-generated\resources\Observation-ABOBloodGroupObservationLOINC.json Show Validation Information (1)

PathSeverityMessage
Observation.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Observation.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Observation​.value​.ofType(CodeableConcept) (l36​/c4)warningConstraint failed: us-core-4: 'SHOULD use Snomed CT for coded Results (ofType(CodeableConcept).coding.system.empty() or (ofType(CodeableConcept).coding.system contains 'http://snomed.info/sct'))' (defined in http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab) (Best Practice Recommendation) http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab#us-core-4
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer

fsh-generated\resources\Observation-ABOBloodGroupObservationSNOMED.json Show Validation Information (1)

PathSeverityMessage
Observation.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Observation.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer

fsh-generated\resources\Observation-ABORhObservationLOINC.json Show Validation Information (1)

PathSeverityMessage
Observation.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Observation.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Observation​.value​.ofType(CodeableConcept) (l36​/c4)warningConstraint failed: us-core-4: 'SHOULD use Snomed CT for coded Results (ofType(CodeableConcept).coding.system.empty() or (ofType(CodeableConcept).coding.system contains 'http://snomed.info/sct'))' (defined in http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab) (Best Practice Recommendation) http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab#us-core-4
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer

fsh-generated\resources\Observation-ABORhObservationSNOMED.json Show Validation Information (1)

PathSeverityMessage
Observation.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Observation.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer

fsh-generated\resources\Observation-AlbuminObservation.json Show Validation Information (1)

PathSeverityMessage
Observation.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Observation.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer

fsh-generated\resources\Observation-BasophilsObservation.json Show Validation Information (1)

PathSeverityMessage
Observation.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Observation.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Observation.code (l27/c4)errorWrong Display Name 'Basophils/100 leukocytes in Blood' for http://loinc.org#30180-4. Valid display is one of 3 choices: 'Basophils/Leukocytes in Blood' (en-US), 'Basophils/Leukocytes in Blood' (en-US) or 'Basophils NFr Bld' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer

fsh-generated\resources\Observation-BodyHeight.json Show Validation Information (1)

PathSeverityMessage
Observation.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Observation.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer

fsh-generated\resources\Observation-BodyWeight.json Show Validation Information (1)

PathSeverityMessage
Observation.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Observation.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer

fsh-generated\resources\Observation-CMVDNAViralLoadCopiesmL.json Show Validation Information (1)

PathSeverityMessage
Observation.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Observation.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Observation​.value​.ofType(Quantity) (l36​/c4)warningUCUM Codes that contain human readable annotations like {copies} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked TYPE_SPECIFIC_CHECKS_DT_QTY_UCUM_ANNOTATIONS
Observation​.referenceRange[0]​.low (l44​/c8)warningUCUM Codes that contain human readable annotations like {copies} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked TYPE_SPECIFIC_CHECKS_DT_QTY_UCUM_ANNOTATIONS
Observation​.referenceRange[0]​.high (l50​/c8)warningUCUM Codes that contain human readable annotations like {copies} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked TYPE_SPECIFIC_CHECKS_DT_QTY_UCUM_ANNOTATIONS
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer

fsh-generated\resources\Observation-CMVDNAViralLoadIUmL.json Show Validation Information (1)

PathSeverityMessage
Observation.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Observation.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer

fsh-generated\resources\Observation-CMVIgAbPresenceSNOMED.json Show Validation Information (1)

PathSeverityMessage
Observation.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Observation.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer

fsh-generated\resources\Observation-CMVIgGAbPresenceLOINC.json Show Validation Information (1)

PathSeverityMessage
Observation.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Observation.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Observation​.value​.ofType(CodeableConcept) (l36​/c4)warningConstraint failed: us-core-4: 'SHOULD use Snomed CT for coded Results (ofType(CodeableConcept).coding.system.empty() or (ofType(CodeableConcept).coding.system contains 'http://snomed.info/sct'))' (defined in http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab) (Best Practice Recommendation) http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab#us-core-4
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer

fsh-generated\resources\Observation-CMVIgMAbPresenceLOINC.json Show Validation Information (1)

PathSeverityMessage
Observation.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Observation.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Observation​.value​.ofType(CodeableConcept) (l36​/c4)warningConstraint failed: us-core-4: 'SHOULD use Snomed CT for coded Results (ofType(CodeableConcept).coding.system.empty() or (ofType(CodeableConcept).coding.system contains 'http://snomed.info/sct'))' (defined in http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab) (Best Practice Recommendation) http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab#us-core-4
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer

fsh-generated\resources\Observation-CMVIgMAbPresenceSNOMED.json Show Validation Information (1)

PathSeverityMessage
Observation.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Observation.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer

fsh-generated\resources\Observation-Cytogenetics-Example-1.json Show Validation Information (1)

PathSeverityMessage
Observation.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Observation.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Observation​.component[0]​.value​.ofType(CodeableConcept) (l46​/c8)warningA definition for CodeSystem 'https://iscn.karger.com' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4) UNKNOWN_CODESYSTEM
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer

fsh-generated\resources\Observation-EosinophilsObservation.json Show Validation Information (1)

PathSeverityMessage
Observation.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Observation.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer

fsh-generated\resources\Observation-HemoglobinObservation.json Show Validation Information (1)

PathSeverityMessage
Observation.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Observation.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer

fsh-generated\resources\Observation-LeukocytesObservation.json Show Validation Information (1)

PathSeverityMessage
Observation.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Observation.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer

fsh-generated\resources\Observation-MetamyelocytesObservation.json Show Validation Information (1)

PathSeverityMessage
Observation.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Observation.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Observation​.value​.ofType(CodeableConcept) (l36​/c4)warningConstraint failed: us-core-4: 'SHOULD use Snomed CT for coded Results (ofType(CodeableConcept).coding.system.empty() or (ofType(CodeableConcept).coding.system contains 'http://snomed.info/sct'))' (defined in http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab) (Best Practice Recommendation) http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab#us-core-4
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer

fsh-generated\resources\Observation-NeutrophilsObservation.json Show Validation Information (1)

PathSeverityMessage
Observation.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Observation.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer

fsh-generated\resources\Patient-PatientExample1.json Show Validation Information (1)

PathSeverityMessage
Patient.identifier[0] (l17/c6)Slicing InformationThis element does not match any known slice defined in the profile http://fhir.nmdp.org/ig/cibmtr-reporting/StructureDefinition/cibmtr-patient|0.1.11 (this may not be a problem, but you should check that it's not intended to match a slice) Show Reasoning Details_for__matching_against_Profile_
Patient.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Patient.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Patient.identifier[1].system (l22/c64)warningNo definition could be found for URL value 'http://terminology.cibmtr.org/identifier/CRID' Type_Specific_Checks_DT_URL_Resolve

fsh-generated\resources\Patient-PatientExample2.json Show Validation Information (1)

PathSeverityMessage
Patient.identifier[0] (l17/c6)Slicing InformationThis element does not match any known slice defined in the profile http://fhir.nmdp.org/ig/cibmtr-reporting/StructureDefinition/cibmtr-patient|0.1.11 (this may not be a problem, but you should check that it's not intended to match a slice) Show Reasoning Details_for__matching_against_Profile_
Patient.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Patient.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM

fsh-generated\resources\Patient-PatientExample3.json Show Validation Information (1)

PathSeverityMessage
Patient.identifier[0] (l45/c6)Slicing InformationThis element does not match any known slice defined in the profile http://fhir.nmdp.org/ig/cibmtr-reporting/StructureDefinition/cibmtr-patient|0.1.11 (this may not be a problem, but you should check that it's not intended to match a slice) Show Reasoning Details_for__matching_against_Profile_
Patient.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Patient.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Patient​.extension[0]​.extension[1]​.value​.ofType(Coding) (l25​/c12)informationThe definition for the Code System with URI 'urn:oid:2.16.840.1.113883.6.238' doesn't provide any codes so the code cannot be validated TERMINOLOGY_TX_SYSTEM_NOT_USABLE
Patient.identifier[1].system (l50/c64)warningNo definition could be found for URL value 'http://terminology.cibmtr.org/identifier/CRID' Type_Specific_Checks_DT_URL_Resolve
Patient​.managingOrganization​.identifier​.system (l73​/c77)warningNo definition could be found for URL value 'http://terminology.cibmtr.org/identifier/transplant-center' Type_Specific_Checks_DT_URL_Resolve

fsh-generated\resources\Patient-PatientExample4.json Show Validation Information (1)

PathSeverityMessage
Patient.identifier[0] (l45/c6)Slicing InformationThis element does not match any known slice defined in the profile http://fhir.nmdp.org/ig/cibmtr-reporting/StructureDefinition/cibmtr-patient|0.1.11 (this may not be a problem, but you should check that it's not intended to match a slice) Show Reasoning Details_for__matching_against_Profile_
Patient.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Patient.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Patient​.extension[0]​.extension[1]​.value​.ofType(Coding) (l25​/c12)informationThe definition for the Code System with URI 'urn:oid:2.16.840.1.113883.6.238' doesn't provide any codes so the code cannot be validated TERMINOLOGY_TX_SYSTEM_NOT_USABLE
Patient.identifier[1].system (l50/c64)warningNo definition could be found for URL value 'http://terminology.cibmtr.org/identifier/CRID' Type_Specific_Checks_DT_URL_Resolve
Patient​.managingOrganization​.identifier​.system (l75​/c77)warningNo definition could be found for URL value 'http://terminology.cibmtr.org/identifier/transplant-center' Type_Specific_Checks_DT_URL_Resolve

fsh-generated\resources\Patient-PatientExample5.json Show Validation Information (1)

PathSeverityMessage
Patient.identifier[0] (l61/c6)Slicing InformationThis element does not match any known slice defined in the profile http://fhir.nmdp.org/ig/cibmtr-reporting/StructureDefinition/cibmtr-patient|0.1.11 (this may not be a problem, but you should check that it's not intended to match a slice) Show Reasoning Details_for__matching_against_Profile_
Patient.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Patient.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Patient​.extension[0]​.extension[1]​.value​.ofType(Coding) (l25​/c12)informationThe definition for the Code System with URI 'urn:oid:2.16.840.1.113883.6.238' doesn't provide any codes so the code cannot be validated TERMINOLOGY_TX_SYSTEM_NOT_USABLE
Patient​.extension[0]​.extension[2]​.value​.ofType(Coding) (l33​/c12)informationThe definition for the Code System with URI 'urn:oid:2.16.840.1.113883.6.238' doesn't provide any codes so the code cannot be validated TERMINOLOGY_TX_SYSTEM_NOT_USABLE
Patient​.extension[1]​.extension[1]​.value​.ofType(Coding) (l50​/c12)informationThe definition for the Code System with URI 'urn:oid:2.16.840.1.113883.6.238' doesn't provide any codes so the code cannot be validated TERMINOLOGY_TX_SYSTEM_NOT_USABLE
Patient.identifier[1].system (l66/c64)warningNo definition could be found for URL value 'http://terminology.cibmtr.org/identifier/CRID' Type_Specific_Checks_DT_URL_Resolve
Patient​.managingOrganization​.identifier​.system (l90​/c77)warningNo definition could be found for URL value 'http://terminology.cibmtr.org/identifier/transplant-center' Type_Specific_Checks_DT_URL_Resolve

fsh-generated\resources\Patient-PatientExample6.json Show Validation Information (1)

PathSeverityMessage
Patient.meta.security[0] (l6/c8)informationReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0 (from https://tx.fhir.org/r4, see log, or see the servers logic) MSG_RETIRED
Patient.meta.security[0] (l6/c8)warningA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4, see log, or see the servers logic) UNKNOWN_CODESYSTEM
Patient.identifier[0].system (l28/c64)warningNo definition could be found for URL value 'http://terminology.cibmtr.org/identifier/CRID' Type_Specific_Checks_DT_URL_Resolve

fsh-generated\resources\StructureDefinition-cibmtr-additional-peri-transplant-medication.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.snapshot​.element[20]​.binding​.extension[0] (l1​/c39498)informationThe extension http://hl7.org/fhir/StructureDefinition/elementdefinition-maxValueSet|5.3.0 is deprecated with the note: 'Use additionalBinding extension or element instead' MSG_DEPENDS_ON_DEPRECATED_NOTE
StructureDefinition​.snapshot​.element[26]​.binding​.valueSet (l1​/c48608)warningThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240606', found versions: 20170601 (from us.nlm.vsac#0.11.0), 20240606 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4|20240606' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[1]​.bindingwarningThe definition for the element 'Medication.code.coding' binds to the value set 'http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/med-addition-peri-transplant-vs' which is experimental, but this structure is not labeled as experimental SD_ED_EXPERIMENTAL_BINDING
StructureDefinition​.snapshot​.element[9]​.slicing​.discriminator[0] (l1​/c23873)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.snapshot​.element[29]​.bindingwarningThe definition for the element 'Medication.code.coding' binds to the value set 'http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/med-addition-peri-transplant-vs' which is experimental, but this structure is not labeled as experimental SD_ED_EXPERIMENTAL_BINDING

fsh-generated\resources\StructureDefinition-cibmtr-ancestry.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.where(url = 'http:​/​/example​.org​/fhir​/StructureDefinition​/cibmtr-ancestry')errorConformance resource D:\IG\0515_Final\build\fsh-generated\resources\StructureDefinition-cibmtr-ancestry.json - the canonical URL (http://fhir.nmdp.org/ig/cibmtr-reporting/StructureDefinition/cibmtr-ancestry) does not match the URL (http://example.org/fhir/StructureDefinition/cibmtr-ancestry). Use the special-url parameter if you really mean for it not to match RESOURCE_CANONICAL_MISMATCH
StructureDefinition​.snapshot​.element[3]​.type[0]​.profile[0] (l1​/c27220)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-race'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-race' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-race|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[1]​.type[0]​.profile[0] (l1​/c34921)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-race'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-race' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-race|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.where(url = 'http:​/​/example​.org​/fhir​/StructureDefinition​/cibmtr-ancestry')warningThe Implementation Guide contains no examples for this extension
fsh-generated\resources\StructureDefinition-cibmtr-ancestryerrorURL Mismatch http://fhir.nmdp.org/ig/cibmtr-reporting/StructureDefinition/cibmtr-ancestry vs http://example.org/fhir/StructureDefinition/cibmtr-ancestry

fsh-generated\resources\StructureDefinition-cibmtr-cytogenetics.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.snapshot​.element[24]​.type[0]​.profile[0] (l1​/c71079)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/observation-secondaryFinding'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 1.0.0 (from hl7.fhir.uv.extensions.r4#1.0.0), 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.1.0-cibuild (from hl7.fhir.uv.extensions.r4#5.1.0-snapshot1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/observation-secondaryFinding' to 'http://hl7.org/fhir/StructureDefinition/observation-secondaryFinding|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[25]​.type[0]​.profile[0] (l1​/c72190)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/bodySite'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 1.0.0 (from hl7.fhir.uv.extensions.r4#1.0.0), 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.1.0-cibuild (from hl7.fhir.uv.extensions.r4#5.1.0-snapshot1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/bodySite' to 'http://hl7.org/fhir/StructureDefinition/bodySite|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[1]​.slicing​.discriminator[0] (l1​/c581655)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.snapshot​.element[9]​.slicing​.discriminator[0] (l1​/c50397)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
Observation.extension (l1/c71079)informationThe extension http://hl7.org/fhir/StructureDefinition/observation-secondaryFinding|5.3.0 is deprecated with the note: 'This extension is deprecated - use the [[[http://hl7.org/fhir/StructureDefinition/observation-structure-type]]] instead' MSG_DEPENDS_ON_DEPRECATED_NOTE
StructureDefinition​.snapshot​.element[35]​.pattern​.ofType(Coding)informationThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users)
StructureDefinition​.snapshot​.element[66]​.slicing​.discriminator[0] (l1​/c132867)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED

fsh-generated\resources\StructureDefinition-cibmtr-gvhd-prophylaxis-medication.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.snapshot​.element[26]​.binding​.valueSet (l1​/c48285)warningThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240606', found versions: 20170601 (from us.nlm.vsac#0.11.0), 20240606 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4|20240606' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[1]​.bindingwarningThe definition for the element 'Medication.code.coding' binds to the value set 'http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/med-gvhd-prophylaxis-vs' which is experimental, but this structure is not labeled as experimental SD_ED_EXPERIMENTAL_BINDING
StructureDefinition​.snapshot​.element[9]​.slicing​.discriminator[0] (l1​/c23550)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.snapshot​.element[29]​.bindingwarningThe definition for the element 'Medication.code.coding' binds to the value set 'http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/med-gvhd-prophylaxis-vs' which is experimental, but this structure is not labeled as experimental SD_ED_EXPERIMENTAL_BINDING

fsh-generated\resources\StructureDefinition-cibmtr-medication.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.baseDefinition (l1​/c18211)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medication'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medication' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medication|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[26]​.binding​.valueSet (l1​/c54680)warningThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240606', found versions: 20170601 (from us.nlm.vsac#0.11.0), 20240606 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4|20240606' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[1]​.slicing​.discriminator[0] (l1​/c77147)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.snapshot​.element[9]​.slicing​.discriminator[0] (l1​/c29945)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED

fsh-generated\resources\StructureDefinition-cibmtr-medication-administration.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.snapshot​.element[33]​.binding​.valueSet (l1​/c64664)warningThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240606', found versions: 20170601 (from us.nlm.vsac#0.11.0), 20240606 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4|20240606' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[45]​.type[0]​.targetProfile[0] (l1​/c78918)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-condition-problems-health-concerns'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-condition-problems-health-concerns' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-condition-problems-health-concerns|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[1]​.slicing​.discriminator[0] (l1​/c97972)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.snapshot​.element[9]​.slicing​.discriminator[0] (l1​/c32273)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.snapshot (l1​/c97719)warningThe slice 'normalizationBasis' on path 'MedicationAdministration.extension' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true

fsh-generated\resources\StructureDefinition-cibmtr-medication-request.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.snapshot​.element[0]​.constraint[5]​.source (l1​/c23933)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medicationrequest'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medicationrequest' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medicationrequest|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[35]​.type[1]​.targetProfile[0] (l1​/c70463)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[35]​.type[1]​.targetProfile[1] (l1​/c70534)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[35]​.type[1]​.targetProfile[2] (l1​/c70600)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[35]​.type[1]​.targetProfile[3] (l1​/c70675)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitionerrole'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitionerrole' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitionerrole|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[35]​.type[1]​.targetProfile[4] (l1​/c70747)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[36]​.type[1]​.targetProfile[0] (l1​/c72901)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medication'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medication' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medication|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[36]​.binding​.valueSet (l1​/c73331)warningThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240606', found versions: 20170601 (from us.nlm.vsac#0.11.0), 20240606 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4|20240606' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[38]​.type[0]​.targetProfile[0] (l1​/c76362)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-encounter'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-encounter' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-encounter|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[41]​.type[0]​.targetProfile[0] (l1​/c79973)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[41]​.type[0]​.targetProfile[1] (l1​/c80044)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[46]​.type[0]​.targetProfile[0] (l1​/c86737)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-condition-problems-health-concerns'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-condition-problems-health-concerns' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-condition-problems-health-concerns|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[96]​.binding​.valueSet (l1​/c152998)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-ActSubstanceAdminSubstitutionCode'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.2.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-ActSubstanceAdminSubstitutionCode' to 'http://terminology.hl7.org/ValueSet/v3-ActSubstanceAdminSubstitutionCode|3.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[97]​.binding​.valueSet (l1​/c154318)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-SubstanceAdminSubstitutionReason'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.2.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-SubstanceAdminSubstitutionReason' to 'http://terminology.hl7.org/ValueSet/v3-SubstanceAdminSubstitutionReason|3.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[1]​.slicing​.discriminator[0] (l1​/c158409)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.snapshot​.element[9]​.slicing​.discriminator[0] (l1​/c33871)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.snapshot​.element[31]​.slicing​.discriminator[0] (l1​/c64267)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.snapshot (l1​/c158184)warningThe slice 'normalizationBasis' on path 'MedicationRequest.extension' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true

fsh-generated\resources\StructureDefinition-cibmtr-medications.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.snapshot​.element[0]​.constraint[5]​.source (l1​/c23793)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medicationrequest'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medicationrequest' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medicationrequest|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[35]​.type[1]​.targetProfile[0] (l1​/c70316)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[35]​.type[1]​.targetProfile[1] (l1​/c70387)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[35]​.type[1]​.targetProfile[2] (l1​/c70453)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[35]​.type[1]​.targetProfile[3] (l1​/c70528)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitionerrole'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitionerrole' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitionerrole|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[35]​.type[1]​.targetProfile[4] (l1​/c70600)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[36]​.type[1]​.targetProfile[0] (l1​/c72754)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medication'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medication' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medication|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[36]​.binding​.valueSet (l1​/c73184)warningThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240606', found versions: 20170601 (from us.nlm.vsac#0.11.0), 20240606 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4|20240606' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[38]​.type[0]​.targetProfile[0] (l1​/c76215)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-encounter'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-encounter' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-encounter|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[41]​.type[0]​.targetProfile[0] (l1​/c79826)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[41]​.type[0]​.targetProfile[1] (l1​/c79897)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[46]​.type[0]​.targetProfile[0] (l1​/c86590)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-condition-problems-health-concerns'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-condition-problems-health-concerns' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-condition-problems-health-concerns|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[96]​.binding​.valueSet (l1​/c152851)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-ActSubstanceAdminSubstitutionCode'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.2.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-ActSubstanceAdminSubstitutionCode' to 'http://terminology.hl7.org/ValueSet/v3-ActSubstanceAdminSubstitutionCode|3.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[97]​.binding​.valueSet (l1​/c154171)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-SubstanceAdminSubstitutionReason'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.2.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-SubstanceAdminSubstitutionReason' to 'http://terminology.hl7.org/ValueSet/v3-SubstanceAdminSubstitutionReason|3.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[1]​.slicing​.discriminator[0] (l1​/c158262)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.snapshot​.element[9]​.slicing​.discriminator[0] (l1​/c33731)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.snapshot​.element[31]​.slicing​.discriminator[0] (l1​/c64120)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.snapshot (l1​/c158037)warningThe slice 'normalizationBasis' on path 'MedicationRequest.extension' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
StructureDefinition​.where(url = 'http:​/​/fhir​.nmdp​.org​/ig​/cibmtr-reporting​/StructureDefinition​/cibmtr-medications')warningThe Implementation Guide contains no examples for this profile

fsh-generated\resources\StructureDefinition-cibmtr-mobilizing-agent-medication.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.snapshot​.element[26]​.binding​.valueSet (l1​/c48314)warningThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240606', found versions: 20170601 (from us.nlm.vsac#0.11.0), 20240606 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4|20240606' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[1]​.bindingwarningThe definition for the element 'Medication.code.coding' binds to the value set 'http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/med-mobilizing-agents-vs' which is experimental, but this structure is not labeled as experimental SD_ED_EXPERIMENTAL_BINDING
StructureDefinition​.snapshot​.element[9]​.slicing​.discriminator[0] (l1​/c23579)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.snapshot​.element[29]​.bindingwarningThe definition for the element 'Medication.code.coding' binds to the value set 'http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/med-mobilizing-agents-vs' which is experimental, but this structure is not labeled as experimental SD_ED_EXPERIMENTAL_BINDING

fsh-generated\resources\StructureDefinition-cibmtr-obs-priority-variables.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.snapshot​.element[0]​.constraint[7]​.source (l1​/c17076)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[30]​.binding​.valueSet (l1​/c56556)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/ValueSet/us-core-clinical-result-observation-category'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/ValueSet/us-core-clinical-result-observation-category' to 'http://hl7.org/fhir/us/core/ValueSet/us-core-clinical-result-observation-category|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[31]​.binding​.valueSet (l1​/c58110)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/ValueSet/us-core-laboratory-test-codes'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/ValueSet/us-core-laboratory-test-codes' to 'http://hl7.org/fhir/us/core/ValueSet/us-core-laboratory-test-codes|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[36]​.type[0]​.targetProfile[0] (l1​/c64827)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[36]​.type[0]​.targetProfile[3] (l1​/c64991)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-location'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-location' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-location|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[38]​.type[0]​.targetProfile[0] (l1​/c68922)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-encounter'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-encounter' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-encounter|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[39]​.constraint[1]​.source (l1​/c71373)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[41]​.type[0]​.targetProfile[0] (l1​/c73540)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[41]​.type[0]​.targetProfile[1] (l1​/c73611)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[41]​.type[0]​.targetProfile[2] (l1​/c73677)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[41]​.type[0]​.targetProfile[4] (l1​/c73803)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[41]​.type[0]​.targetProfile[5] (l1​/c73875)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[42]​.constraint[1]​.source (l1​/c77580)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[42]​.constraint[2]​.source (l1​/c78148)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[48]​.type[0]​.targetProfile[0] (l1​/c86334)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-specimen'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-specimen' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-specimen|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[50]​.constraint[2]​.source (l1​/c89769)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[9]​.slicing​.discriminator[0] (l1​/c25340)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED

fsh-generated\resources\StructureDefinition-cibmtr-observation-lab.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.baseDefinition (l1​/c25873)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[0]​.constraint[7]​.source (l1​/c30872)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[30]​.binding​.valueSet (l1​/c70352)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/ValueSet/us-core-clinical-result-observation-category'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/ValueSet/us-core-clinical-result-observation-category' to 'http://hl7.org/fhir/us/core/ValueSet/us-core-clinical-result-observation-category|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[31]​.binding​.valueSet (l1​/c71906)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/ValueSet/us-core-laboratory-test-codes'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/ValueSet/us-core-laboratory-test-codes' to 'http://hl7.org/fhir/us/core/ValueSet/us-core-laboratory-test-codes|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[36]​.type[0]​.targetProfile[0] (l1​/c78493)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[36]​.type[0]​.targetProfile[3] (l1​/c78657)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-location'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-location' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-location|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[38]​.type[0]​.targetProfile[0] (l1​/c82588)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-encounter'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-encounter' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-encounter|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[39]​.constraint[1]​.source (l1​/c85039)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[41]​.type[0]​.targetProfile[0] (l1​/c87206)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[41]​.type[0]​.targetProfile[1] (l1​/c87277)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[41]​.type[0]​.targetProfile[2] (l1​/c87343)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[41]​.type[0]​.targetProfile[4] (l1​/c87469)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[41]​.type[0]​.targetProfile[5] (l1​/c87541)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[42]​.constraint[1]​.source (l1​/c91246)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[42]​.constraint[2]​.source (l1​/c91814)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[48]​.type[0]​.targetProfile[0] (l1​/c100000)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-specimen'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-specimen' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-specimen|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[50]​.constraint[2]​.source (l1​/c103435)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[1]​.slicing​.discriminator[0] (l1​/c133822)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.snapshot​.element[9]​.slicing​.discriminator[0] (l1​/c39136)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED

fsh-generated\resources\StructureDefinition-cibmtr-patient.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.baseDefinition (l1​/c54686)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[24]​.type[0]​.profile[0] (l1​/c86357)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-race'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-race' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-race|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[25]​.type[0]​.profile[0] (l1​/c88491)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-ethnicity'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-ethnicity' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-ethnicity|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[26]​.type[0]​.profile[0] (l1​/c89777)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-tribal-affiliation'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-tribal-affiliation' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-tribal-affiliation|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[27]​.type[0]​.profile[0] (l1​/c90983)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-sex'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-sex' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-sex|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[29]​.type[0]​.profile[0] (l1​/c93360)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 1.0.0 (from hl7.fhir.uv.extensions.r4#1.0.0), 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.1.0-cibuild (from hl7.fhir.uv.extensions.r4#5.1.0-snapshot1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName' to 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[30]​.type[0]​.profile[0] (l1​/c94564)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/patient-birthPlace'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 1.0.0 (from hl7.fhir.uv.extensions.r4#1.0.0), 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.1.0-cibuild (from hl7.fhir.uv.extensions.r4#5.1.0-snapshot1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/patient-birthPlace' to 'http://hl7.org/fhir/StructureDefinition/patient-birthPlace|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[98]​.constraint[1]​.source (l1​/c180841)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[128]​.binding​.valueSet (l1​/c216574)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/USPS-State'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '2.0.0', found versions: 1.0.0 (from hl7.terminology.r4#6.4.0), 2.0.0 (from hl7.terminology.r4#7.2.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/USPS-State' to 'http://terminology.hl7.org/ValueSet/USPS-State|2.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[5]​.type[0]​.profile[0] (l1​/c257664)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 1.0.0 (from hl7.fhir.uv.extensions.r4#1.0.0), 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.1.0-cibuild (from hl7.fhir.uv.extensions.r4#5.1.0-snapshot1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName' to 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[6]​.type[0]​.profile[0] (l1​/c257906)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/patient-birthPlace'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 1.0.0 (from hl7.fhir.uv.extensions.r4#1.0.0), 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.1.0-cibuild (from hl7.fhir.uv.extensions.r4#5.1.0-snapshot1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/patient-birthPlace' to 'http://hl7.org/fhir/StructureDefinition/patient-birthPlace|5.3.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[1]​.slicing​.discriminator[0] (l1​/c256720)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.differential​.element[7]​.slicing​.discriminator[0] (l1​/c258047)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.snapshot​.element[9]​.slicing​.discriminator[0] (l1​/c66224)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.snapshot​.element[32]​.slicing​.discriminator[0] (l1​/c97903)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED

fsh-generated\resources\StructureDefinition-cibmtr-post-hct-disease-therapy-planned-medication.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.snapshot​.element[26]​.binding​.valueSet (l1​/c48506)warningThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240606', found versions: 20170601 (from us.nlm.vsac#0.11.0), 20240606 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4|20240606' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[1]​.bindingwarningThe definition for the element 'Medication.code.coding' binds to the value set 'http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/med-post-hct-disease-therapy-planned-vs' which is experimental, but this structure is not labeled as experimental SD_ED_EXPERIMENTAL_BINDING
StructureDefinition​.snapshot​.element[9]​.slicing​.discriminator[0] (l1​/c23771)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.snapshot​.element[29]​.bindingwarningThe definition for the element 'Medication.code.coding' binds to the value set 'http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/med-post-hct-disease-therapy-planned-vs' which is experimental, but this structure is not labeled as experimental SD_ED_EXPERIMENTAL_BINDING

fsh-generated\resources\StructureDefinition-cibmtr-prep-regimen-medication.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.snapshot​.element[26]​.binding​.valueSet (l1​/c48259)warningThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240606', found versions: 20170601 (from us.nlm.vsac#0.11.0), 20240606 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4|20240606' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[1]​.bindingwarningThe definition for the element 'Medication.code.coding' binds to the value set 'http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/med-prep-regimen-vs' which is experimental, but this structure is not labeled as experimental SD_ED_EXPERIMENTAL_BINDING
StructureDefinition​.snapshot​.element[9]​.slicing​.discriminator[0] (l1​/c23524)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.snapshot​.element[29]​.bindingwarningThe definition for the element 'Medication.code.coding' binds to the value set 'http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/med-prep-regimen-vs' which is experimental, but this structure is not labeled as experimental SD_ED_EXPERIMENTAL_BINDING

fsh-generated\resources\StructureDefinition-cibmtr-prior-exposure-medication.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.snapshot​.element[26]​.binding​.valueSet (l1​/c48315)warningThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240606', found versions: 20170601 (from us.nlm.vsac#0.11.0), 20240606 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4|20240606' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[1]​.bindingwarningThe definition for the element 'Medication.code.coding' binds to the value set 'http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/med-prior-exposure-vs' which is experimental, but this structure is not labeled as experimental SD_ED_EXPERIMENTAL_BINDING
StructureDefinition​.snapshot​.element[9]​.slicing​.discriminator[0] (l1​/c23580)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.snapshot​.element[29]​.bindingwarningThe definition for the element 'Medication.code.coding' binds to the value set 'http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/med-prior-exposure-vs' which is experimental, but this structure is not labeled as experimental SD_ED_EXPERIMENTAL_BINDING

fsh-generated\resources\StructureDefinition-cibmtr-vital-signs.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.baseDefinition (l1​/c22724)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[42]​.binding​.valueSet (l1​/c82049)warningA definition could not be found for Canonical URL 'https://vsac.nlm.nih.gov/valueset/2.16.840.1.113762.1.4.1295.1/expansion' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVE
StructureDefinition​.snapshot​.element[43]​.type[0]​.targetProfile[0] (l1​/c83467)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[48]​.type[0]​.targetProfile[0] (l1​/c91102)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[48]​.type[0]​.targetProfile[1] (l1​/c91173)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[48]​.type[0]​.targetProfile[2] (l1​/c91239)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[48]​.type[0]​.targetProfile[4] (l1​/c91365)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[48]​.type[0]​.targetProfile[5] (l1​/c91437)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[73]​.binding​.valueSet (l1​/c128866)warningThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240322', found versions: 20210630 (from us.nlm.vsac#0.11.0), 20240322 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62|20240322' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[5]​.binding​.valueSet (l1​/c137524)warningA definition could not be found for Canonical URL 'https://vsac.nlm.nih.gov/valueset/2.16.840.1.113762.1.4.1295.1/expansion' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVE
StructureDefinition​.differential​.element[1]​.slicing​.discriminator[0] (l1​/c136600)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.snapshot​.element[9]​.slicing​.discriminator[0] (l1​/c35940)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.where(url = 'http:​/​/fhir​.nmdp​.org​/ig​/cibmtr-reporting​/StructureDefinition​/cibmtr-vital-signs')warningThe Implementation Guide contains no examples for this profile

fsh-generated\resources\StructureDefinition-cibmtr-vital-signs-height.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.baseDefinition (l1​/c23756)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-body-height'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-body-height' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-body-height|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[42]​.binding​.valueSet (l1​/c83191)warningThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240322', found versions: 20210630 (from us.nlm.vsac#0.11.0), 20240322 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62|20240322' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[43]​.type[0]​.targetProfile[0] (l1​/c84609)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[48]​.type[0]​.targetProfile[0] (l1​/c92244)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[48]​.type[0]​.targetProfile[1] (l1​/c92315)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[48]​.type[0]​.targetProfile[2] (l1​/c92381)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[48]​.type[0]​.targetProfile[4] (l1​/c92507)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[48]​.type[0]​.targetProfile[5] (l1​/c92579)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[81]​.binding​.valueSet (l1​/c140127)warningThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240322', found versions: 20210630 (from us.nlm.vsac#0.11.0), 20240322 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62|20240322' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[1]​.slicing​.discriminator[0] (l1​/c147861)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.snapshot​.element[9]​.slicing​.discriminator[0] (l1​/c36972)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED

fsh-generated\resources\StructureDefinition-cibmtr-vital-signs-weight.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.baseDefinition (l1​/c23756)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-body-weight'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-body-weight' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-body-weight|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[42]​.binding​.valueSet (l1​/c83192)warningThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240322', found versions: 20210630 (from us.nlm.vsac#0.11.0), 20240322 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62|20240322' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[43]​.type[0]​.targetProfile[0] (l1​/c84610)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[48]​.type[0]​.targetProfile[0] (l1​/c92245)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[48]​.type[0]​.targetProfile[1] (l1​/c92316)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[48]​.type[0]​.targetProfile[2] (l1​/c92382)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[48]​.type[0]​.targetProfile[4] (l1​/c92508)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[48]​.type[0]​.targetProfile[5] (l1​/c92580)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson|8.0.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[81]​.binding​.valueSet (l1​/c140128)warningThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240322', found versions: 20210630 (from us.nlm.vsac#0.11.0), 20240322 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62|20240322' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[1]​.slicing​.discriminator[0] (l1​/c147862)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.snapshot​.element[9]​.slicing​.discriminator[0] (l1​/c36972)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED

fsh-generated\resources\ValueSet-cbc-w-differential-unspecified-blood-vs.json Show Validation Information (1)

PathSeverityMessage
ValueSet​.compose​.include[0]​.concept[0] (l1​/c2866)informationWrong Display Name 'Hematocrit [Volume Fraction] of Blood' for http://loinc.org#20570-8. Valid display is one of 3 choices: 'Hematocrit [Volume Fraction] of Blood by calculation' (en-US), 'Hematocrit [Volume Fraction] of Blood by calculation' (en-US) or 'Hct VFr Bld Calc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[5] (l1​/c3154)informationWrong Display Name 'MCHC [Mass/volume]' for http://loinc.org#28540-3. Valid display is one of 3 choices: 'MCHC [Entitic Mass/volume] in Red Blood Cells' (en-US), 'MCHC [Entitic Mass/volume] in Red Blood Cells' (en-US) or 'MCHC RBC-EntMCnc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[6] (l1​/c3232)informationWrong Display Name 'Platelet mean volume [Entitic volume] in Blood' for http://loinc.org#28542-9. Valid display is one of 3 choices: 'Platelet [Entitic mean volume] in Blood' (en-US), 'Platelet [Entitic mean volume] in Blood' (en-US) or 'PMV Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[7] (l1​/c3311)informationWrong Display Name 'Erythrocyte distribution width [Entitic volume]' for http://loinc.org#30384-2. Valid display is one of 3 choices: 'Deprecated Erythrocyte distribution width [Entitic volume]' (en-US), 'Deprecated Erythrocyte distribution width [Entitic volume]' (en-US) or 'Deprecated RDW RBC' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[7] (l1​/c3311)warningThe concept '30384-2' is deprecated and its use should be reviewed (from https://tx.fhir.org/r4, see log) DEPRECATED_CONCEPT_FOUND
ValueSet​.compose​.include[0]​.concept[8] (l1​/c3381)informationWrong Display Name 'Erythrocyte distribution width [Ratio]' for http://loinc.org#30385-9. Valid display is one of 3 choices: 'Erythrocyte [DistWidth] in Blood' (en-US), 'Erythrocyte [DistWidth] in Blood' (en-US) or 'Erythrocyte DistWidth Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[9] (l1​/c3433)informationWrong Display Name 'MCV [Entitic volume]' for http://loinc.org#30428-7. Valid display is one of 3 choices: 'MCV [Entitic mean volume] in Red Blood Cells' (en-US), 'MCV [Entitic mean volume] in Red Blood Cells' (en-US) or 'MCV RBC' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT

fsh-generated\resources\ValueSet-cibmtr-ancestry-vs.json Show Validation Information (1)

PathSeverityMessage
ValueSet​.where(url = 'https:​/​/termservices​.nmdp​.org​/atlas​/​#​/conceptset​/136​/expression')errorConformance resource D:\IG\0515_Final\build\fsh-generated\resources\ValueSet-cibmtr-ancestry-vs.json - the canonical URL (http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/cibmtr-ancestry-vs) does not match the URL (https://termservices.nmdp.org/atlas/#/conceptset/136/expression). Use the special-url parameter if you really mean for it not to match RESOURCE_CANONICAL_MISMATCH
ValueSet (l1/c1248)warningPublished value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
fsh-generated\resources\ValueSet-cibmtr-ancestry-vserrorURL Mismatch http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/cibmtr-ancestry-vs vs https://termservices.nmdp.org/atlas/#/conceptset/136/expression

fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.json Show Validation Information (1)

PathSeverityMessage
ValueSet​.compose​.include[0]​.concept[0] (l1​/c19849)informationWrong Display Name 'Band form neutrophils/100 leukocytes in Blood' for http://loinc.org#26508-2. Valid display is one of 3 choices: 'Band form neutrophils/Leukocytes in Blood' (en-US), 'Band form neutrophils/Leukocytes in Blood' (en-US) or 'Neuts Band NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[1] (l1​/c19945)informationWrong Display Name 'Band form neutrophils/100 leukocytes in Blood by Automated count' for http://loinc.org#35332-6. Valid display is one of 3 choices: 'Band form neutrophils/Leukocytes in Blood by Automated count' (en-US), 'Band form neutrophils/Leukocytes in Blood by Automated count' (en-US) or 'Neuts Band NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[2] (l1​/c20036)informationWrong Display Name 'Band form neutrophils/100 leukocytes in Blood by Manual count' for http://loinc.org#764-1. Valid display is one of 3 choices: 'Band form neutrophils/Leukocytes in Blood by Manual count' (en-US), 'Band form neutrophils/Leukocytes in Blood by Manual count' (en-US) or 'Neuts Band NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[3] (l1​/c20101)informationWrong Display Name 'Basophils/100 leukocytes in Blood' for http://loinc.org#30180-4. Valid display is one of 3 choices: 'Basophils/Leukocytes in Blood' (en-US), 'Basophils/Leukocytes in Blood' (en-US) or 'Basophils NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[4] (l1​/c20183)informationWrong Display Name 'Basophils/100 leukocytes in Blood by Automated count' for http://loinc.org#706-2. Valid display is one of 3 choices: 'Basophils/Leukocytes in Blood by Automated count' (en-US), 'Basophils/Leukocytes in Blood by Automated count' (en-US) or 'Basophils NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[5] (l1​/c20262)informationWrong Display Name 'Basophils/100 leukocytes in Blood by Manual count' for http://loinc.org#707-0. Valid display is one of 3 choices: 'Basophils/Leukocytes in Blood by Manual count' (en-US), 'Basophils/Leukocytes in Blood by Manual count' (en-US) or 'Basophils NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[6] (l1​/c20324)informationWrong Display Name 'Blasts/100 leukocytes in Blood' for http://loinc.org#26446-5. Valid display is one of 3 choices: 'Blasts/Leukocytes in Blood' (en-US), 'Blasts/Leukocytes in Blood' (en-US) or 'Blasts NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[7] (l1​/c20400)informationWrong Display Name 'Blasts/100 leukocytes in Blood by Manual count' for http://loinc.org#709-6. Valid display is one of 3 choices: 'Blasts/Leukocytes in Blood by Manual count' (en-US), 'Blasts/Leukocytes in Blood by Manual count' (en-US) or 'Blasts NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[11] (l1​/c20687)informationWrong Display Name 'Eosinophils/100 leukocytes in Blood' for http://loinc.org#26450-7. Valid display is one of 3 choices: 'Eosinophils/Leukocytes in Blood' (en-US), 'Eosinophils/Leukocytes in Blood' (en-US) or 'Eosinophil NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[12] (l1​/c20771)informationWrong Display Name 'Eosinophils/100 leukocytes in Blood by Automated count' for http://loinc.org#713-8. Valid display is one of 3 choices: 'Eosinophils/Leukocytes in Blood by Automated count' (en-US), 'Eosinophils/Leukocytes in Blood by Automated count' (en-US) or 'Eosinophil NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[13] (l1​/c20852)informationWrong Display Name 'Eosinophils/100 leukocytes in Blood by Manual count' for http://loinc.org#714-6. Valid display is one of 3 choices: 'Eosinophils/Leukocytes in Blood by Manual count' (en-US), 'Eosinophils/Leukocytes in Blood by Manual count' (en-US) or 'Eosinophil NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[34] (l1​/c22603)informationWrong Display Name 'Hematocrit [Volume Fraction] of Blood' for http://loinc.org#20570-8. Valid display is one of 3 choices: 'Hematocrit [Volume Fraction] of Blood by calculation' (en-US), 'Hematocrit [Volume Fraction] of Blood by calculation' (en-US) or 'Hct VFr Bld Calc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[36] (l1​/c22780)informationWrong Display Name 'Hematocrit [Pure volume fraction] of Capillary blood' for http://loinc.org#71831-2. Valid display is one of 3 choices: 'Hematocrit [Pure volume fraction] of Capillary blood by calculation' (en-US), 'Hematocrit [Pure volume fraction] of Capillary blood by calculation' (en-US) or 'Hct VFr.DF BldC Calc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[37] (l1​/c22861)informationWrong Display Name 'Hematocrit [Pure volume fraction] of Venous blood' for http://loinc.org#71829-6. Valid display is one of 3 choices: 'Hematocrit [Pure volume fraction] of Venous blood by calculation' (en-US), 'Hematocrit [Pure volume fraction] of Venous blood by calculation' (en-US) or 'Hct VFr.DF BldV Calc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[42] (l1​/c23277)informationWrong Display Name 'Hematocrit [Volume Fraction] of Capillary blood' for http://loinc.org#42908-4. Valid display is one of 3 choices: 'Hematocrit [Volume Fraction] of Capillary blood by calculation' (en-US), 'Hematocrit [Volume Fraction] of Capillary blood by calculation' (en-US) or 'Hct VFr BldC Calc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[43] (l1​/c23353)informationWrong Display Name 'Hematocrit [Volume Fraction] of Venous blood' for http://loinc.org#41654-5. Valid display is one of 3 choices: 'Hematocrit [Volume Fraction] of Venous blood by calculation' (en-US), 'Hematocrit [Volume Fraction] of Venous blood by calculation' (en-US) or 'Hct VFr BldV Calc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[47] (l1​/c23640)informationWrong Display Name 'Lymphocytes/100 leukocytes in Blood' for http://loinc.org#26478-8. Valid display is one of 3 choices: 'Lymphocytes/Leukocytes in Blood' (en-US), 'Lymphocytes/Leukocytes in Blood' (en-US) or 'Lymphocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[48] (l1​/c23724)informationWrong Display Name 'Lymphocytes/100 leukocytes in Blood by Automated count' for http://loinc.org#736-9. Valid display is one of 3 choices: 'Lymphocytes/Leukocytes in Blood by Automated count' (en-US), 'Lymphocytes/Leukocytes in Blood by Automated count' (en-US) or 'Lymphocytes NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[49] (l1​/c23805)informationWrong Display Name 'Lymphocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#737-7. Valid display is one of 3 choices: 'Lymphocytes/Leukocytes in Blood by Manual count' (en-US), 'Lymphocytes/Leukocytes in Blood by Manual count' (en-US) or 'Lymphocytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[52] (l1​/c24021)informationWrong Display Name 'Metamyelocytes/100 leukocytes in Blood' for http://loinc.org#28541-1. Valid display is one of 3 choices: 'Metamyelocytes/Leukocytes in Blood' (en-US), 'Metamyelocytes/Leukocytes in Blood' (en-US) or 'Metamyelocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[53] (l1​/c24105)informationWrong Display Name 'Metamyelocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#740-1. Valid display is one of 3 choices: 'Metamyelocytes/Leukocytes in Blood by Manual count' (en-US), 'Metamyelocytes/Leukocytes in Blood by Manual count' (en-US) or 'Metamyelocytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[59] (l1​/c24555)informationWrong Display Name 'Monocytes/100 leukocytes in Blood' for http://loinc.org#26485-3. Valid display is one of 3 choices: 'Monocytes/Leukocytes in Blood' (en-US), 'Monocytes/Leukocytes in Blood' (en-US) or 'Monocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[60] (l1​/c24638)informationWrong Display Name 'Monocytes/100 leukocytes in Blood by Automated count' for http://loinc.org#5905-5. Valid display is one of 3 choices: 'Monocytes/Leukocytes in Blood by Automated count' (en-US), 'Monocytes/Leukocytes in Blood by Automated count' (en-US) or 'Monocytes NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[61] (l1​/c24717)informationWrong Display Name 'Monocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#744-3. Valid display is one of 3 choices: 'Monocytes/Leukocytes in Blood by Manual count' (en-US), 'Monocytes/Leukocytes in Blood by Manual count' (en-US) or 'Monocytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[64] (l1​/c24924)informationWrong Display Name 'Myeloblasts/100 leukocytes in Blood' for http://loinc.org#30445-1. Valid display is one of 3 choices: 'Myeloblasts/Leukocytes in Blood' (en-US), 'Myeloblasts/Leukocytes in Blood' (en-US) or 'Myeloblasts NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[65] (l1​/c25005)informationWrong Display Name 'Myeloblasts/100 leukocytes in Blood by Manual count' for http://loinc.org#747-6. Valid display is one of 3 choices: 'Myeloblasts/Leukocytes in Blood by Manual count' (en-US), 'Myeloblasts/Leukocytes in Blood by Manual count' (en-US) or 'Myeloblasts NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[68] (l1​/c25209)informationWrong Display Name 'Myelocytes/100 leukocytes in Blood' for http://loinc.org#26498-6. Valid display is one of 3 choices: 'Myelocytes/Leukocytes in Blood' (en-US), 'Myelocytes/Leukocytes in Blood' (en-US) or 'Myelocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[69] (l1​/c25289)informationWrong Display Name 'Myelocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#749-2. Valid display is one of 3 choices: 'Myelocytes/Leukocytes in Blood by Manual count' (en-US), 'Myelocytes/Leukocytes in Blood by Manual count' (en-US) or 'Myelocytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[74] (l1​/c25677)informationWrong Display Name 'Neutrophils/100 leukocytes in Blood' for http://loinc.org#26511-6. Valid display is one of 3 choices: 'Neutrophils/Leukocytes in Blood' (en-US), 'Neutrophils/Leukocytes in Blood' (en-US) or 'Neutrophils NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[75] (l1​/c25761)informationWrong Display Name 'Neutrophils/100 leukocytes in Blood by Automated count' for http://loinc.org#770-8. Valid display is one of 3 choices: 'Neutrophils/Leukocytes in Blood by Automated count' (en-US), 'Neutrophils/Leukocytes in Blood by Automated count' (en-US) or 'Neutrophils NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[76] (l1​/c25844)informationWrong Display Name 'Neutrophils/100 leukocytes in Blood by Manual count' for http://loinc.org#23761-0. Valid display is one of 3 choices: 'Neutrophils/Leukocytes in Blood by Manual count' (en-US), 'Neutrophils/Leukocytes in Blood by Manual count' (en-US) or 'Neutrophils NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[79] (l1​/c26056)informationWrong Display Name 'Plasma cells/100 leukocytes in Blood' for http://loinc.org#13047-6. Valid display is one of 3 choices: 'Plasma cells/Leukocytes in Blood' (en-US), 'Plasma cells/Leukocytes in Blood' (en-US) or 'Plasma Cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[80] (l1​/c26140)informationWrong Display Name 'Plasma cells/100 leukocytes in Blood by Manual count' for http://loinc.org#79426-3. Valid display is one of 3 choices: 'Plasma cells/Leukocytes in Blood by Manual count' (en-US), 'Plasma cells/Leukocytes in Blood by Manual count' (en-US) or 'Plasma Cells NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[81] (l1​/c26218)informationWrong Display Name 'Platelet mean volume [Entitic volume] in Blood' for http://loinc.org#28542-9. Valid display is one of 3 choices: 'Platelet [Entitic mean volume] in Blood' (en-US), 'Platelet [Entitic mean volume] in Blood' (en-US) or 'PMV Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[82] (l1​/c26315)informationWrong Display Name 'Platelet mean volume [Entitic volume] in Blood by Automated count' for http://loinc.org#32623-1. Valid display is one of 3 choices: 'Platelet [Entitic mean volume] in Blood by Automated count' (en-US), 'Platelet [Entitic mean volume] in Blood by Automated count' (en-US) or 'PMV Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[87] (l1​/c26672)informationWrong Display Name 'Prolymphocytes/100 leukocytes in Blood' for http://loinc.org#30465-9. Valid display is one of 3 choices: 'Prolymphocytes/Leukocytes in Blood' (en-US), 'Prolymphocytes/Leukocytes in Blood' (en-US) or 'Prolymphocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[88] (l1​/c26757)informationWrong Display Name 'Prolymphocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#6746-2. Valid display is one of 3 choices: 'Prolymphocytes/Leukocytes in Blood by Manual count' (en-US), 'Prolymphocytes/Leukocytes in Blood by Manual count' (en-US) or 'Prolymphocytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[91] (l1​/c26969)informationWrong Display Name 'Promonocytes/100 leukocytes in Blood' for http://loinc.org#30466-7. Valid display is one of 3 choices: 'Promonocytes/Leukocytes in Blood' (en-US), 'Promonocytes/Leukocytes in Blood' (en-US) or 'Promonycytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[92] (l1​/c27053)informationWrong Display Name 'Promonocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#13599-6. Valid display is one of 3 choices: 'Promonocytes/Leukocytes in Blood by Manual count' (en-US), 'Promonocytes/Leukocytes in Blood by Manual count' (en-US) or 'Promonycytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[95] (l1​/c27266)informationWrong Display Name 'Promyelocytes/100 leukocytes in Blood' for http://loinc.org#26524-9. Valid display is one of 3 choices: 'Promyelocytes/Leukocytes in Blood' (en-US), 'Promyelocytes/Leukocytes in Blood' (en-US) or 'Promyelocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[96] (l1​/c27349)informationWrong Display Name 'Promyelocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#783-1. Valid display is one of 3 choices: 'Promyelocytes/Leukocytes in Blood by Manual count' (en-US), 'Promyelocytes/Leukocytes in Blood by Manual count' (en-US) or 'Promyelocytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[110] (l1​/c28433)informationWrong Display Name 'Albumin [Moles/volume] in Urine by Detection limit <= 3.0 mg/L' for http://loinc.org#77158-4. Valid display is one of 3 choices: 'Microalbumin [Moles/volume] in Urine by Detection limit <= 3.0 mg/L' (en-US), 'Microalbumin [Moles/volume] in Urine by Detection limit <= 3.0 mg/L' (en-US) or 'Microalbumin Ur DL<=3.0 mg/L-sCnc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[117] (l1​/c29090)warningThe concept '35194-0' has a status of DISCOURAGED and its use should be reviewed (from https://tx.fhir.org/r4, see log) INACTIVE_CONCEPT_FOUND
ValueSet​.compose​.include[0]​.concept[121] (l1​/c29437)warningThe concept '2532-0' has a status of DISCOURAGED and its use should be reviewed (from https://tx.fhir.org/r4, see log) INACTIVE_CONCEPT_FOUND
ValueSet​.compose​.include[0]​.concept[124] (l1​/c29779)warningThe concept '35214-6' has a status of DISCOURAGED and its use should be reviewed (from https://tx.fhir.org/r4, see log) INACTIVE_CONCEPT_FOUND
ValueSet​.compose​.include[0]​.concept[127] (l1​/c30012)warningThe concept '35215-3' has a status of DISCOURAGED and its use should be reviewed (from https://tx.fhir.org/r4, see log) INACTIVE_CONCEPT_FOUND
ValueSet​.compose​.include[0]​.concept[130] (l1​/c30266)warningThe concept '35209-6' has a status of DISCOURAGED and its use should be reviewed (from https://tx.fhir.org/r4, see log) INACTIVE_CONCEPT_FOUND
ValueSet​.compose​.include[0]​.concept[134] (l1​/c30552)informationWrong Display Name 'Blasts/100 cells in Bone marrow' for http://loinc.org#11150-0. Valid display is one of 3 choices: 'Blasts/cells in Bone marrow' (en-US), 'Blasts/cells in Bone marrow' (en-US) or 'Blasts NFr Mar' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[136] (l1​/c30686)informationWrong Display Name 'Segmented neutrophils/100 leukocytes in Blood' for http://loinc.org#26505-8. Valid display is one of 3 choices: 'Segmented neutrophils/Leukocytes in Blood' (en-US), 'Segmented neutrophils/Leukocytes in Blood' (en-US) or 'Neuts Seg NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[137] (l1​/c30782)informationWrong Display Name 'Segmented neutrophils/100 leukocytes in Blood by Automated count' for http://loinc.org#32200-8. Valid display is one of 3 choices: 'Segmented neutrophils/Leukocytes in Blood by Automated count' (en-US), 'Segmented neutrophils/Leukocytes in Blood by Automated count' (en-US) or 'Neuts Seg NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[138] (l1​/c30873)informationWrong Display Name 'Segmented neutrophils/100 leukocytes in Blood by Manual count' for http://loinc.org#769-0. Valid display is one of 3 choices: 'Segmented neutrophils/Leukocytes in Blood by Manual count' (en-US), 'Segmented neutrophils/Leukocytes in Blood by Manual count' (en-US) or 'Neuts Seg NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[139] (l1​/c30943)informationWrong Display Name 'Reticulocytes/100 erythrocytes in Blood' for http://loinc.org#4679-7. Valid display is one of 3 choices: 'Reticulocytes/Erythrocytes in Blood' (en-US), 'Reticulocytes/Erythrocytes in Blood' (en-US) or 'Retics/RBC NFr' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[140] (l1​/c31033)informationWrong Display Name 'Reticulocytes/100 erythrocytes in Blood by Automated count' for http://loinc.org#17849-1. Valid display is one of 3 choices: 'Reticulocytes/Erythrocytes in Blood by Automated count' (en-US), 'Reticulocytes/Erythrocytes in Blood by Automated count' (en-US) or 'Retics/RBC NFr Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[141] (l1​/c31114)informationWrong Display Name 'Reticulocytes/100 erythrocytes in Blood by Manual' for http://loinc.org#31112-6. Valid display is one of 3 choices: 'Reticulocytes/Erythrocytes in Blood by Manual' (en-US), 'Reticulocytes/Erythrocytes in Blood by Manual' (en-US) or 'Retics/RBC NFr Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT

fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.json Show Validation Information (1)

PathSeverityMessage
ValueSet​.compose​.include[0]​.concept[1] (l1​/c10027)informationWrong Display Name 'Basophils/100 leukocytes in Blood' for http://loinc.org#30180-4. Valid display is one of 3 choices: 'Basophils/Leukocytes in Blood' (en-US), 'Basophils/Leukocytes in Blood' (en-US) or 'Basophils NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[3] (l1​/c10162)informationWrong Display Name 'Immature basophils/100 leukocytes in Blood' for http://loinc.org#34911-8. Valid display is one of 3 choices: 'Immature basophils/Leukocytes in Blood' (en-US), 'Immature basophils/Leukocytes in Blood' (en-US) or 'Imm Basophils NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[5] (l1​/c10294)informationWrong Display Name 'Blasts/100 leukocytes in Blood' for http://loinc.org#26446-5. Valid display is one of 3 choices: 'Blasts/Leukocytes in Blood' (en-US), 'Blasts/Leukocytes in Blood' (en-US) or 'Blasts NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[7] (l1​/c10419)informationWrong Display Name 'Eosinophils/100 leukocytes in Blood' for http://loinc.org#26450-7. Valid display is one of 3 choices: 'Eosinophils/Leukocytes in Blood' (en-US), 'Eosinophils/Leukocytes in Blood' (en-US) or 'Eosinophil NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[9] (l1​/c10558)informationWrong Display Name 'Immature eosinophils/100 leukocytes in Blood' for http://loinc.org#34913-4. Valid display is one of 3 choices: 'Immature eosinophils/Leukocytes in Blood' (en-US), 'Immature eosinophils/Leukocytes in Blood' (en-US) or 'Imm Eosinophil NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[11] (l1​/c10698)informationWrong Display Name 'Granulocytes/100 leukocytes in Blood' for http://loinc.org#30395-8. Valid display is one of 3 choices: 'Granulocytes/Leukocytes in Blood' (en-US), 'Granulocytes/Leukocytes in Blood' (en-US) or 'Granulocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[13] (l1​/c10829)informationWrong Display Name 'Hairy cells/100 leukocytes in Blood' for http://loinc.org#35058-7. Valid display is one of 3 choices: 'Hairy cells/Leukocytes in Blood' (en-US), 'Hairy cells/Leukocytes in Blood' (en-US) or 'Hairy Cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[15] (l1​/c10969)informationWrong Display Name 'Large unstained cells/100 leukocytes in Blood' for http://loinc.org#26463-0. Valid display is one of 3 choices: 'Large unstained cells/Leukocytes in Blood' (en-US), 'Large unstained cells/Leukocytes in Blood' (en-US) or 'LUC NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[17] (l1​/c11114)informationWrong Display Name 'Leukocytes other/100 leukocytes in Blood' for http://loinc.org#26471-3. Valid display is one of 3 choices: 'Leukocytes other/Leukocytes in Blood' (en-US), 'Leukocytes other/Leukocytes in Blood' (en-US) or 'WBC Other NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[19] (l1​/c11250)informationWrong Display Name 'Lymphoblasts/100 leukocytes in Blood' for http://loinc.org#34922-5. Valid display is one of 3 choices: 'Lymphoblasts/Leukocytes in Blood' (en-US), 'Lymphoblasts/Leukocytes in Blood' (en-US) or 'Lymphoblasts NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[21] (l1​/c11381)informationWrong Display Name 'Lymphocytes/100 leukocytes in Blood' for http://loinc.org#26478-8. Valid display is one of 3 choices: 'Lymphocytes/Leukocytes in Blood' (en-US), 'Lymphocytes/Leukocytes in Blood' (en-US) or 'Lymphocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[23] (l1​/c11520)informationWrong Display Name 'Abnormal lymphocytes/100 leukocytes in Blood' for http://loinc.org#30413-9. Valid display is one of 3 choices: 'Abnormal lymphocytes/Leukocytes in Blood' (en-US), 'Abnormal lymphocytes/Leukocytes in Blood' (en-US) or 'Lymph Abn NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[25] (l1​/c11667)informationWrong Display Name 'Variant lymphocytes/100 leukocytes in Blood' for http://loinc.org#13046-8. Valid display is one of 3 choices: 'Variant lymphocytes/Leukocytes in Blood' (en-US), 'Variant lymphocytes/Leukocytes in Blood' (en-US) or 'Variant Lymphs NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[27] (l1​/c11820)informationWrong Display Name 'Large granular lymphocytes/100 leukocytes in Blood' for http://loinc.org#30420-4. Valid display is one of 3 choices: 'Large granular lymphocytes/Leukocytes in Blood' (en-US), 'Large granular lymphocytes/Leukocytes in Blood' (en-US) or 'Lg Gran Lymphs NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[29] (l1​/c11978)informationWrong Display Name 'Lymphocytes Plasmacytoid/100 leukocytes in Blood' for http://loinc.org#34921-7. Valid display is one of 3 choices: 'Lymphocytes Plasmacytoid/Leukocytes in Blood' (en-US), 'Lymphocytes Plasmacytoid/Leukocytes in Blood' (en-US) or 'Plasmacoid Lymphs NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[31] (l1​/c12124)informationWrong Display Name 'Lymphoma cells/100 leukocytes in Blood' for http://loinc.org#30423-8. Valid display is one of 3 choices: 'Lymphoma cells/Leukocytes in Blood' (en-US), 'Lymphoma cells/Leukocytes in Blood' (en-US) or 'Lymphoma Cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[33] (l1​/c12261)informationWrong Display Name 'Malignant cells/100 leukocytes in Blood' for http://loinc.org#34915-9. Valid display is one of 3 choices: 'Malignant cells/Leukocytes in Blood' (en-US), 'Malignant cells/Leukocytes in Blood' (en-US) or 'Malignant cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[35] (l1​/c12398)informationWrong Display Name 'Metamyelocytes/100 leukocytes in Blood' for http://loinc.org#28541-1. Valid display is one of 3 choices: 'Metamyelocytes/Leukocytes in Blood' (en-US), 'Metamyelocytes/Leukocytes in Blood' (en-US) or 'Metamyelocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[37] (l1​/c12530)informationWrong Display Name 'Monoblasts/100 leukocytes in Blood' for http://loinc.org#34923-3. Valid display is one of 3 choices: 'Monoblasts/Leukocytes in Blood' (en-US), 'Monoblasts/Leukocytes in Blood' (en-US) or 'Monoblasts NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[39] (l1​/c12657)informationWrong Display Name 'Monocytes/100 leukocytes in Blood' for http://loinc.org#26485-3. Valid display is one of 3 choices: 'Monocytes/Leukocytes in Blood' (en-US), 'Monocytes/Leukocytes in Blood' (en-US) or 'Monocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[41] (l1​/c12792)informationWrong Display Name 'Monocytes Abnormal/100 leukocytes in Blood' for http://loinc.org#30441-0. Valid display is one of 3 choices: 'Monocytes Abnormal/Leukocytes in Blood' (en-US), 'Monocytes Abnormal/Leukocytes in Blood' (en-US) or 'Abn Monocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[43] (l1​/c12936)informationWrong Display Name 'Immature monocytes/100 leukocytes in Blood' for http://loinc.org#34925-8. Valid display is one of 3 choices: 'Immature monocytes/Leukocytes in Blood' (en-US), 'Immature monocytes/Leukocytes in Blood' (en-US) or 'Imm Moncytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[45] (l1​/c13073)informationWrong Display Name 'Myeloblasts/100 leukocytes in Blood' for http://loinc.org#30445-1. Valid display is one of 3 choices: 'Myeloblasts/Leukocytes in Blood' (en-US), 'Myeloblasts/Leukocytes in Blood' (en-US) or 'Myeloblasts NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[47] (l1​/c13202)informationWrong Display Name 'Myelocytes/100 leukocytes in Blood' for http://loinc.org#26498-6. Valid display is one of 3 choices: 'Myelocytes/Leukocytes in Blood' (en-US), 'Myelocytes/Leukocytes in Blood' (en-US) or 'Myelocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[49] (l1​/c13331)informationWrong Display Name 'Neutrophils/100 leukocytes in Blood' for http://loinc.org#26511-6. Valid display is one of 3 choices: 'Neutrophils/Leukocytes in Blood' (en-US), 'Neutrophils/Leukocytes in Blood' (en-US) or 'Neutrophils NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[51] (l1​/c13471)informationWrong Display Name 'Band form neutrophils/100 leukocytes in Blood' for http://loinc.org#26508-2. Valid display is one of 3 choices: 'Band form neutrophils/Leukocytes in Blood' (en-US), 'Band form neutrophils/Leukocytes in Blood' (en-US) or 'Neuts Band NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[53] (l1​/c13626)informationWrong Display Name 'Neutrophils.hypersegmented/100 leukocytes in Blood' for http://loinc.org#30450-1. Valid display is one of 3 choices: 'Neutrophils.hypersegmented/Leukocytes in Blood' (en-US), 'Neutrophils.hypersegmented/Leukocytes in Blood' (en-US) or 'Neuts Hyperseg NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[56] (l1​/c13854)informationWrong Display Name 'Segmented neutrophils/100 leukocytes in Blood' for http://loinc.org#26505-8. Valid display is one of 3 choices: 'Segmented neutrophils/Leukocytes in Blood' (en-US), 'Segmented neutrophils/Leukocytes in Blood' (en-US) or 'Neuts Seg NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[57] (l1​/c13931)informationWrong Display Name 'Plasma cell precursor/100 leukocytes in Blood' for http://loinc.org#34917-5. Valid display is one of 3 choices: 'Plasma cell precursor/Leukocytes in Blood' (en-US), 'Plasma cell precursor/Leukocytes in Blood' (en-US) or 'Plasma cell prec NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[59] (l1​/c14072)informationWrong Display Name 'Plasma cells/100 leukocytes in Blood' for http://loinc.org#13047-6. Valid display is one of 3 choices: 'Plasma cells/Leukocytes in Blood' (en-US), 'Plasma cells/Leukocytes in Blood' (en-US) or 'Plasma Cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[61] (l1​/c14215)informationWrong Display Name 'Polymorphonuclear cells/100 leukocytes in Blood' for http://loinc.org#34999-3. Valid display is one of 3 choices: 'Deprecated Polymorphonuclear cells/100 leukocytes in Blood' (en-US), 'Deprecated Polymorphonuclear cells/100 leukocytes in Blood' (en-US) or 'Deprecated Polys/leuk NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[61] (l1​/c14215)warningThe concept '34999-3' is deprecated and its use should be reviewed (from https://tx.fhir.org/r4, see log) DEPRECATED_CONCEPT_FOUND
ValueSet​.compose​.include[0]​.concept[62] (l1​/c14290)informationWrong Display Name 'Polymorphonuclear cells [#/volume] in Blood' for http://loinc.org#35003-3. Valid display is one of 3 choices: 'Deprecated Polymorphonuclear cells [#/volume] in Blood' (en-US), 'Deprecated Polymorphonuclear cells [#/volume] in Blood' (en-US) or 'Deprecated Polys # Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[62] (l1​/c14290)warningThe concept '35003-3' is deprecated and its use should be reviewed (from https://tx.fhir.org/r4, see log) DEPRECATED_CONCEPT_FOUND
ValueSet​.compose​.include[0]​.concept[63] (l1​/c14360)informationWrong Display Name 'Prolymphocytes/100 leukocytes in Blood' for http://loinc.org#30465-9. Valid display is one of 3 choices: 'Prolymphocytes/Leukocytes in Blood' (en-US), 'Prolymphocytes/Leukocytes in Blood' (en-US) or 'Prolymphocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[65] (l1​/c14494)informationWrong Display Name 'Promonocytes/100 leukocytes in Blood' for http://loinc.org#30466-7. Valid display is one of 3 choices: 'Promonocytes/Leukocytes in Blood' (en-US), 'Promonocytes/Leukocytes in Blood' (en-US) or 'Promonycytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[67] (l1​/c14627)informationWrong Display Name 'Promyelocytes/100 leukocytes in Blood' for http://loinc.org#26524-9. Valid display is one of 3 choices: 'Promyelocytes/Leukocytes in Blood' (en-US), 'Promyelocytes/Leukocytes in Blood' (en-US) or 'Promyelocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[69] (l1​/c14760)informationWrong Display Name 'Sezary cells/100 leukocytes in Blood' for http://loinc.org#34919-1. Valid display is one of 3 choices: 'Sezary cells/Leukocytes in Blood' (en-US), 'Sezary cells/Leukocytes in Blood' (en-US) or 'Sezary Cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[0]​.concept[71] (l1​/c14892)informationWrong Display Name 'Smudge cells/100 leukocytes in Blood' for http://loinc.org#34992-8. Valid display is one of 3 choices: 'Smudge cells/Leukocytes in Blood' (en-US), 'Smudge cells/Leukocytes in Blood' (en-US) or 'Smudge Cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT

fsh-generated\resources\ValueSet-manual-differential-blood-vs.json Show Validation Information (1)

PathSeverityMessage
ValueSet​.compose​.include[1]​.concept[1] (l1​/c10418)informationWrong Display Name 'Basophils/100 leukocytes in Blood' for http://loinc.org#30180-4. Valid display is one of 3 choices: 'Basophils/Leukocytes in Blood' (en-US), 'Basophils/Leukocytes in Blood' (en-US) or 'Basophils NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[3] (l1​/c10553)informationWrong Display Name 'Immature basophils/100 leukocytes in Blood' for http://loinc.org#34911-8. Valid display is one of 3 choices: 'Immature basophils/Leukocytes in Blood' (en-US), 'Immature basophils/Leukocytes in Blood' (en-US) or 'Imm Basophils NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[5] (l1​/c10685)informationWrong Display Name 'Blasts/100 leukocytes in Blood' for http://loinc.org#26446-5. Valid display is one of 3 choices: 'Blasts/Leukocytes in Blood' (en-US), 'Blasts/Leukocytes in Blood' (en-US) or 'Blasts NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[7] (l1​/c10810)informationWrong Display Name 'Eosinophils/100 leukocytes in Blood' for http://loinc.org#26450-7. Valid display is one of 3 choices: 'Eosinophils/Leukocytes in Blood' (en-US), 'Eosinophils/Leukocytes in Blood' (en-US) or 'Eosinophil NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[9] (l1​/c10949)informationWrong Display Name 'Immature eosinophils/100 leukocytes in Blood' for http://loinc.org#34913-4. Valid display is one of 3 choices: 'Immature eosinophils/Leukocytes in Blood' (en-US), 'Immature eosinophils/Leukocytes in Blood' (en-US) or 'Imm Eosinophil NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[11] (l1​/c11089)informationWrong Display Name 'Granulocytes/100 leukocytes in Blood' for http://loinc.org#30395-8. Valid display is one of 3 choices: 'Granulocytes/Leukocytes in Blood' (en-US), 'Granulocytes/Leukocytes in Blood' (en-US) or 'Granulocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[13] (l1​/c11220)informationWrong Display Name 'Hairy cells/100 leukocytes in Blood' for http://loinc.org#35058-7. Valid display is one of 3 choices: 'Hairy cells/Leukocytes in Blood' (en-US), 'Hairy cells/Leukocytes in Blood' (en-US) or 'Hairy Cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[15] (l1​/c11360)informationWrong Display Name 'Large unstained cells/100 leukocytes in Blood' for http://loinc.org#26463-0. Valid display is one of 3 choices: 'Large unstained cells/Leukocytes in Blood' (en-US), 'Large unstained cells/Leukocytes in Blood' (en-US) or 'LUC NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[17] (l1​/c11505)informationWrong Display Name 'Leukocytes other/100 leukocytes in Blood' for http://loinc.org#26471-3. Valid display is one of 3 choices: 'Leukocytes other/Leukocytes in Blood' (en-US), 'Leukocytes other/Leukocytes in Blood' (en-US) or 'WBC Other NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[19] (l1​/c11641)informationWrong Display Name 'Lymphoblasts/100 leukocytes in Blood' for http://loinc.org#34922-5. Valid display is one of 3 choices: 'Lymphoblasts/Leukocytes in Blood' (en-US), 'Lymphoblasts/Leukocytes in Blood' (en-US) or 'Lymphoblasts NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[21] (l1​/c11772)informationWrong Display Name 'Lymphocytes/100 leukocytes in Blood' for http://loinc.org#26478-8. Valid display is one of 3 choices: 'Lymphocytes/Leukocytes in Blood' (en-US), 'Lymphocytes/Leukocytes in Blood' (en-US) or 'Lymphocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[23] (l1​/c11911)informationWrong Display Name 'Abnormal lymphocytes/100 leukocytes in Blood' for http://loinc.org#30413-9. Valid display is one of 3 choices: 'Abnormal lymphocytes/Leukocytes in Blood' (en-US), 'Abnormal lymphocytes/Leukocytes in Blood' (en-US) or 'Lymph Abn NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[25] (l1​/c12058)informationWrong Display Name 'Variant lymphocytes/100 leukocytes in Blood' for http://loinc.org#13046-8. Valid display is one of 3 choices: 'Variant lymphocytes/Leukocytes in Blood' (en-US), 'Variant lymphocytes/Leukocytes in Blood' (en-US) or 'Variant Lymphs NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[27] (l1​/c12211)informationWrong Display Name 'Large granular lymphocytes/100 leukocytes in Blood' for http://loinc.org#30420-4. Valid display is one of 3 choices: 'Large granular lymphocytes/Leukocytes in Blood' (en-US), 'Large granular lymphocytes/Leukocytes in Blood' (en-US) or 'Lg Gran Lymphs NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[29] (l1​/c12369)informationWrong Display Name 'Lymphocytes Plasmacytoid/100 leukocytes in Blood' for http://loinc.org#34921-7. Valid display is one of 3 choices: 'Lymphocytes Plasmacytoid/Leukocytes in Blood' (en-US), 'Lymphocytes Plasmacytoid/Leukocytes in Blood' (en-US) or 'Plasmacoid Lymphs NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[31] (l1​/c12515)informationWrong Display Name 'Lymphoma cells/100 leukocytes in Blood' for http://loinc.org#30423-8. Valid display is one of 3 choices: 'Lymphoma cells/Leukocytes in Blood' (en-US), 'Lymphoma cells/Leukocytes in Blood' (en-US) or 'Lymphoma Cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[33] (l1​/c12652)informationWrong Display Name 'Malignant cells/100 leukocytes in Blood' for http://loinc.org#34915-9. Valid display is one of 3 choices: 'Malignant cells/Leukocytes in Blood' (en-US), 'Malignant cells/Leukocytes in Blood' (en-US) or 'Malignant cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[35] (l1​/c12789)informationWrong Display Name 'Metamyelocytes/100 leukocytes in Blood' for http://loinc.org#28541-1. Valid display is one of 3 choices: 'Metamyelocytes/Leukocytes in Blood' (en-US), 'Metamyelocytes/Leukocytes in Blood' (en-US) or 'Metamyelocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[37] (l1​/c12921)informationWrong Display Name 'Monoblasts/100 leukocytes in Blood' for http://loinc.org#34923-3. Valid display is one of 3 choices: 'Monoblasts/Leukocytes in Blood' (en-US), 'Monoblasts/Leukocytes in Blood' (en-US) or 'Monoblasts NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[39] (l1​/c13048)informationWrong Display Name 'Monocytes/100 leukocytes in Blood' for http://loinc.org#26485-3. Valid display is one of 3 choices: 'Monocytes/Leukocytes in Blood' (en-US), 'Monocytes/Leukocytes in Blood' (en-US) or 'Monocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[41] (l1​/c13183)informationWrong Display Name 'Monocytes Abnormal/100 leukocytes in Blood' for http://loinc.org#30441-0. Valid display is one of 3 choices: 'Monocytes Abnormal/Leukocytes in Blood' (en-US), 'Monocytes Abnormal/Leukocytes in Blood' (en-US) or 'Abn Monocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[43] (l1​/c13327)informationWrong Display Name 'Immature monocytes/100 leukocytes in Blood' for http://loinc.org#34925-8. Valid display is one of 3 choices: 'Immature monocytes/Leukocytes in Blood' (en-US), 'Immature monocytes/Leukocytes in Blood' (en-US) or 'Imm Moncytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[45] (l1​/c13464)informationWrong Display Name 'Myeloblasts/100 leukocytes in Blood' for http://loinc.org#30445-1. Valid display is one of 3 choices: 'Myeloblasts/Leukocytes in Blood' (en-US), 'Myeloblasts/Leukocytes in Blood' (en-US) or 'Myeloblasts NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[47] (l1​/c13593)informationWrong Display Name 'Myelocytes/100 leukocytes in Blood' for http://loinc.org#26498-6. Valid display is one of 3 choices: 'Myelocytes/Leukocytes in Blood' (en-US), 'Myelocytes/Leukocytes in Blood' (en-US) or 'Myelocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[49] (l1​/c13722)informationWrong Display Name 'Neutrophils/100 leukocytes in Blood' for http://loinc.org#26511-6. Valid display is one of 3 choices: 'Neutrophils/Leukocytes in Blood' (en-US), 'Neutrophils/Leukocytes in Blood' (en-US) or 'Neutrophils NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[51] (l1​/c13862)informationWrong Display Name 'Band form neutrophils/100 leukocytes in Blood' for http://loinc.org#26508-2. Valid display is one of 3 choices: 'Band form neutrophils/Leukocytes in Blood' (en-US), 'Band form neutrophils/Leukocytes in Blood' (en-US) or 'Neuts Band NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[53] (l1​/c14017)informationWrong Display Name 'Neutrophils.hypersegmented/100 leukocytes in Blood' for http://loinc.org#30450-1. Valid display is one of 3 choices: 'Neutrophils.hypersegmented/Leukocytes in Blood' (en-US), 'Neutrophils.hypersegmented/Leukocytes in Blood' (en-US) or 'Neuts Hyperseg NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[56] (l1​/c14245)informationWrong Display Name 'Segmented neutrophils/100 leukocytes in Blood' for http://loinc.org#26505-8. Valid display is one of 3 choices: 'Segmented neutrophils/Leukocytes in Blood' (en-US), 'Segmented neutrophils/Leukocytes in Blood' (en-US) or 'Neuts Seg NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[57] (l1​/c14322)informationWrong Display Name 'Plasma cell precursor/100 leukocytes in Blood' for http://loinc.org#34917-5. Valid display is one of 3 choices: 'Plasma cell precursor/Leukocytes in Blood' (en-US), 'Plasma cell precursor/Leukocytes in Blood' (en-US) or 'Plasma cell prec NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[59] (l1​/c14463)informationWrong Display Name 'Plasma cells/100 leukocytes in Blood' for http://loinc.org#13047-6. Valid display is one of 3 choices: 'Plasma cells/Leukocytes in Blood' (en-US), 'Plasma cells/Leukocytes in Blood' (en-US) or 'Plasma Cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[61] (l1​/c14606)informationWrong Display Name 'Polymorphonuclear cells/100 leukocytes in Blood' for http://loinc.org#34999-3. Valid display is one of 3 choices: 'Deprecated Polymorphonuclear cells/100 leukocytes in Blood' (en-US), 'Deprecated Polymorphonuclear cells/100 leukocytes in Blood' (en-US) or 'Deprecated Polys/leuk NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[61] (l1​/c14606)warningThe concept '34999-3' is deprecated and its use should be reviewed (from https://tx.fhir.org/r4, see log) DEPRECATED_CONCEPT_FOUND
ValueSet​.compose​.include[1]​.concept[62] (l1​/c14681)informationWrong Display Name 'Polymorphonuclear cells [#/volume] in Blood' for http://loinc.org#35003-3. Valid display is one of 3 choices: 'Deprecated Polymorphonuclear cells [#/volume] in Blood' (en-US), 'Deprecated Polymorphonuclear cells [#/volume] in Blood' (en-US) or 'Deprecated Polys # Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[62] (l1​/c14681)warningThe concept '35003-3' is deprecated and its use should be reviewed (from https://tx.fhir.org/r4, see log) DEPRECATED_CONCEPT_FOUND
ValueSet​.compose​.include[1]​.concept[63] (l1​/c14751)informationWrong Display Name 'Prolymphocytes/100 leukocytes in Blood' for http://loinc.org#30465-9. Valid display is one of 3 choices: 'Prolymphocytes/Leukocytes in Blood' (en-US), 'Prolymphocytes/Leukocytes in Blood' (en-US) or 'Prolymphocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[65] (l1​/c14885)informationWrong Display Name 'Promonocytes/100 leukocytes in Blood' for http://loinc.org#30466-7. Valid display is one of 3 choices: 'Promonocytes/Leukocytes in Blood' (en-US), 'Promonocytes/Leukocytes in Blood' (en-US) or 'Promonycytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[67] (l1​/c15018)informationWrong Display Name 'Promyelocytes/100 leukocytes in Blood' for http://loinc.org#26524-9. Valid display is one of 3 choices: 'Promyelocytes/Leukocytes in Blood' (en-US), 'Promyelocytes/Leukocytes in Blood' (en-US) or 'Promyelocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[69] (l1​/c15151)informationWrong Display Name 'Sezary cells/100 leukocytes in Blood' for http://loinc.org#34919-1. Valid display is one of 3 choices: 'Sezary cells/Leukocytes in Blood' (en-US), 'Sezary cells/Leukocytes in Blood' (en-US) or 'Sezary Cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT
ValueSet​.compose​.include[1]​.concept[71] (l1​/c15283)informationWrong Display Name 'Smudge cells/100 leukocytes in Blood' for http://loinc.org#34992-8. Valid display is one of 3 choices: 'Smudge cells/Leukocytes in Blood' (en-US), 'Smudge cells/Leukocytes in Blood' (en-US) or 'Smudge Cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT

Suppressed Messages (Warnings, hints, broken links)

No suppressed messsages

Errors sorted by type


All_observations_should_have_a_performer

fsh-generated\resources\Observation-ABOBloodGroupObservationLOINC.jsonBest Practice Recommendation: In general, all observations should have a performer
fsh-generated\resources\Observation-ABOBloodGroupObservationSNOMED.jsonBest Practice Recommendation: In general, all observations should have a performer
fsh-generated\resources\Observation-ABORhObservationLOINC.jsonBest Practice Recommendation: In general, all observations should have a performer
fsh-generated\resources\Observation-ABORhObservationSNOMED.jsonBest Practice Recommendation: In general, all observations should have a performer
fsh-generated\resources\Observation-AlbuminObservation.jsonBest Practice Recommendation: In general, all observations should have a performer
fsh-generated\resources\Observation-BasophilsObservation.jsonBest Practice Recommendation: In general, all observations should have a performer
fsh-generated\resources\Observation-BodyHeight.jsonBest Practice Recommendation: In general, all observations should have a performer
fsh-generated\resources\Observation-BodyWeight.jsonBest Practice Recommendation: In general, all observations should have a performer
fsh-generated\resources\Observation-CMVDNAViralLoadCopiesmL.jsonBest Practice Recommendation: In general, all observations should have a performer
fsh-generated\resources\Observation-CMVDNAViralLoadIUmL.jsonBest Practice Recommendation: In general, all observations should have a performer
fsh-generated\resources\Observation-CMVIgAbPresenceSNOMED.jsonBest Practice Recommendation: In general, all observations should have a performer
fsh-generated\resources\Observation-CMVIgGAbPresenceLOINC.jsonBest Practice Recommendation: In general, all observations should have a performer
fsh-generated\resources\Observation-CMVIgMAbPresenceLOINC.jsonBest Practice Recommendation: In general, all observations should have a performer
fsh-generated\resources\Observation-CMVIgMAbPresenceSNOMED.jsonBest Practice Recommendation: In general, all observations should have a performer
fsh-generated\resources\Observation-Cytogenetics-Example-1.jsonBest Practice Recommendation: In general, all observations should have a performer
fsh-generated\resources\Observation-EosinophilsObservation.jsonBest Practice Recommendation: In general, all observations should have a performer
fsh-generated\resources\Observation-HemoglobinObservation.jsonBest Practice Recommendation: In general, all observations should have a performer
fsh-generated\resources\Observation-LeukocytesObservation.jsonBest Practice Recommendation: In general, all observations should have a performer
fsh-generated\resources\Observation-MetamyelocytesObservation.jsonBest Practice Recommendation: In general, all observations should have a performer
fsh-generated\resources\Observation-NeutrophilsObservation.jsonBest Practice Recommendation: In general, all observations should have a performer

CODESYSTEM_SHAREABLE_MISSING

fsh-generated\resources\CodeSystem-cibmtr-ancestry-cs.jsonPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.experimental is mandatory, but it is not present
fsh-generated\resources\CodeSystem-cibmtr-ancestry-cs.jsonPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.caseSensitive is mandatory, but it is not present

DEPRECATED_CONCEPT_FOUND

fsh-generated\resources\ValueSet-cbc-w-differential-unspecified-blood-vs.jsonThe concept '30384-2' is deprecated and its use should be reviewed
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonThe concept '34999-3' is deprecated and its use should be reviewed
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonThe concept '35003-3' is deprecated and its use should be reviewed
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonThe concept '34999-3' is deprecated and its use should be reviewed
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonThe concept '35003-3' is deprecated and its use should be reviewed

Details_for__matching_against_Profile_

fsh-generated\resources\Patient-PatientExample1.jsonThis element does not match any known slice defined in the profile http://fhir.nmdp.org/ig/cibmtr-reporting/StructureDefinition/cibmtr-patient|0.1.11 (this may not be a problem, but you should check that it's not intended to match a slice)
fsh-generated\resources\Patient-PatientExample2.jsonThis element does not match any known slice defined in the profile http://fhir.nmdp.org/ig/cibmtr-reporting/StructureDefinition/cibmtr-patient|0.1.11 (this may not be a problem, but you should check that it's not intended to match a slice)
fsh-generated\resources\Patient-PatientExample3.jsonThis element does not match any known slice defined in the profile http://fhir.nmdp.org/ig/cibmtr-reporting/StructureDefinition/cibmtr-patient|0.1.11 (this may not be a problem, but you should check that it's not intended to match a slice)
fsh-generated\resources\Patient-PatientExample4.jsonThis element does not match any known slice defined in the profile http://fhir.nmdp.org/ig/cibmtr-reporting/StructureDefinition/cibmtr-patient|0.1.11 (this may not be a problem, but you should check that it's not intended to match a slice)
fsh-generated\resources\Patient-PatientExample5.jsonThis element does not match any known slice defined in the profile http://fhir.nmdp.org/ig/cibmtr-reporting/StructureDefinition/cibmtr-patient|0.1.11 (this may not be a problem, but you should check that it's not intended to match a slice)

Display_Name_for__should_be_one_of__instead_of

fsh-generated\resources\Observation-BasophilsObservation.jsonWrong Display Name 'Basophils/100 leukocytes in Blood' for http://loinc.org#30180-4. Valid display is one of 3 choices: 'Basophils/Leukocytes in Blood' (en-US), 'Basophils/Leukocytes in Blood' (en-US) or 'Basophils NFr Bld' (en-US) (for the language(s) 'en-US')

IG_DEPENDENCY_VERSION_WARNING_OLD

fsh-generated\resources\ImplementationGuide-nmdp.fhir.cibmtr-reporting.jsonThe ImplementationGuide uses package hl7.fhir.us.core#8.0.0 released on 2025-06-10, but the most recent appropriate version is 9.0.0. This reference is getting old and the more recent version should be considered
fsh-generated\resources\ImplementationGuide-nmdp.fhir.cibmtr-reporting.jsonThe ImplementationGuide uses package hl7.fhir.uv.genomics-reporting#2.0.0 released on 2022-05-09, but the most recent appropriate version is 3.0.0. This reference is getting old and the more recent version should be considered

INACTIVE_CONCEPT_FOUND

fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonThe concept '35194-0' has a status of DISCOURAGED and its use should be reviewed
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonThe concept '2532-0' has a status of DISCOURAGED and its use should be reviewed
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonThe concept '35214-6' has a status of DISCOURAGED and its use should be reviewed
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonThe concept '35215-3' has a status of DISCOURAGED and its use should be reviewed
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonThe concept '35209-6' has a status of DISCOURAGED and its use should be reviewed

MSG_DEPENDS_ON_DEPRECATED_NOTE

fsh-generated\resources\StructureDefinition-cibmtr-additional-peri-transplant-medication.jsonThe extension http://hl7.org/fhir/StructureDefinition/elementdefinition-maxValueSet|5.3.0 is deprecated with the note: 'Use additionalBinding extension or element instead'
fsh-generated\resources\StructureDefinition-cibmtr-cytogenetics.jsonThe extension http://hl7.org/fhir/StructureDefinition/observation-secondaryFinding|5.3.0 is deprecated with the note: 'This extension is deprecated - use the [[[http://hl7.org/fhir/StructureDefinition/observation-structure-type]]] instead'

MSG_RETIRED

fsh-generated\resources\Medication-Medication-Cyclophosphamide-Example.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Medication-Medication-Etoposide-Example.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Medication-Medication-GVHD-Prophylaxis-Example.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Medication-Medication-Mobilizing-Agent-Example.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Medication-Medication-Peri-Transplant-Example.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Medication-Medication-Post-HCT-Disease-Therapy-Example.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Medication-Medication-Prep-Regimen-Example.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Medication-Medication-PriorExposure-Example.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\MedicationAdministration-MedicationAdministration-Example1.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\MedicationAdministration-MedicationAdministration-Example2.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\MedicationRequest-MedicationRequest-Etoposide-Example.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Observation-ABOBloodGroupObservationLOINC.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Observation-ABOBloodGroupObservationSNOMED.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Observation-ABORhObservationLOINC.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Observation-ABORhObservationSNOMED.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Observation-AlbuminObservation.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Observation-BasophilsObservation.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Observation-BodyHeight.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Observation-BodyWeight.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Observation-CMVDNAViralLoadCopiesmL.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Observation-CMVDNAViralLoadIUmL.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Observation-CMVIgAbPresenceSNOMED.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Observation-CMVIgGAbPresenceLOINC.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Observation-CMVIgMAbPresenceLOINC.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Observation-CMVIgMAbPresenceSNOMED.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Observation-Cytogenetics-Example-1.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Observation-EosinophilsObservation.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Observation-HemoglobinObservation.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Observation-LeukocytesObservation.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Observation-MetamyelocytesObservation.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Observation-NeutrophilsObservation.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Patient-PatientExample1.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Patient-PatientExample2.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Patient-PatientExample3.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Patient-PatientExample4.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Patient-PatientExample5.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0
fsh-generated\resources\Patient-PatientExample6.jsonReference to retired ValueSet http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw|3.0.0

RESOURCE_CANONICAL_MISMATCH

fsh-generated\resources\CodeSystem-cibmtr-ancestry-cs.jsonConformance resource D:\IG\0515_Final\build\fsh-generated\resources\CodeSystem-cibmtr-ancestry-cs.json - the canonical URL (http://fhir.nmdp.org/ig/cibmtr-reporting/CodeSystem/cibmtr-ancestry-cs) does not match the URL (http://example.org/fhir/CodeSystem/cibmtr-ancestry). Use the special-url parameter if you really mean for it not to match
fsh-generated\resources\StructureDefinition-cibmtr-ancestry.jsonConformance resource D:\IG\0515_Final\build\fsh-generated\resources\StructureDefinition-cibmtr-ancestry.json - the canonical URL (http://fhir.nmdp.org/ig/cibmtr-reporting/StructureDefinition/cibmtr-ancestry) does not match the URL (http://example.org/fhir/StructureDefinition/cibmtr-ancestry). Use the special-url parameter if you really mean for it not to match
fsh-generated\resources\ValueSet-cibmtr-ancestry-vs.jsonConformance resource D:\IG\0515_Final\build\fsh-generated\resources\ValueSet-cibmtr-ancestry-vs.json - the canonical URL (http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/cibmtr-ancestry-vs) does not match the URL (https://termservices.nmdp.org/atlas/#/conceptset/136/expression). Use the special-url parameter if you really mean for it not to match

SD_ED_EXPERIMENTAL_BINDING

fsh-generated\resources\StructureDefinition-cibmtr-additional-peri-transplant-medication.jsonThe definition for the element 'Medication.code.coding' binds to the value set 'http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/med-addition-peri-transplant-vs' which is experimental, but this structure is not labeled as experimental
fsh-generated\resources\StructureDefinition-cibmtr-additional-peri-transplant-medication.jsonThe definition for the element 'Medication.code.coding' binds to the value set 'http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/med-addition-peri-transplant-vs' which is experimental, but this structure is not labeled as experimental
fsh-generated\resources\StructureDefinition-cibmtr-gvhd-prophylaxis-medication.jsonThe definition for the element 'Medication.code.coding' binds to the value set 'http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/med-gvhd-prophylaxis-vs' which is experimental, but this structure is not labeled as experimental
fsh-generated\resources\StructureDefinition-cibmtr-gvhd-prophylaxis-medication.jsonThe definition for the element 'Medication.code.coding' binds to the value set 'http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/med-gvhd-prophylaxis-vs' which is experimental, but this structure is not labeled as experimental
fsh-generated\resources\StructureDefinition-cibmtr-mobilizing-agent-medication.jsonThe definition for the element 'Medication.code.coding' binds to the value set 'http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/med-mobilizing-agents-vs' which is experimental, but this structure is not labeled as experimental
fsh-generated\resources\StructureDefinition-cibmtr-mobilizing-agent-medication.jsonThe definition for the element 'Medication.code.coding' binds to the value set 'http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/med-mobilizing-agents-vs' which is experimental, but this structure is not labeled as experimental
fsh-generated\resources\StructureDefinition-cibmtr-post-hct-disease-therapy-planned-medication.jsonThe definition for the element 'Medication.code.coding' binds to the value set 'http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/med-post-hct-disease-therapy-planned-vs' which is experimental, but this structure is not labeled as experimental
fsh-generated\resources\StructureDefinition-cibmtr-post-hct-disease-therapy-planned-medication.jsonThe definition for the element 'Medication.code.coding' binds to the value set 'http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/med-post-hct-disease-therapy-planned-vs' which is experimental, but this structure is not labeled as experimental
fsh-generated\resources\StructureDefinition-cibmtr-prep-regimen-medication.jsonThe definition for the element 'Medication.code.coding' binds to the value set 'http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/med-prep-regimen-vs' which is experimental, but this structure is not labeled as experimental
fsh-generated\resources\StructureDefinition-cibmtr-prep-regimen-medication.jsonThe definition for the element 'Medication.code.coding' binds to the value set 'http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/med-prep-regimen-vs' which is experimental, but this structure is not labeled as experimental
fsh-generated\resources\StructureDefinition-cibmtr-prior-exposure-medication.jsonThe definition for the element 'Medication.code.coding' binds to the value set 'http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/med-prior-exposure-vs' which is experimental, but this structure is not labeled as experimental
fsh-generated\resources\StructureDefinition-cibmtr-prior-exposure-medication.jsonThe definition for the element 'Medication.code.coding' binds to the value set 'http://fhir.nmdp.org/ig/cibmtr-reporting/ValueSet/med-prior-exposure-vs' which is experimental, but this structure is not labeled as experimental

SD_PATH_SLICING_DEPRECATED

fsh-generated\resources\StructureDefinition-cibmtr-additional-peri-transplant-medication.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-cytogenetics.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-cytogenetics.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-cytogenetics.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-gvhd-prophylaxis-medication.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-medication.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-medication.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-medication-administration.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-medication-administration.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-medication-request.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-medication-request.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-medication-request.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-medications.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-medications.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-medications.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-mobilizing-agent-medication.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-obs-priority-variables.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-observation-lab.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-observation-lab.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-patient.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-patient.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-patient.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-patient.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-post-hct-disease-therapy-planned-medication.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-prep-regimen-medication.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-prior-exposure-medication.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs-height.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs-height.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs-weight.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs-weight.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)

TERMINOLOGY_TX_SYSTEM_NOT_USABLE

fsh-generated\resources\Patient-PatientExample3.jsonThe definition for the Code System with URI 'urn:oid:2.16.840.1.113883.6.238' doesn't provide any codes so the code cannot be validated
fsh-generated\resources\Patient-PatientExample4.jsonThe definition for the Code System with URI 'urn:oid:2.16.840.1.113883.6.238' doesn't provide any codes so the code cannot be validated
fsh-generated\resources\Patient-PatientExample5.jsonThe definition for the Code System with URI 'urn:oid:2.16.840.1.113883.6.238' doesn't provide any codes so the code cannot be validated
fsh-generated\resources\Patient-PatientExample5.jsonThe definition for the Code System with URI 'urn:oid:2.16.840.1.113883.6.238' doesn't provide any codes so the code cannot be validated
fsh-generated\resources\Patient-PatientExample5.jsonThe definition for the Code System with URI 'urn:oid:2.16.840.1.113883.6.238' doesn't provide any codes so the code cannot be validated

TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS

fsh-generated\resources\StructureDefinition-cibmtr-additional-peri-transplant-medication.jsonThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240606', found versions: 20170601 (from us.nlm.vsac#0.11.0), 20240606 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4|20240606'
fsh-generated\resources\StructureDefinition-cibmtr-ancestry.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-race'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-race' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-race|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-ancestry.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-race'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-race' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-race|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-cytogenetics.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/observation-secondaryFinding'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 1.0.0 (from hl7.fhir.uv.extensions.r4#1.0.0), 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.1.0-cibuild (from hl7.fhir.uv.extensions.r4#5.1.0-snapshot1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/observation-secondaryFinding' to 'http://hl7.org/fhir/StructureDefinition/observation-secondaryFinding|5.3.0'
fsh-generated\resources\StructureDefinition-cibmtr-cytogenetics.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/bodySite'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 1.0.0 (from hl7.fhir.uv.extensions.r4#1.0.0), 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.1.0-cibuild (from hl7.fhir.uv.extensions.r4#5.1.0-snapshot1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/bodySite' to 'http://hl7.org/fhir/StructureDefinition/bodySite|5.3.0'
fsh-generated\resources\StructureDefinition-cibmtr-gvhd-prophylaxis-medication.jsonThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240606', found versions: 20170601 (from us.nlm.vsac#0.11.0), 20240606 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4|20240606'
fsh-generated\resources\StructureDefinition-cibmtr-medication.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medication'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medication' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medication|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medication.jsonThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240606', found versions: 20170601 (from us.nlm.vsac#0.11.0), 20240606 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4|20240606'
fsh-generated\resources\StructureDefinition-cibmtr-medication-administration.jsonThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240606', found versions: 20170601 (from us.nlm.vsac#0.11.0), 20240606 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4|20240606'
fsh-generated\resources\StructureDefinition-cibmtr-medication-administration.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-condition-problems-health-concerns'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-condition-problems-health-concerns' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-condition-problems-health-concerns|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medication-request.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medicationrequest'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medicationrequest' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medicationrequest|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medication-request.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medication-request.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medication-request.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medication-request.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitionerrole'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitionerrole' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitionerrole|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medication-request.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medication-request.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medication'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medication' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medication|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medication-request.jsonThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240606', found versions: 20170601 (from us.nlm.vsac#0.11.0), 20240606 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4|20240606'
fsh-generated\resources\StructureDefinition-cibmtr-medication-request.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-encounter'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-encounter' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-encounter|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medication-request.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medication-request.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medication-request.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-condition-problems-health-concerns'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-condition-problems-health-concerns' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-condition-problems-health-concerns|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medication-request.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-ActSubstanceAdminSubstitutionCode'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.2.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-ActSubstanceAdminSubstitutionCode' to 'http://terminology.hl7.org/ValueSet/v3-ActSubstanceAdminSubstitutionCode|3.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medication-request.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-SubstanceAdminSubstitutionReason'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.2.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-SubstanceAdminSubstitutionReason' to 'http://terminology.hl7.org/ValueSet/v3-SubstanceAdminSubstitutionReason|3.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medications.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medicationrequest'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medicationrequest' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medicationrequest|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medications.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medications.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medications.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medications.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitionerrole'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitionerrole' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitionerrole|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medications.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medications.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medication'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medication' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-medication|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medications.jsonThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240606', found versions: 20170601 (from us.nlm.vsac#0.11.0), 20240606 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4|20240606'
fsh-generated\resources\StructureDefinition-cibmtr-medications.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-encounter'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-encounter' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-encounter|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medications.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medications.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medications.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-condition-problems-health-concerns'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-condition-problems-health-concerns' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-condition-problems-health-concerns|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medications.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-ActSubstanceAdminSubstitutionCode'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.2.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-ActSubstanceAdminSubstitutionCode' to 'http://terminology.hl7.org/ValueSet/v3-ActSubstanceAdminSubstitutionCode|3.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-medications.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-SubstanceAdminSubstitutionReason'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.2.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-SubstanceAdminSubstitutionReason' to 'http://terminology.hl7.org/ValueSet/v3-SubstanceAdminSubstitutionReason|3.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-mobilizing-agent-medication.jsonThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240606', found versions: 20170601 (from us.nlm.vsac#0.11.0), 20240606 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4|20240606'
fsh-generated\resources\StructureDefinition-cibmtr-obs-priority-variables.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-obs-priority-variables.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/ValueSet/us-core-clinical-result-observation-category'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/ValueSet/us-core-clinical-result-observation-category' to 'http://hl7.org/fhir/us/core/ValueSet/us-core-clinical-result-observation-category|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-obs-priority-variables.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/ValueSet/us-core-laboratory-test-codes'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/ValueSet/us-core-laboratory-test-codes' to 'http://hl7.org/fhir/us/core/ValueSet/us-core-laboratory-test-codes|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-obs-priority-variables.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-obs-priority-variables.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-location'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-location' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-location|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-obs-priority-variables.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-encounter'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-encounter' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-encounter|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-obs-priority-variables.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-obs-priority-variables.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-obs-priority-variables.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-obs-priority-variables.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-obs-priority-variables.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-obs-priority-variables.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-obs-priority-variables.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-obs-priority-variables.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-obs-priority-variables.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-specimen'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-specimen' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-specimen|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-obs-priority-variables.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-observation-lab.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-observation-lab.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-observation-lab.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/ValueSet/us-core-clinical-result-observation-category'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/ValueSet/us-core-clinical-result-observation-category' to 'http://hl7.org/fhir/us/core/ValueSet/us-core-clinical-result-observation-category|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-observation-lab.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/ValueSet/us-core-laboratory-test-codes'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/ValueSet/us-core-laboratory-test-codes' to 'http://hl7.org/fhir/us/core/ValueSet/us-core-laboratory-test-codes|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-observation-lab.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-observation-lab.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-location'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-location' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-location|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-observation-lab.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-encounter'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-encounter' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-encounter|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-observation-lab.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-observation-lab.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-observation-lab.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-observation-lab.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-observation-lab.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-observation-lab.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-observation-lab.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-observation-lab.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-observation-lab.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-specimen'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-specimen' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-specimen|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-observation-lab.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-patient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-patient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-race'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-race' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-race|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-patient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-ethnicity'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-ethnicity' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-ethnicity|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-patient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-tribal-affiliation'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-tribal-affiliation' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-tribal-affiliation|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-patient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-sex'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-sex' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-sex|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-patient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 1.0.0 (from hl7.fhir.uv.extensions.r4#1.0.0), 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.1.0-cibuild (from hl7.fhir.uv.extensions.r4#5.1.0-snapshot1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName' to 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName|5.3.0'
fsh-generated\resources\StructureDefinition-cibmtr-patient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/patient-birthPlace'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 1.0.0 (from hl7.fhir.uv.extensions.r4#1.0.0), 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.1.0-cibuild (from hl7.fhir.uv.extensions.r4#5.1.0-snapshot1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/patient-birthPlace' to 'http://hl7.org/fhir/StructureDefinition/patient-birthPlace|5.3.0'
fsh-generated\resources\StructureDefinition-cibmtr-patient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-patient.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/USPS-State'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '2.0.0', found versions: 1.0.0 (from hl7.terminology.r4#6.4.0), 2.0.0 (from hl7.terminology.r4#7.2.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/USPS-State' to 'http://terminology.hl7.org/ValueSet/USPS-State|2.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-patient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 1.0.0 (from hl7.fhir.uv.extensions.r4#1.0.0), 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.1.0-cibuild (from hl7.fhir.uv.extensions.r4#5.1.0-snapshot1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName' to 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName|5.3.0'
fsh-generated\resources\StructureDefinition-cibmtr-patient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/patient-birthPlace'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0', found versions: 1.0.0 (from hl7.fhir.uv.extensions.r4#1.0.0), 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.1.0-cibuild (from hl7.fhir.uv.extensions.r4#5.1.0-snapshot1), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0), 5.3.0 (from hl7.fhir.uv.extensions.r4#5.3.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/patient-birthPlace' to 'http://hl7.org/fhir/StructureDefinition/patient-birthPlace|5.3.0'
fsh-generated\resources\StructureDefinition-cibmtr-post-hct-disease-therapy-planned-medication.jsonThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240606', found versions: 20170601 (from us.nlm.vsac#0.11.0), 20240606 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4|20240606'
fsh-generated\resources\StructureDefinition-cibmtr-prep-regimen-medication.jsonThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240606', found versions: 20170601 (from us.nlm.vsac#0.11.0), 20240606 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4|20240606'
fsh-generated\resources\StructureDefinition-cibmtr-prior-exposure-medication.jsonThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240606', found versions: 20170601 (from us.nlm.vsac#0.11.0), 20240606 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1010.4|20240606'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs.jsonThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240322', found versions: 20210630 (from us.nlm.vsac#0.11.0), 20240322 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62|20240322'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs-height.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-body-height'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-body-height' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-body-height|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs-height.jsonThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240322', found versions: 20210630 (from us.nlm.vsac#0.11.0), 20240322 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62|20240322'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs-height.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs-height.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs-height.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs-height.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs-height.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs-height.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs-height.jsonThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240322', found versions: 20210630 (from us.nlm.vsac#0.11.0), 20240322 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62|20240322'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs-weight.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-body-weight'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-body-weight' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-body-weight|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs-weight.jsonThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240322', found versions: 20210630 (from us.nlm.vsac#0.11.0), 20240322 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62|20240322'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs-weight.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs-weight.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs-weight.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs-weight.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs-weight.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs-weight.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '8.0.0', found versions: 6.1.0 (from hl7.fhir.us.core#6.1.0), 8.0.0 (from hl7.fhir.us.core#8.0.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson' to 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-relatedperson|8.0.0'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs-weight.jsonThere are multiple different potential matches for the url 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '20240322', found versions: 20210630 (from us.nlm.vsac#0.11.0), 20240322 (from us.nlm.vsac#0.23.0). Suggested fix: change the canonical reference from 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62' to 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.88.12.80.62|20240322'

TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVE

fsh-generated\resources\StructureDefinition-cibmtr-vital-signs.jsonA definition could not be found for Canonical URL 'https://vsac.nlm.nih.gov/valueset/2.16.840.1.113762.1.4.1295.1/expansion'
fsh-generated\resources\StructureDefinition-cibmtr-vital-signs.jsonA definition could not be found for Canonical URL 'https://vsac.nlm.nih.gov/valueset/2.16.840.1.113762.1.4.1295.1/expansion'

TYPE_SPECIFIC_CHECKS_DT_QTY_UCUM_ANNOTATIONS

fsh-generated\resources\Observation-CMVDNAViralLoadCopiesmL.jsonUCUM Codes that contain human readable annotations like {copies} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked
fsh-generated\resources\Observation-CMVDNAViralLoadCopiesmL.jsonUCUM Codes that contain human readable annotations like {copies} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked
fsh-generated\resources\Observation-CMVDNAViralLoadCopiesmL.jsonUCUM Codes that contain human readable annotations like {copies} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked

Type_Specific_Checks_DT_URL_Resolve

fsh-generated\resources\Patient-PatientExample1.jsonNo definition could be found for URL value 'http://terminology.cibmtr.org/identifier/CRID'
fsh-generated\resources\Patient-PatientExample3.jsonNo definition could be found for URL value 'http://terminology.cibmtr.org/identifier/CRID'
fsh-generated\resources\Patient-PatientExample3.jsonNo definition could be found for URL value 'http://terminology.cibmtr.org/identifier/transplant-center'
fsh-generated\resources\Patient-PatientExample4.jsonNo definition could be found for URL value 'http://terminology.cibmtr.org/identifier/CRID'
fsh-generated\resources\Patient-PatientExample4.jsonNo definition could be found for URL value 'http://terminology.cibmtr.org/identifier/transplant-center'
fsh-generated\resources\Patient-PatientExample5.jsonNo definition could be found for URL value 'http://terminology.cibmtr.org/identifier/CRID'
fsh-generated\resources\Patient-PatientExample5.jsonNo definition could be found for URL value 'http://terminology.cibmtr.org/identifier/transplant-center'
fsh-generated\resources\Patient-PatientExample6.jsonNo definition could be found for URL value 'http://terminology.cibmtr.org/identifier/CRID'

UNKNOWN_CODESYSTEM

fsh-generated\resources\Medication-Medication-Cyclophosphamide-Example.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Medication-Medication-Etoposide-Example.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Medication-Medication-GVHD-Prophylaxis-Example.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Medication-Medication-Mobilizing-Agent-Example.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Medication-Medication-Peri-Transplant-Example.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Medication-Medication-Post-HCT-Disease-Therapy-Example.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Medication-Medication-Prep-Regimen-Example.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Medication-Medication-PriorExposure-Example.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\MedicationAdministration-MedicationAdministration-Example1.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\MedicationAdministration-MedicationAdministration-Example2.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\MedicationRequest-MedicationRequest-Etoposide-Example.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Observation-ABOBloodGroupObservationLOINC.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Observation-ABOBloodGroupObservationSNOMED.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Observation-ABORhObservationLOINC.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Observation-ABORhObservationSNOMED.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Observation-AlbuminObservation.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Observation-BasophilsObservation.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Observation-BodyHeight.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Observation-BodyWeight.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Observation-CMVDNAViralLoadCopiesmL.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Observation-CMVDNAViralLoadIUmL.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Observation-CMVIgAbPresenceSNOMED.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Observation-CMVIgGAbPresenceLOINC.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Observation-CMVIgMAbPresenceLOINC.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Observation-CMVIgMAbPresenceSNOMED.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Observation-Cytogenetics-Example-1.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Observation-Cytogenetics-Example-1.jsonA definition for CodeSystem 'https://iscn.karger.com' could not be found, so the code cannot be validated
fsh-generated\resources\Observation-EosinophilsObservation.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Observation-HemoglobinObservation.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Observation-LeukocytesObservation.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Observation-MetamyelocytesObservation.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Observation-NeutrophilsObservation.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Patient-PatientExample1.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Patient-PatientExample2.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Patient-PatientExample3.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Patient-PatientExample4.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Patient-PatientExample5.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated
fsh-generated\resources\Patient-PatientExample6.jsonA definition for CodeSystem 'http://terminology.cibmtr.org/codesystem/transplant-center' could not be found, so the code cannot be validated

UNKNOWN_CODESYSTEM_VERSION

fsh-generated\resources\Medication-Medication-Cyclophosphamide-Example.jsonA definition for CodeSystem 'http://www.nlm.nih.gov/research/umls/rxnorm' version '05052025' could not be found, so the code cannot be validated. Valid versions: 03022026
fsh-generated\resources\Medication-Medication-Etoposide-Example.jsonA definition for CodeSystem 'http://www.nlm.nih.gov/research/umls/rxnorm' version '05052025' could not be found, so the code cannot be validated. Valid versions: 03022026
fsh-generated\resources\Medication-Medication-GVHD-Prophylaxis-Example.jsonA definition for CodeSystem 'http://www.nlm.nih.gov/research/umls/rxnorm' version '05052025' could not be found, so the code cannot be validated. Valid versions: 03022026
fsh-generated\resources\Medication-Medication-Mobilizing-Agent-Example.jsonA definition for CodeSystem 'http://www.nlm.nih.gov/research/umls/rxnorm' version '05052025' could not be found, so the code cannot be validated. Valid versions: 03022026
fsh-generated\resources\Medication-Medication-Peri-Transplant-Example.jsonA definition for CodeSystem 'http://www.nlm.nih.gov/research/umls/rxnorm' version '05052025' could not be found, so the code cannot be validated. Valid versions: 03022026
fsh-generated\resources\Medication-Medication-Post-HCT-Disease-Therapy-Example.jsonA definition for CodeSystem 'http://www.nlm.nih.gov/research/umls/rxnorm' version '05052025' could not be found, so the code cannot be validated. Valid versions: 03022026
fsh-generated\resources\Medication-Medication-Prep-Regimen-Example.jsonA definition for CodeSystem 'http://www.nlm.nih.gov/research/umls/rxnorm' version '05052025' could not be found, so the code cannot be validated. Valid versions: 03022026
fsh-generated\resources\Medication-Medication-PriorExposure-Example.jsonA definition for CodeSystem 'http://www.nlm.nih.gov/research/umls/rxnorm' version '05052025' could not be found, so the code cannot be validated. Valid versions: 03022026
fsh-generated\resources\MedicationAdministration-MedicationAdministration-Example2.jsonA definition for CodeSystem 'http://www.nlm.nih.gov/research/umls/rxnorm' version '05052025' could not be found, so the code cannot be validated. Valid versions: 03022026

VALUESET_CODE_CONCEPT_HINT

fsh-generated\resources\ValueSet-auto-differential-blood-vs.jsonWrong Display Name 'Neutrophils/100 leukocytes in Blood by Automated count' for http://loinc.org#770-8. Valid display is one of 3 choices: 'Neutrophils/Leukocytes in Blood by Automated count' (en-US), 'Neutrophils/Leukocytes in Blood by Automated count' (en-US) or 'Neutrophils NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-auto-differential-blood-vs.jsonWrong Display Name 'Band form neutrophils/100 leukocytes in Blood by Automated count' for http://loinc.org#35332-6. Valid display is one of 3 choices: 'Band form neutrophils/Leukocytes in Blood by Automated count' (en-US), 'Band form neutrophils/Leukocytes in Blood by Automated count' (en-US) or 'Neuts Band NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-auto-differential-blood-vs.jsonWrong Display Name 'Granulocytes/100 leukocytes in Blood by Automated count' for http://loinc.org#19023-1. Valid display is one of 3 choices: 'Granulocytes/Leukocytes in Blood by Automated count' (en-US), 'Granulocytes/Leukocytes in Blood by Automated count' (en-US) or 'Granulocytes NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-auto-differential-blood-vs.jsonWrong Display Name 'Lymphocytes/100 leukocytes in Blood by Automated count' for http://loinc.org#736-9. Valid display is one of 3 choices: 'Lymphocytes/Leukocytes in Blood by Automated count' (en-US), 'Lymphocytes/Leukocytes in Blood by Automated count' (en-US) or 'Lymphocytes NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-auto-differential-blood-vs.jsonWrong Display Name 'Variant lymphocytes/100 leukocytes in Blood by Automated count' for http://loinc.org#42250-1. Valid display is one of 3 choices: 'Variant lymphocytes/Leukocytes in Blood by Automated count' (en-US), 'Variant lymphocytes/Leukocytes in Blood by Automated count' (en-US) or 'Variant Lymphs NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-auto-differential-blood-vs.jsonWrong Display Name 'Monocytes/100 leukocytes in Blood by Automated count' for http://loinc.org#5905-5. Valid display is one of 3 choices: 'Monocytes/Leukocytes in Blood by Automated count' (en-US), 'Monocytes/Leukocytes in Blood by Automated count' (en-US) or 'Monocytes NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-auto-differential-blood-vs.jsonWrong Display Name 'Eosinophils/100 leukocytes in Blood by Automated count' for http://loinc.org#713-8. Valid display is one of 3 choices: 'Eosinophils/Leukocytes in Blood by Automated count' (en-US), 'Eosinophils/Leukocytes in Blood by Automated count' (en-US) or 'Eosinophil NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-auto-differential-blood-vs.jsonWrong Display Name 'Basophils/100 leukocytes in Blood by Automated count' for http://loinc.org#706-2. Valid display is one of 3 choices: 'Basophils/Leukocytes in Blood by Automated count' (en-US), 'Basophils/Leukocytes in Blood by Automated count' (en-US) or 'Basophils NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-auto-differential-blood-vs.jsonWrong Display Name 'Other cells/100 leukocytes in Blood by Automated count' for http://loinc.org#58409-4. Valid display is one of 3 choices: 'Other cells/Leukocytes in Blood by Automated count' (en-US), 'Other cells/Leukocytes in Blood by Automated count' (en-US) or 'Other cells NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cbc-blood-automated-vs.jsonWrong Display Name 'MCV [Entitic volume] by Automated count' for http://loinc.org#787-2. Valid display is one of 3 choices: 'MCV [Entitic mean volume] in Red Blood Cells by Automated count' (en-US), 'MCV [Entitic mean volume] in Red Blood Cells by Automated count' (en-US) or 'MCV RBC Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cbc-blood-automated-vs.jsonWrong Display Name 'MCHC [Mass/volume] by Automated count' for http://loinc.org#786-4. Valid display is one of 3 choices: 'MCHC [Entitic Mass/volume] in Red Blood Cells by Automated count' (en-US), 'MCHC [Entitic Mass/volume] in Red Blood Cells by Automated count' (en-US) or 'MCHC RBC Auto-EntMCnc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cbc-blood-automated-vs.jsonWrong Display Name 'Erythrocyte distribution width [Ratio] by Automated count' for http://loinc.org#788-0. Valid display is one of 3 choices: 'Erythrocyte [DistWidth] in Blood by Automated count' (en-US), 'Erythrocyte [DistWidth] in Blood by Automated count' (en-US) or 'Erythrocyte DistWidth Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cbc-blood-automated-vs.jsonWrong Display Name 'Platelet mean volume [Entitic volume] in Blood by Automated count' for http://loinc.org#32623-1. Valid display is one of 3 choices: 'Platelet [Entitic mean volume] in Blood by Automated count' (en-US), 'Platelet [Entitic mean volume] in Blood by Automated count' (en-US) or 'PMV Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cbc-w-differential-unspecified-blood-vs.jsonWrong Display Name 'Hematocrit [Volume Fraction] of Blood' for http://loinc.org#20570-8. Valid display is one of 3 choices: 'Hematocrit [Volume Fraction] of Blood by calculation' (en-US), 'Hematocrit [Volume Fraction] of Blood by calculation' (en-US) or 'Hct VFr Bld Calc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cbc-w-differential-unspecified-blood-vs.jsonWrong Display Name 'MCHC [Mass/volume]' for http://loinc.org#28540-3. Valid display is one of 3 choices: 'MCHC [Entitic Mass/volume] in Red Blood Cells' (en-US), 'MCHC [Entitic Mass/volume] in Red Blood Cells' (en-US) or 'MCHC RBC-EntMCnc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cbc-w-differential-unspecified-blood-vs.jsonWrong Display Name 'Platelet mean volume [Entitic volume] in Blood' for http://loinc.org#28542-9. Valid display is one of 3 choices: 'Platelet [Entitic mean volume] in Blood' (en-US), 'Platelet [Entitic mean volume] in Blood' (en-US) or 'PMV Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cbc-w-differential-unspecified-blood-vs.jsonWrong Display Name 'Erythrocyte distribution width [Entitic volume]' for http://loinc.org#30384-2. Valid display is one of 3 choices: 'Deprecated Erythrocyte distribution width [Entitic volume]' (en-US), 'Deprecated Erythrocyte distribution width [Entitic volume]' (en-US) or 'Deprecated RDW RBC' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cbc-w-differential-unspecified-blood-vs.jsonWrong Display Name 'Erythrocyte distribution width [Ratio]' for http://loinc.org#30385-9. Valid display is one of 3 choices: 'Erythrocyte [DistWidth] in Blood' (en-US), 'Erythrocyte [DistWidth] in Blood' (en-US) or 'Erythrocyte DistWidth Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cbc-w-differential-unspecified-blood-vs.jsonWrong Display Name 'MCV [Entitic volume]' for http://loinc.org#30428-7. Valid display is one of 3 choices: 'MCV [Entitic mean volume] in Red Blood Cells' (en-US), 'MCV [Entitic mean volume] in Red Blood Cells' (en-US) or 'MCV RBC' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Band form neutrophils/100 leukocytes in Blood' for http://loinc.org#26508-2. Valid display is one of 3 choices: 'Band form neutrophils/Leukocytes in Blood' (en-US), 'Band form neutrophils/Leukocytes in Blood' (en-US) or 'Neuts Band NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Band form neutrophils/100 leukocytes in Blood by Automated count' for http://loinc.org#35332-6. Valid display is one of 3 choices: 'Band form neutrophils/Leukocytes in Blood by Automated count' (en-US), 'Band form neutrophils/Leukocytes in Blood by Automated count' (en-US) or 'Neuts Band NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Band form neutrophils/100 leukocytes in Blood by Manual count' for http://loinc.org#764-1. Valid display is one of 3 choices: 'Band form neutrophils/Leukocytes in Blood by Manual count' (en-US), 'Band form neutrophils/Leukocytes in Blood by Manual count' (en-US) or 'Neuts Band NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Basophils/100 leukocytes in Blood' for http://loinc.org#30180-4. Valid display is one of 3 choices: 'Basophils/Leukocytes in Blood' (en-US), 'Basophils/Leukocytes in Blood' (en-US) or 'Basophils NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Basophils/100 leukocytes in Blood by Automated count' for http://loinc.org#706-2. Valid display is one of 3 choices: 'Basophils/Leukocytes in Blood by Automated count' (en-US), 'Basophils/Leukocytes in Blood by Automated count' (en-US) or 'Basophils NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Basophils/100 leukocytes in Blood by Manual count' for http://loinc.org#707-0. Valid display is one of 3 choices: 'Basophils/Leukocytes in Blood by Manual count' (en-US), 'Basophils/Leukocytes in Blood by Manual count' (en-US) or 'Basophils NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Blasts/100 leukocytes in Blood' for http://loinc.org#26446-5. Valid display is one of 3 choices: 'Blasts/Leukocytes in Blood' (en-US), 'Blasts/Leukocytes in Blood' (en-US) or 'Blasts NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Blasts/100 leukocytes in Blood by Manual count' for http://loinc.org#709-6. Valid display is one of 3 choices: 'Blasts/Leukocytes in Blood by Manual count' (en-US), 'Blasts/Leukocytes in Blood by Manual count' (en-US) or 'Blasts NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Eosinophils/100 leukocytes in Blood' for http://loinc.org#26450-7. Valid display is one of 3 choices: 'Eosinophils/Leukocytes in Blood' (en-US), 'Eosinophils/Leukocytes in Blood' (en-US) or 'Eosinophil NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Eosinophils/100 leukocytes in Blood by Automated count' for http://loinc.org#713-8. Valid display is one of 3 choices: 'Eosinophils/Leukocytes in Blood by Automated count' (en-US), 'Eosinophils/Leukocytes in Blood by Automated count' (en-US) or 'Eosinophil NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Eosinophils/100 leukocytes in Blood by Manual count' for http://loinc.org#714-6. Valid display is one of 3 choices: 'Eosinophils/Leukocytes in Blood by Manual count' (en-US), 'Eosinophils/Leukocytes in Blood by Manual count' (en-US) or 'Eosinophil NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Hematocrit [Volume Fraction] of Blood' for http://loinc.org#20570-8. Valid display is one of 3 choices: 'Hematocrit [Volume Fraction] of Blood by calculation' (en-US), 'Hematocrit [Volume Fraction] of Blood by calculation' (en-US) or 'Hct VFr Bld Calc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Hematocrit [Pure volume fraction] of Capillary blood' for http://loinc.org#71831-2. Valid display is one of 3 choices: 'Hematocrit [Pure volume fraction] of Capillary blood by calculation' (en-US), 'Hematocrit [Pure volume fraction] of Capillary blood by calculation' (en-US) or 'Hct VFr.DF BldC Calc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Hematocrit [Pure volume fraction] of Venous blood' for http://loinc.org#71829-6. Valid display is one of 3 choices: 'Hematocrit [Pure volume fraction] of Venous blood by calculation' (en-US), 'Hematocrit [Pure volume fraction] of Venous blood by calculation' (en-US) or 'Hct VFr.DF BldV Calc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Hematocrit [Volume Fraction] of Capillary blood' for http://loinc.org#42908-4. Valid display is one of 3 choices: 'Hematocrit [Volume Fraction] of Capillary blood by calculation' (en-US), 'Hematocrit [Volume Fraction] of Capillary blood by calculation' (en-US) or 'Hct VFr BldC Calc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Hematocrit [Volume Fraction] of Venous blood' for http://loinc.org#41654-5. Valid display is one of 3 choices: 'Hematocrit [Volume Fraction] of Venous blood by calculation' (en-US), 'Hematocrit [Volume Fraction] of Venous blood by calculation' (en-US) or 'Hct VFr BldV Calc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Lymphocytes/100 leukocytes in Blood' for http://loinc.org#26478-8. Valid display is one of 3 choices: 'Lymphocytes/Leukocytes in Blood' (en-US), 'Lymphocytes/Leukocytes in Blood' (en-US) or 'Lymphocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Lymphocytes/100 leukocytes in Blood by Automated count' for http://loinc.org#736-9. Valid display is one of 3 choices: 'Lymphocytes/Leukocytes in Blood by Automated count' (en-US), 'Lymphocytes/Leukocytes in Blood by Automated count' (en-US) or 'Lymphocytes NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Lymphocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#737-7. Valid display is one of 3 choices: 'Lymphocytes/Leukocytes in Blood by Manual count' (en-US), 'Lymphocytes/Leukocytes in Blood by Manual count' (en-US) or 'Lymphocytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Metamyelocytes/100 leukocytes in Blood' for http://loinc.org#28541-1. Valid display is one of 3 choices: 'Metamyelocytes/Leukocytes in Blood' (en-US), 'Metamyelocytes/Leukocytes in Blood' (en-US) or 'Metamyelocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Metamyelocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#740-1. Valid display is one of 3 choices: 'Metamyelocytes/Leukocytes in Blood by Manual count' (en-US), 'Metamyelocytes/Leukocytes in Blood by Manual count' (en-US) or 'Metamyelocytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Monocytes/100 leukocytes in Blood' for http://loinc.org#26485-3. Valid display is one of 3 choices: 'Monocytes/Leukocytes in Blood' (en-US), 'Monocytes/Leukocytes in Blood' (en-US) or 'Monocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Monocytes/100 leukocytes in Blood by Automated count' for http://loinc.org#5905-5. Valid display is one of 3 choices: 'Monocytes/Leukocytes in Blood by Automated count' (en-US), 'Monocytes/Leukocytes in Blood by Automated count' (en-US) or 'Monocytes NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Monocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#744-3. Valid display is one of 3 choices: 'Monocytes/Leukocytes in Blood by Manual count' (en-US), 'Monocytes/Leukocytes in Blood by Manual count' (en-US) or 'Monocytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Myeloblasts/100 leukocytes in Blood' for http://loinc.org#30445-1. Valid display is one of 3 choices: 'Myeloblasts/Leukocytes in Blood' (en-US), 'Myeloblasts/Leukocytes in Blood' (en-US) or 'Myeloblasts NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Myeloblasts/100 leukocytes in Blood by Manual count' for http://loinc.org#747-6. Valid display is one of 3 choices: 'Myeloblasts/Leukocytes in Blood by Manual count' (en-US), 'Myeloblasts/Leukocytes in Blood by Manual count' (en-US) or 'Myeloblasts NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Myelocytes/100 leukocytes in Blood' for http://loinc.org#26498-6. Valid display is one of 3 choices: 'Myelocytes/Leukocytes in Blood' (en-US), 'Myelocytes/Leukocytes in Blood' (en-US) or 'Myelocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Myelocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#749-2. Valid display is one of 3 choices: 'Myelocytes/Leukocytes in Blood by Manual count' (en-US), 'Myelocytes/Leukocytes in Blood by Manual count' (en-US) or 'Myelocytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Neutrophils/100 leukocytes in Blood' for http://loinc.org#26511-6. Valid display is one of 3 choices: 'Neutrophils/Leukocytes in Blood' (en-US), 'Neutrophils/Leukocytes in Blood' (en-US) or 'Neutrophils NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Neutrophils/100 leukocytes in Blood by Automated count' for http://loinc.org#770-8. Valid display is one of 3 choices: 'Neutrophils/Leukocytes in Blood by Automated count' (en-US), 'Neutrophils/Leukocytes in Blood by Automated count' (en-US) or 'Neutrophils NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Neutrophils/100 leukocytes in Blood by Manual count' for http://loinc.org#23761-0. Valid display is one of 3 choices: 'Neutrophils/Leukocytes in Blood by Manual count' (en-US), 'Neutrophils/Leukocytes in Blood by Manual count' (en-US) or 'Neutrophils NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Plasma cells/100 leukocytes in Blood' for http://loinc.org#13047-6. Valid display is one of 3 choices: 'Plasma cells/Leukocytes in Blood' (en-US), 'Plasma cells/Leukocytes in Blood' (en-US) or 'Plasma Cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Plasma cells/100 leukocytes in Blood by Manual count' for http://loinc.org#79426-3. Valid display is one of 3 choices: 'Plasma cells/Leukocytes in Blood by Manual count' (en-US), 'Plasma cells/Leukocytes in Blood by Manual count' (en-US) or 'Plasma Cells NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Platelet mean volume [Entitic volume] in Blood' for http://loinc.org#28542-9. Valid display is one of 3 choices: 'Platelet [Entitic mean volume] in Blood' (en-US), 'Platelet [Entitic mean volume] in Blood' (en-US) or 'PMV Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Platelet mean volume [Entitic volume] in Blood by Automated count' for http://loinc.org#32623-1. Valid display is one of 3 choices: 'Platelet [Entitic mean volume] in Blood by Automated count' (en-US), 'Platelet [Entitic mean volume] in Blood by Automated count' (en-US) or 'PMV Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Prolymphocytes/100 leukocytes in Blood' for http://loinc.org#30465-9. Valid display is one of 3 choices: 'Prolymphocytes/Leukocytes in Blood' (en-US), 'Prolymphocytes/Leukocytes in Blood' (en-US) or 'Prolymphocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Prolymphocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#6746-2. Valid display is one of 3 choices: 'Prolymphocytes/Leukocytes in Blood by Manual count' (en-US), 'Prolymphocytes/Leukocytes in Blood by Manual count' (en-US) or 'Prolymphocytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Promonocytes/100 leukocytes in Blood' for http://loinc.org#30466-7. Valid display is one of 3 choices: 'Promonocytes/Leukocytes in Blood' (en-US), 'Promonocytes/Leukocytes in Blood' (en-US) or 'Promonycytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Promonocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#13599-6. Valid display is one of 3 choices: 'Promonocytes/Leukocytes in Blood by Manual count' (en-US), 'Promonocytes/Leukocytes in Blood by Manual count' (en-US) or 'Promonycytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Promyelocytes/100 leukocytes in Blood' for http://loinc.org#26524-9. Valid display is one of 3 choices: 'Promyelocytes/Leukocytes in Blood' (en-US), 'Promyelocytes/Leukocytes in Blood' (en-US) or 'Promyelocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Promyelocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#783-1. Valid display is one of 3 choices: 'Promyelocytes/Leukocytes in Blood by Manual count' (en-US), 'Promyelocytes/Leukocytes in Blood by Manual count' (en-US) or 'Promyelocytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Blasts/100 cells in Bone marrow' for http://loinc.org#11150-0. Valid display is one of 3 choices: 'Blasts/cells in Bone marrow' (en-US), 'Blasts/cells in Bone marrow' (en-US) or 'Blasts NFr Mar' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Segmented neutrophils/100 leukocytes in Blood' for http://loinc.org#26505-8. Valid display is one of 3 choices: 'Segmented neutrophils/Leukocytes in Blood' (en-US), 'Segmented neutrophils/Leukocytes in Blood' (en-US) or 'Neuts Seg NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Segmented neutrophils/100 leukocytes in Blood by Automated count' for http://loinc.org#32200-8. Valid display is one of 3 choices: 'Segmented neutrophils/Leukocytes in Blood by Automated count' (en-US), 'Segmented neutrophils/Leukocytes in Blood by Automated count' (en-US) or 'Neuts Seg NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2021.jsonWrong Display Name 'Segmented neutrophils/100 leukocytes in Blood by Manual count' for http://loinc.org#769-0. Valid display is one of 3 choices: 'Segmented neutrophils/Leukocytes in Blood by Manual count' (en-US), 'Segmented neutrophils/Leukocytes in Blood by Manual count' (en-US) or 'Neuts Seg NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Albumin [Moles/volume] in Urine by Detection limit <= 3.0 mg/L' for http://loinc.org#77158-4. Valid display is one of 3 choices: 'Microalbumin [Moles/volume] in Urine by Detection limit <= 3.0 mg/L' (en-US), 'Microalbumin [Moles/volume] in Urine by Detection limit <= 3.0 mg/L' (en-US) or 'Microalbumin Ur DL<=3.0 mg/L-sCnc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Albumin [Mass/volume] in Urine by Detection limit <= 3.0 mg/L' for http://loinc.org#89999-7. Valid display is one of 3 choices: 'Microalbumin [Mass/volume] in Urine by Detection limit <= 3.0 mg/L' (en-US), 'Microalbumin [Mass/volume] in Urine by Detection limit <= 3.0 mg/L' (en-US) or 'Microalbumin Ur DL<=3.0 mg/L-mCnc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Cytomegalovirus DNA [Units/volume] (viral load) in Plasma by NAA with probe detection' for http://loinc.org#72493-0. Valid display is one of 3 choices: 'Cytomegalovirus DNA [Units/volume] (viral load) in Serum or Plasma by NAA with probe detection' (en-US), 'Cytomegalovirus DNA [Units/volume] (viral load) in Serum or Plasma by NAA with probe detection' (en-US) or 'CMV DNA SerPl NAA+probe-aCnc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Cytomegalovirus DNA [log units/volume] (viral load) in Plasma by NAA with probe detection' for http://loinc.org#72494-8. Valid display is one of 3 choices: 'Cytomegalovirus DNA [log units/volume] (viral load) in Serum or Plasma by NAA with probe detection' (en-US), 'Cytomegalovirus DNA [log units/volume] (viral load) in Serum or Plasma by NAA with probe detection' (en-US) or 'CMV DNA SerPl NAA+probe-Log IU' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Glomerular filtration rate/1.73 sq M.predicted among blacks [Volume Rate/Area] in DBS' for http://loinc.org#96591-3. Valid display is one of 3 choices: 'Glomerular filtration rate [Volume Rate/Area] in DBS by based on 1.73 sq M among black population' (en-US), 'Glomerular filtration rate [Volume Rate/Area] in DBS by based on 1.73 sq M among black population' (en-US) or 'GFR DBS based on 1.73 sq M among bla' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Glomerular filtration rate/1.73 sq M.predicted [Volume Rate/Area] in Serum, Plasma or Blood' for http://loinc.org#69405-9. Valid display is one of 3 choices: 'Glomerular filtration rate [Volume Rate/Area] in Serum, Plasma or Blood by based on 1.73 sq M' (en-US), 'Glomerular filtration rate [Volume Rate/Area] in Serum, Plasma or Blood by based on 1.73 sq M' (en-US) or 'GFR SerPlBld based on 1.73 sq M-ArVRat' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Glomerular filtration rate/1.73 sq M.predicted among non-blacks [Volume Rate/Area] in DBS' for http://loinc.org#96592-1. Valid display is one of 3 choices: 'Glomerular filtration rate [Volume Rate/Area] in DBS by based on 1.73 sq M among non black population' (en-US), 'Glomerular filtration rate [Volume Rate/Area] in DBS by based on 1.73 sq M among non black population' (en-US) or 'GFR DBS based on 1.73 sq M among n bl pp' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Glomerular filtration rate/1.73 sq M.predicted [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (Schwartz)' for http://loinc.org#50384-7. Valid display is one of 3 choices: 'Glomerular filtration rate [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (Schwartz)/1.73 sq M' (en-US), 'Glomerular filtration rate [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (Schwartz)/1.73 sq M' (en-US) or 'GFR SerPlBld Schwartz-ArVRat' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Glomerular filtration rate/1.73 sq M.predicted [Volume Rate/Area] in Serum, Plasma or Blood by Cystatin-based formula' for http://loinc.org#50210-4. Valid display is one of 3 choices: 'Glomerular filtration rate [Volume Rate/Area] in Serum, Plasma or Blood by Cystatin C-based formula/1.73 sq M' (en-US), 'Glomerular filtration rate [Volume Rate/Area] in Serum, Plasma or Blood by Cystatin C-based formula/1.73 sq M' (en-US) or 'GFR/BSA.pred SerPlBld Cys-based-ArV' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Glomerular filtration rate/1.73 sq M.predicted [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (CKD-EPI)' for http://loinc.org#62238-1. Valid display is one of 3 choices: 'Glomerular filtration rate [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (CKD-EPI)/1.73 sq M' (en-US), 'Glomerular filtration rate [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (CKD-EPI)/1.73 sq M' (en-US) or 'GFR SerPlBld Creatinine-bsd fmla CKD-EPI' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Glomerular filtration rate/1.73 sq M.predicted [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (MDRD)' for http://loinc.org#77147-7. Valid display is one of 3 choices: 'Glomerular filtration rate [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (MDRD)/1.73 sq M' (en-US), 'Glomerular filtration rate [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (MDRD)/1.73 sq M' (en-US) or 'GFRSerPlBld MDRD-ArVRat' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Glomerular filtration rate/1.73 sq M.predicted among blacks [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (CKD-EPI)' for http://loinc.org#88293-6. Valid display is one of 3 choices: 'Glomerular filtration rate [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (CKD-EPI)/1.73 sq M among black population' (en-US), 'Glomerular filtration rate [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (CKD-EPI)/1.73 sq M among black population' (en-US) or 'GFR/BSA pred.blk SerPlBld CKD-EPI-ArVRat' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Glomerular filtration rate/1.73 sq M.predicted among blacks [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (MDRD)' for http://loinc.org#48643-1. Valid display is one of 3 choices: 'Glomerular filtration rate [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (MDRD)/1.73 sq M among black population' (en-US), 'Glomerular filtration rate [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (MDRD)/1.73 sq M among black population' (en-US) or 'GFR SerPlBld Creatinine-bsd fmla /1.73sq' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Glomerular filtration rate/1.73 sq M.predicted among females [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (MDRD)' for http://loinc.org#50044-7. Valid display is one of 3 choices: 'Glomerular filtration rate [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (MDRD)/1.73 sq M among female population' (en-US), 'Glomerular filtration rate [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (MDRD)/1.73 sq M among female population' (en-US) or 'GFR SerPlBld Creatinine-bsd fmla FML' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Glomerular filtration rate/1.73 sq M.predicted among males [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (MDRD)' for http://loinc.org#70969-1. Valid display is one of 3 choices: 'Glomerular filtration rate [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (MDRD)/1.73 sq M among male population' (en-US), 'Glomerular filtration rate [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (MDRD)/1.73 sq M among male population' (en-US) or 'GFR SerPlBld Creatinine-bsd fmlaMale' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Glomerular filtration rate/1.73 sq M.predicted among non-blacks [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (CKD-EPI)' for http://loinc.org#88294-4. Valid display is one of 3 choices: 'Glomerular filtration rate [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (CKD-EPI)/1.73 sq M among non black population' (en-US), 'Glomerular filtration rate [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (CKD-EPI)/1.73 sq M among non black population' (en-US) or 'GFR/BSA pred.nonblk SerPl CKD-EPI-ArVRat' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Glomerular filtration rate/1.73 sq M.predicted among non-blacks [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (MDRD)' for http://loinc.org#48642-3. Valid display is one of 3 choices: 'Glomerular filtration rate [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (MDRD)/1.73 sq M among non black population' (en-US), 'Glomerular filtration rate [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (MDRD)/1.73 sq M among non black population' (en-US) or 'GFR/BSA pr.non blk SerPlBld MDRD-ArV' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Cystatin C and Glomerular filtration rate by Cystatin-based formula panel - Serum or Plasma' for http://loinc.org#87430-5. Valid display is one of 3 choices: 'Cystatin C and Glomerular filtration rate by Cystatin C-based formula panel - Serum or Plasma' (en-US), 'Cystatin C and Glomerular filtration rate by Cystatin C-based formula panel - Serum or Plasma' (en-US) or 'Cystatin C + GFR by Cystatin C Pnl SerPl' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Glomerular filtration rate/1.73 sq M.predicted [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine and Cystatin C-based formula (CKD-EPI)' for http://loinc.org#94677-2. Valid display is one of 3 choices: 'Glomerular filtration rate [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine and Cystatin C-based formula (CKD-EPI)/1.73 sq M' (en-US), 'Glomerular filtration rate [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine and Cystatin C-based formula (CKD-EPI)/1.73 sq M' (en-US) or 'GFR/BSA.pred SerPlBld Creat+Cyst CKD-EPI' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Glomerular filtration rate/1.73 sq M.predicted [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (CKD-EPI 2021)' for http://loinc.org#98979-8. Valid display is one of 3 choices: 'Glomerular filtration rate [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (CKD-EPI 2021)/1.73 sq M' (en-US), 'Glomerular filtration rate [Volume Rate/Area] in Serum, Plasma or Blood by Creatinine-based formula (CKD-EPI 2021)/1.73 sq M' (en-US) or 'eGFRcr SerPlBld CKD-EPI 2021' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Hematocrit [Volume Fraction] of Blood' for http://loinc.org#20570-8. Valid display is one of 3 choices: 'Hematocrit [Volume Fraction] of Blood by calculation' (en-US), 'Hematocrit [Volume Fraction] of Blood by calculation' (en-US) or 'Hct VFr Bld Calc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Hematocrit [Volume Fraction] of Capillary blood' for http://loinc.org#42908-4. Valid display is one of 3 choices: 'Hematocrit [Volume Fraction] of Capillary blood by calculation' (en-US), 'Hematocrit [Volume Fraction] of Capillary blood by calculation' (en-US) or 'Hct VFr BldC Calc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Hematocrit [Volume Fraction] of Venous blood' for http://loinc.org#41654-5. Valid display is one of 3 choices: 'Hematocrit [Volume Fraction] of Venous blood by calculation' (en-US), 'Hematocrit [Volume Fraction] of Venous blood by calculation' (en-US) or 'Hct VFr BldV Calc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Hematocrit [Pure volume fraction] of Venous blood' for http://loinc.org#71829-6. Valid display is one of 3 choices: 'Hematocrit [Pure volume fraction] of Venous blood by calculation' (en-US), 'Hematocrit [Pure volume fraction] of Venous blood by calculation' (en-US) or 'Hct VFr.DF BldV Calc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Hematocrit [Pure volume fraction] of Capillary blood' for http://loinc.org#71831-2. Valid display is one of 3 choices: 'Hematocrit [Pure volume fraction] of Capillary blood by calculation' (en-US), 'Hematocrit [Pure volume fraction] of Capillary blood by calculation' (en-US) or 'Hct VFr.DF BldC Calc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Platelet mean volume [Entitic volume] in Blood' for http://loinc.org#28542-9. Valid display is one of 3 choices: 'Platelet [Entitic mean volume] in Blood' (en-US), 'Platelet [Entitic mean volume] in Blood' (en-US) or 'PMV Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Platelet mean volume [Entitic volume] in Blood by Automated count' for http://loinc.org#32623-1. Valid display is one of 3 choices: 'Platelet [Entitic mean volume] in Blood by Automated count' (en-US), 'Platelet [Entitic mean volume] in Blood by Automated count' (en-US) or 'PMV Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Lymphocytes/100 leukocytes in Blood' for http://loinc.org#26478-8. Valid display is one of 3 choices: 'Lymphocytes/Leukocytes in Blood' (en-US), 'Lymphocytes/Leukocytes in Blood' (en-US) or 'Lymphocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Lymphocytes/100 leukocytes in Blood by Automated count' for http://loinc.org#736-9. Valid display is one of 3 choices: 'Lymphocytes/Leukocytes in Blood by Automated count' (en-US), 'Lymphocytes/Leukocytes in Blood by Automated count' (en-US) or 'Lymphocytes NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Lymphocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#737-7. Valid display is one of 3 choices: 'Lymphocytes/Leukocytes in Blood by Manual count' (en-US), 'Lymphocytes/Leukocytes in Blood by Manual count' (en-US) or 'Lymphocytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Monocytes/100 leukocytes in Blood by Automated count' for http://loinc.org#5905-5. Valid display is one of 3 choices: 'Monocytes/Leukocytes in Blood by Automated count' (en-US), 'Monocytes/Leukocytes in Blood by Automated count' (en-US) or 'Monocytes NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Monocytes/100 leukocytes in Blood' for http://loinc.org#26485-3. Valid display is one of 3 choices: 'Monocytes/Leukocytes in Blood' (en-US), 'Monocytes/Leukocytes in Blood' (en-US) or 'Monocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Monocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#744-3. Valid display is one of 3 choices: 'Monocytes/Leukocytes in Blood by Manual count' (en-US), 'Monocytes/Leukocytes in Blood by Manual count' (en-US) or 'Monocytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Neutrophils/100 leukocytes in Blood by Automated count' for http://loinc.org#770-8. Valid display is one of 3 choices: 'Neutrophils/Leukocytes in Blood by Automated count' (en-US), 'Neutrophils/Leukocytes in Blood by Automated count' (en-US) or 'Neutrophils NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Neutrophils/100 leukocytes in Blood' for http://loinc.org#26511-6. Valid display is one of 3 choices: 'Neutrophils/Leukocytes in Blood' (en-US), 'Neutrophils/Leukocytes in Blood' (en-US) or 'Neutrophils NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Neutrophils/100 leukocytes in Blood by Manual count' for http://loinc.org#23761-0. Valid display is one of 3 choices: 'Neutrophils/Leukocytes in Blood by Manual count' (en-US), 'Neutrophils/Leukocytes in Blood by Manual count' (en-US) or 'Neutrophils NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Band form neutrophils/100 leukocytes in Blood' for http://loinc.org#26508-2. Valid display is one of 3 choices: 'Band form neutrophils/Leukocytes in Blood' (en-US), 'Band form neutrophils/Leukocytes in Blood' (en-US) or 'Neuts Band NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Band form neutrophils/100 leukocytes in Blood by Manual count' for http://loinc.org#764-1. Valid display is one of 3 choices: 'Band form neutrophils/Leukocytes in Blood by Manual count' (en-US), 'Band form neutrophils/Leukocytes in Blood by Manual count' (en-US) or 'Neuts Band NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Band form neutrophils/100 leukocytes in Blood by Automated count' for http://loinc.org#35332-6. Valid display is one of 3 choices: 'Band form neutrophils/Leukocytes in Blood by Automated count' (en-US), 'Band form neutrophils/Leukocytes in Blood by Automated count' (en-US) or 'Neuts Band NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Segmented neutrophils/100 leukocytes in Blood by Automated count' for http://loinc.org#32200-8. Valid display is one of 3 choices: 'Segmented neutrophils/Leukocytes in Blood by Automated count' (en-US), 'Segmented neutrophils/Leukocytes in Blood by Automated count' (en-US) or 'Neuts Seg NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Segmented neutrophils/100 leukocytes in Blood' for http://loinc.org#26505-8. Valid display is one of 3 choices: 'Segmented neutrophils/Leukocytes in Blood' (en-US), 'Segmented neutrophils/Leukocytes in Blood' (en-US) or 'Neuts Seg NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Segmented neutrophils/100 leukocytes in Blood by Manual count' for http://loinc.org#769-0. Valid display is one of 3 choices: 'Segmented neutrophils/Leukocytes in Blood by Manual count' (en-US), 'Segmented neutrophils/Leukocytes in Blood by Manual count' (en-US) or 'Neuts Seg NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Blasts/100 leukocytes in Blood' for http://loinc.org#709-6. Valid display is one of 3 choices: 'Blasts/Leukocytes in Blood by Manual count' (en-US), 'Blasts/Leukocytes in Blood by Manual count' (en-US) or 'Blasts NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Blasts/100 leukocytes in Blood' for http://loinc.org#26446-5. Valid display is one of 3 choices: 'Blasts/Leukocytes in Blood' (en-US), 'Blasts/Leukocytes in Blood' (en-US) or 'Blasts NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Basophils/100 leukocytes in Blood by Manual count' for http://loinc.org#707-0. Valid display is one of 3 choices: 'Basophils/Leukocytes in Blood by Manual count' (en-US), 'Basophils/Leukocytes in Blood by Manual count' (en-US) or 'Basophils NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Basophils/100 leukocytes in Blood by Automated count' for http://loinc.org#706-2. Valid display is one of 3 choices: 'Basophils/Leukocytes in Blood by Automated count' (en-US), 'Basophils/Leukocytes in Blood by Automated count' (en-US) or 'Basophils NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Basophils/100 leukocytes in Blood' for http://loinc.org#30180-4. Valid display is one of 3 choices: 'Basophils/Leukocytes in Blood' (en-US), 'Basophils/Leukocytes in Blood' (en-US) or 'Basophils NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Eosinophils/100 leukocytes in Blood' for http://loinc.org#26450-7. Valid display is one of 3 choices: 'Eosinophils/Leukocytes in Blood' (en-US), 'Eosinophils/Leukocytes in Blood' (en-US) or 'Eosinophil NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Eosinophils/100 leukocytes in Blood by Automated count' for http://loinc.org#713-8. Valid display is one of 3 choices: 'Eosinophils/Leukocytes in Blood by Automated count' (en-US), 'Eosinophils/Leukocytes in Blood by Automated count' (en-US) or 'Eosinophil NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Eosinophils/100 leukocytes in Blood by Manual count' for http://loinc.org#714-6. Valid display is one of 3 choices: 'Eosinophils/Leukocytes in Blood by Manual count' (en-US), 'Eosinophils/Leukocytes in Blood by Manual count' (en-US) or 'Eosinophil NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Plasma cells/100 leukocytes in Blood' for http://loinc.org#13047-6. Valid display is one of 3 choices: 'Plasma cells/Leukocytes in Blood' (en-US), 'Plasma cells/Leukocytes in Blood' (en-US) or 'Plasma Cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Plasma cells/100 leukocytes in Blood by Manual count' for http://loinc.org#79426-3. Valid display is one of 3 choices: 'Plasma cells/Leukocytes in Blood by Manual count' (en-US), 'Plasma cells/Leukocytes in Blood by Manual count' (en-US) or 'Plasma Cells NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Promonocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#13599-6. Valid display is one of 3 choices: 'Promonocytes/Leukocytes in Blood by Manual count' (en-US), 'Promonocytes/Leukocytes in Blood by Manual count' (en-US) or 'Promonycytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Promonocytes/100 leukocytes in Blood' for http://loinc.org#30466-7. Valid display is one of 3 choices: 'Promonocytes/Leukocytes in Blood' (en-US), 'Promonocytes/Leukocytes in Blood' (en-US) or 'Promonycytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Promyelocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#783-1. Valid display is one of 3 choices: 'Promyelocytes/Leukocytes in Blood by Manual count' (en-US), 'Promyelocytes/Leukocytes in Blood by Manual count' (en-US) or 'Promyelocytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Promyelocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#26524-9. Valid display is one of 3 choices: 'Promyelocytes/Leukocytes in Blood' (en-US), 'Promyelocytes/Leukocytes in Blood' (en-US) or 'Promyelocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Myeloblasts/100 leukocytes in Blood' for http://loinc.org#30445-1. Valid display is one of 3 choices: 'Myeloblasts/Leukocytes in Blood' (en-US), 'Myeloblasts/Leukocytes in Blood' (en-US) or 'Myeloblasts NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Myeloblasts/100 leukocytes in Blood by Manual count' for http://loinc.org#747-6. Valid display is one of 3 choices: 'Myeloblasts/Leukocytes in Blood by Manual count' (en-US), 'Myeloblasts/Leukocytes in Blood by Manual count' (en-US) or 'Myeloblasts NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Myelocytes/100 leukocytes in Blood' for http://loinc.org#26498-6. Valid display is one of 3 choices: 'Myelocytes/Leukocytes in Blood' (en-US), 'Myelocytes/Leukocytes in Blood' (en-US) or 'Myelocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Myelocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#749-2. Valid display is one of 3 choices: 'Myelocytes/Leukocytes in Blood by Manual count' (en-US), 'Myelocytes/Leukocytes in Blood by Manual count' (en-US) or 'Myelocytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Metamyelocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#740-1. Valid display is one of 3 choices: 'Metamyelocytes/Leukocytes in Blood by Manual count' (en-US), 'Metamyelocytes/Leukocytes in Blood by Manual count' (en-US) or 'Metamyelocytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Metamyelocytes/100 leukocytes in Blood' for http://loinc.org#28541-1. Valid display is one of 3 choices: 'Metamyelocytes/Leukocytes in Blood' (en-US), 'Metamyelocytes/Leukocytes in Blood' (en-US) or 'Metamyelocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Prolymphocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#6746-2. Valid display is one of 3 choices: 'Prolymphocytes/Leukocytes in Blood by Manual count' (en-US), 'Prolymphocytes/Leukocytes in Blood by Manual count' (en-US) or 'Prolymphocytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Prolymphocytes/100 leukocytes in Blood' for http://loinc.org#30465-9. Valid display is one of 3 choices: 'Prolymphocytes/Leukocytes in Blood' (en-US), 'Prolymphocytes/Leukocytes in Blood' (en-US) or 'Prolymphocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Reticulocytes/100 erythrocytes in Blood by Manual' for http://loinc.org#31112-6. Valid display is one of 3 choices: 'Reticulocytes/Erythrocytes in Blood by Manual' (en-US), 'Reticulocytes/Erythrocytes in Blood by Manual' (en-US) or 'Retics/RBC NFr Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Reticulocytes/100 erythrocytes in Blood by Automated count' for http://loinc.org#17849-1. Valid display is one of 3 choices: 'Reticulocytes/Erythrocytes in Blood by Automated count' (en-US), 'Reticulocytes/Erythrocytes in Blood by Automated count' (en-US) or 'Retics/RBC NFr Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Reticulocytes/100 erythrocytes in Blood' for http://loinc.org#4679-7. Valid display is one of 3 choices: 'Reticulocytes/Erythrocytes in Blood' (en-US), 'Reticulocytes/Erythrocytes in Blood' (en-US) or 'Retics/RBC NFr' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-2022.jsonWrong Display Name 'Blasts/100 cells in Bone marrow' for http://loinc.org#11150-0. Valid display is one of 3 choices: 'Blasts/cells in Bone marrow' (en-US), 'Blasts/cells in Bone marrow' (en-US) or 'Blasts NFr Mar' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Band form neutrophils/100 leukocytes in Blood' for http://loinc.org#26508-2. Valid display is one of 3 choices: 'Band form neutrophils/Leukocytes in Blood' (en-US), 'Band form neutrophils/Leukocytes in Blood' (en-US) or 'Neuts Band NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Band form neutrophils/100 leukocytes in Blood by Automated count' for http://loinc.org#35332-6. Valid display is one of 3 choices: 'Band form neutrophils/Leukocytes in Blood by Automated count' (en-US), 'Band form neutrophils/Leukocytes in Blood by Automated count' (en-US) or 'Neuts Band NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Band form neutrophils/100 leukocytes in Blood by Manual count' for http://loinc.org#764-1. Valid display is one of 3 choices: 'Band form neutrophils/Leukocytes in Blood by Manual count' (en-US), 'Band form neutrophils/Leukocytes in Blood by Manual count' (en-US) or 'Neuts Band NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Basophils/100 leukocytes in Blood' for http://loinc.org#30180-4. Valid display is one of 3 choices: 'Basophils/Leukocytes in Blood' (en-US), 'Basophils/Leukocytes in Blood' (en-US) or 'Basophils NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Basophils/100 leukocytes in Blood by Automated count' for http://loinc.org#706-2. Valid display is one of 3 choices: 'Basophils/Leukocytes in Blood by Automated count' (en-US), 'Basophils/Leukocytes in Blood by Automated count' (en-US) or 'Basophils NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Basophils/100 leukocytes in Blood by Manual count' for http://loinc.org#707-0. Valid display is one of 3 choices: 'Basophils/Leukocytes in Blood by Manual count' (en-US), 'Basophils/Leukocytes in Blood by Manual count' (en-US) or 'Basophils NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Blasts/100 leukocytes in Blood' for http://loinc.org#26446-5. Valid display is one of 3 choices: 'Blasts/Leukocytes in Blood' (en-US), 'Blasts/Leukocytes in Blood' (en-US) or 'Blasts NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Blasts/100 leukocytes in Blood by Manual count' for http://loinc.org#709-6. Valid display is one of 3 choices: 'Blasts/Leukocytes in Blood by Manual count' (en-US), 'Blasts/Leukocytes in Blood by Manual count' (en-US) or 'Blasts NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Eosinophils/100 leukocytes in Blood' for http://loinc.org#26450-7. Valid display is one of 3 choices: 'Eosinophils/Leukocytes in Blood' (en-US), 'Eosinophils/Leukocytes in Blood' (en-US) or 'Eosinophil NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Eosinophils/100 leukocytes in Blood by Automated count' for http://loinc.org#713-8. Valid display is one of 3 choices: 'Eosinophils/Leukocytes in Blood by Automated count' (en-US), 'Eosinophils/Leukocytes in Blood by Automated count' (en-US) or 'Eosinophil NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Eosinophils/100 leukocytes in Blood by Manual count' for http://loinc.org#714-6. Valid display is one of 3 choices: 'Eosinophils/Leukocytes in Blood by Manual count' (en-US), 'Eosinophils/Leukocytes in Blood by Manual count' (en-US) or 'Eosinophil NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Hematocrit [Volume Fraction] of Blood' for http://loinc.org#20570-8. Valid display is one of 3 choices: 'Hematocrit [Volume Fraction] of Blood by calculation' (en-US), 'Hematocrit [Volume Fraction] of Blood by calculation' (en-US) or 'Hct VFr Bld Calc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Hematocrit [Pure volume fraction] of Capillary blood' for http://loinc.org#71831-2. Valid display is one of 3 choices: 'Hematocrit [Pure volume fraction] of Capillary blood by calculation' (en-US), 'Hematocrit [Pure volume fraction] of Capillary blood by calculation' (en-US) or 'Hct VFr.DF BldC Calc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Hematocrit [Pure volume fraction] of Venous blood' for http://loinc.org#71829-6. Valid display is one of 3 choices: 'Hematocrit [Pure volume fraction] of Venous blood by calculation' (en-US), 'Hematocrit [Pure volume fraction] of Venous blood by calculation' (en-US) or 'Hct VFr.DF BldV Calc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Hematocrit [Volume Fraction] of Capillary blood' for http://loinc.org#42908-4. Valid display is one of 3 choices: 'Hematocrit [Volume Fraction] of Capillary blood by calculation' (en-US), 'Hematocrit [Volume Fraction] of Capillary blood by calculation' (en-US) or 'Hct VFr BldC Calc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Hematocrit [Volume Fraction] of Venous blood' for http://loinc.org#41654-5. Valid display is one of 3 choices: 'Hematocrit [Volume Fraction] of Venous blood by calculation' (en-US), 'Hematocrit [Volume Fraction] of Venous blood by calculation' (en-US) or 'Hct VFr BldV Calc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Lymphocytes/100 leukocytes in Blood' for http://loinc.org#26478-8. Valid display is one of 3 choices: 'Lymphocytes/Leukocytes in Blood' (en-US), 'Lymphocytes/Leukocytes in Blood' (en-US) or 'Lymphocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Lymphocytes/100 leukocytes in Blood by Automated count' for http://loinc.org#736-9. Valid display is one of 3 choices: 'Lymphocytes/Leukocytes in Blood by Automated count' (en-US), 'Lymphocytes/Leukocytes in Blood by Automated count' (en-US) or 'Lymphocytes NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Lymphocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#737-7. Valid display is one of 3 choices: 'Lymphocytes/Leukocytes in Blood by Manual count' (en-US), 'Lymphocytes/Leukocytes in Blood by Manual count' (en-US) or 'Lymphocytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Metamyelocytes/100 leukocytes in Blood' for http://loinc.org#28541-1. Valid display is one of 3 choices: 'Metamyelocytes/Leukocytes in Blood' (en-US), 'Metamyelocytes/Leukocytes in Blood' (en-US) or 'Metamyelocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Metamyelocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#740-1. Valid display is one of 3 choices: 'Metamyelocytes/Leukocytes in Blood by Manual count' (en-US), 'Metamyelocytes/Leukocytes in Blood by Manual count' (en-US) or 'Metamyelocytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Monocytes/100 leukocytes in Blood' for http://loinc.org#26485-3. Valid display is one of 3 choices: 'Monocytes/Leukocytes in Blood' (en-US), 'Monocytes/Leukocytes in Blood' (en-US) or 'Monocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Monocytes/100 leukocytes in Blood by Automated count' for http://loinc.org#5905-5. Valid display is one of 3 choices: 'Monocytes/Leukocytes in Blood by Automated count' (en-US), 'Monocytes/Leukocytes in Blood by Automated count' (en-US) or 'Monocytes NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Monocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#744-3. Valid display is one of 3 choices: 'Monocytes/Leukocytes in Blood by Manual count' (en-US), 'Monocytes/Leukocytes in Blood by Manual count' (en-US) or 'Monocytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Myeloblasts/100 leukocytes in Blood' for http://loinc.org#30445-1. Valid display is one of 3 choices: 'Myeloblasts/Leukocytes in Blood' (en-US), 'Myeloblasts/Leukocytes in Blood' (en-US) or 'Myeloblasts NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Myeloblasts/100 leukocytes in Blood by Manual count' for http://loinc.org#747-6. Valid display is one of 3 choices: 'Myeloblasts/Leukocytes in Blood by Manual count' (en-US), 'Myeloblasts/Leukocytes in Blood by Manual count' (en-US) or 'Myeloblasts NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Myelocytes/100 leukocytes in Blood' for http://loinc.org#26498-6. Valid display is one of 3 choices: 'Myelocytes/Leukocytes in Blood' (en-US), 'Myelocytes/Leukocytes in Blood' (en-US) or 'Myelocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Myelocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#749-2. Valid display is one of 3 choices: 'Myelocytes/Leukocytes in Blood by Manual count' (en-US), 'Myelocytes/Leukocytes in Blood by Manual count' (en-US) or 'Myelocytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Neutrophils/100 leukocytes in Blood' for http://loinc.org#26511-6. Valid display is one of 3 choices: 'Neutrophils/Leukocytes in Blood' (en-US), 'Neutrophils/Leukocytes in Blood' (en-US) or 'Neutrophils NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Neutrophils/100 leukocytes in Blood by Automated count' for http://loinc.org#770-8. Valid display is one of 3 choices: 'Neutrophils/Leukocytes in Blood by Automated count' (en-US), 'Neutrophils/Leukocytes in Blood by Automated count' (en-US) or 'Neutrophils NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Neutrophils/100 leukocytes in Blood by Manual count' for http://loinc.org#23761-0. Valid display is one of 3 choices: 'Neutrophils/Leukocytes in Blood by Manual count' (en-US), 'Neutrophils/Leukocytes in Blood by Manual count' (en-US) or 'Neutrophils NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Plasma cells/100 leukocytes in Blood' for http://loinc.org#13047-6. Valid display is one of 3 choices: 'Plasma cells/Leukocytes in Blood' (en-US), 'Plasma cells/Leukocytes in Blood' (en-US) or 'Plasma Cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Plasma cells/100 leukocytes in Blood by Manual count' for http://loinc.org#79426-3. Valid display is one of 3 choices: 'Plasma cells/Leukocytes in Blood by Manual count' (en-US), 'Plasma cells/Leukocytes in Blood by Manual count' (en-US) or 'Plasma Cells NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Platelet mean volume [Entitic volume] in Blood' for http://loinc.org#28542-9. Valid display is one of 3 choices: 'Platelet [Entitic mean volume] in Blood' (en-US), 'Platelet [Entitic mean volume] in Blood' (en-US) or 'PMV Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Platelet mean volume [Entitic volume] in Blood by Automated count' for http://loinc.org#32623-1. Valid display is one of 3 choices: 'Platelet [Entitic mean volume] in Blood by Automated count' (en-US), 'Platelet [Entitic mean volume] in Blood by Automated count' (en-US) or 'PMV Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Prolymphocytes/100 leukocytes in Blood' for http://loinc.org#30465-9. Valid display is one of 3 choices: 'Prolymphocytes/Leukocytes in Blood' (en-US), 'Prolymphocytes/Leukocytes in Blood' (en-US) or 'Prolymphocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Prolymphocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#6746-2. Valid display is one of 3 choices: 'Prolymphocytes/Leukocytes in Blood by Manual count' (en-US), 'Prolymphocytes/Leukocytes in Blood by Manual count' (en-US) or 'Prolymphocytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Promonocytes/100 leukocytes in Blood' for http://loinc.org#30466-7. Valid display is one of 3 choices: 'Promonocytes/Leukocytes in Blood' (en-US), 'Promonocytes/Leukocytes in Blood' (en-US) or 'Promonycytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Promonocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#13599-6. Valid display is one of 3 choices: 'Promonocytes/Leukocytes in Blood by Manual count' (en-US), 'Promonocytes/Leukocytes in Blood by Manual count' (en-US) or 'Promonycytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Promyelocytes/100 leukocytes in Blood' for http://loinc.org#26524-9. Valid display is one of 3 choices: 'Promyelocytes/Leukocytes in Blood' (en-US), 'Promyelocytes/Leukocytes in Blood' (en-US) or 'Promyelocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Promyelocytes/100 leukocytes in Blood by Manual count' for http://loinc.org#783-1. Valid display is one of 3 choices: 'Promyelocytes/Leukocytes in Blood by Manual count' (en-US), 'Promyelocytes/Leukocytes in Blood by Manual count' (en-US) or 'Promyelocytes NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Albumin [Moles/volume] in Urine by Detection limit <= 3.0 mg/L' for http://loinc.org#77158-4. Valid display is one of 3 choices: 'Microalbumin [Moles/volume] in Urine by Detection limit <= 3.0 mg/L' (en-US), 'Microalbumin [Moles/volume] in Urine by Detection limit <= 3.0 mg/L' (en-US) or 'Microalbumin Ur DL<=3.0 mg/L-sCnc' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Blasts/100 cells in Bone marrow' for http://loinc.org#11150-0. Valid display is one of 3 choices: 'Blasts/cells in Bone marrow' (en-US), 'Blasts/cells in Bone marrow' (en-US) or 'Blasts NFr Mar' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Segmented neutrophils/100 leukocytes in Blood' for http://loinc.org#26505-8. Valid display is one of 3 choices: 'Segmented neutrophils/Leukocytes in Blood' (en-US), 'Segmented neutrophils/Leukocytes in Blood' (en-US) or 'Neuts Seg NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Segmented neutrophils/100 leukocytes in Blood by Automated count' for http://loinc.org#32200-8. Valid display is one of 3 choices: 'Segmented neutrophils/Leukocytes in Blood by Automated count' (en-US), 'Segmented neutrophils/Leukocytes in Blood by Automated count' (en-US) or 'Neuts Seg NFr Bld Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Segmented neutrophils/100 leukocytes in Blood by Manual count' for http://loinc.org#769-0. Valid display is one of 3 choices: 'Segmented neutrophils/Leukocytes in Blood by Manual count' (en-US), 'Segmented neutrophils/Leukocytes in Blood by Manual count' (en-US) or 'Neuts Seg NFr Bld Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Reticulocytes/100 erythrocytes in Blood' for http://loinc.org#4679-7. Valid display is one of 3 choices: 'Reticulocytes/Erythrocytes in Blood' (en-US), 'Reticulocytes/Erythrocytes in Blood' (en-US) or 'Retics/RBC NFr' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Reticulocytes/100 erythrocytes in Blood by Automated count' for http://loinc.org#17849-1. Valid display is one of 3 choices: 'Reticulocytes/Erythrocytes in Blood by Automated count' (en-US), 'Reticulocytes/Erythrocytes in Blood by Automated count' (en-US) or 'Retics/RBC NFr Auto' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-cibmtr-priority-variables-epic-2021.jsonWrong Display Name 'Reticulocytes/100 erythrocytes in Blood by Manual' for http://loinc.org#31112-6. Valid display is one of 3 choices: 'Reticulocytes/Erythrocytes in Blood by Manual' (en-US), 'Reticulocytes/Erythrocytes in Blood by Manual' (en-US) or 'Retics/RBC NFr Manual' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Basophils/100 leukocytes in Blood' for http://loinc.org#30180-4. Valid display is one of 3 choices: 'Basophils/Leukocytes in Blood' (en-US), 'Basophils/Leukocytes in Blood' (en-US) or 'Basophils NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Immature basophils/100 leukocytes in Blood' for http://loinc.org#34911-8. Valid display is one of 3 choices: 'Immature basophils/Leukocytes in Blood' (en-US), 'Immature basophils/Leukocytes in Blood' (en-US) or 'Imm Basophils NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Blasts/100 leukocytes in Blood' for http://loinc.org#26446-5. Valid display is one of 3 choices: 'Blasts/Leukocytes in Blood' (en-US), 'Blasts/Leukocytes in Blood' (en-US) or 'Blasts NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Eosinophils/100 leukocytes in Blood' for http://loinc.org#26450-7. Valid display is one of 3 choices: 'Eosinophils/Leukocytes in Blood' (en-US), 'Eosinophils/Leukocytes in Blood' (en-US) or 'Eosinophil NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Immature eosinophils/100 leukocytes in Blood' for http://loinc.org#34913-4. Valid display is one of 3 choices: 'Immature eosinophils/Leukocytes in Blood' (en-US), 'Immature eosinophils/Leukocytes in Blood' (en-US) or 'Imm Eosinophil NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Granulocytes/100 leukocytes in Blood' for http://loinc.org#30395-8. Valid display is one of 3 choices: 'Granulocytes/Leukocytes in Blood' (en-US), 'Granulocytes/Leukocytes in Blood' (en-US) or 'Granulocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Hairy cells/100 leukocytes in Blood' for http://loinc.org#35058-7. Valid display is one of 3 choices: 'Hairy cells/Leukocytes in Blood' (en-US), 'Hairy cells/Leukocytes in Blood' (en-US) or 'Hairy Cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Large unstained cells/100 leukocytes in Blood' for http://loinc.org#26463-0. Valid display is one of 3 choices: 'Large unstained cells/Leukocytes in Blood' (en-US), 'Large unstained cells/Leukocytes in Blood' (en-US) or 'LUC NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Leukocytes other/100 leukocytes in Blood' for http://loinc.org#26471-3. Valid display is one of 3 choices: 'Leukocytes other/Leukocytes in Blood' (en-US), 'Leukocytes other/Leukocytes in Blood' (en-US) or 'WBC Other NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Lymphoblasts/100 leukocytes in Blood' for http://loinc.org#34922-5. Valid display is one of 3 choices: 'Lymphoblasts/Leukocytes in Blood' (en-US), 'Lymphoblasts/Leukocytes in Blood' (en-US) or 'Lymphoblasts NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Lymphocytes/100 leukocytes in Blood' for http://loinc.org#26478-8. Valid display is one of 3 choices: 'Lymphocytes/Leukocytes in Blood' (en-US), 'Lymphocytes/Leukocytes in Blood' (en-US) or 'Lymphocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Abnormal lymphocytes/100 leukocytes in Blood' for http://loinc.org#30413-9. Valid display is one of 3 choices: 'Abnormal lymphocytes/Leukocytes in Blood' (en-US), 'Abnormal lymphocytes/Leukocytes in Blood' (en-US) or 'Lymph Abn NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Variant lymphocytes/100 leukocytes in Blood' for http://loinc.org#13046-8. Valid display is one of 3 choices: 'Variant lymphocytes/Leukocytes in Blood' (en-US), 'Variant lymphocytes/Leukocytes in Blood' (en-US) or 'Variant Lymphs NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Large granular lymphocytes/100 leukocytes in Blood' for http://loinc.org#30420-4. Valid display is one of 3 choices: 'Large granular lymphocytes/Leukocytes in Blood' (en-US), 'Large granular lymphocytes/Leukocytes in Blood' (en-US) or 'Lg Gran Lymphs NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Lymphocytes Plasmacytoid/100 leukocytes in Blood' for http://loinc.org#34921-7. Valid display is one of 3 choices: 'Lymphocytes Plasmacytoid/Leukocytes in Blood' (en-US), 'Lymphocytes Plasmacytoid/Leukocytes in Blood' (en-US) or 'Plasmacoid Lymphs NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Lymphoma cells/100 leukocytes in Blood' for http://loinc.org#30423-8. Valid display is one of 3 choices: 'Lymphoma cells/Leukocytes in Blood' (en-US), 'Lymphoma cells/Leukocytes in Blood' (en-US) or 'Lymphoma Cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Malignant cells/100 leukocytes in Blood' for http://loinc.org#34915-9. Valid display is one of 3 choices: 'Malignant cells/Leukocytes in Blood' (en-US), 'Malignant cells/Leukocytes in Blood' (en-US) or 'Malignant cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Metamyelocytes/100 leukocytes in Blood' for http://loinc.org#28541-1. Valid display is one of 3 choices: 'Metamyelocytes/Leukocytes in Blood' (en-US), 'Metamyelocytes/Leukocytes in Blood' (en-US) or 'Metamyelocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Monoblasts/100 leukocytes in Blood' for http://loinc.org#34923-3. Valid display is one of 3 choices: 'Monoblasts/Leukocytes in Blood' (en-US), 'Monoblasts/Leukocytes in Blood' (en-US) or 'Monoblasts NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Monocytes/100 leukocytes in Blood' for http://loinc.org#26485-3. Valid display is one of 3 choices: 'Monocytes/Leukocytes in Blood' (en-US), 'Monocytes/Leukocytes in Blood' (en-US) or 'Monocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Monocytes Abnormal/100 leukocytes in Blood' for http://loinc.org#30441-0. Valid display is one of 3 choices: 'Monocytes Abnormal/Leukocytes in Blood' (en-US), 'Monocytes Abnormal/Leukocytes in Blood' (en-US) or 'Abn Monocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Immature monocytes/100 leukocytes in Blood' for http://loinc.org#34925-8. Valid display is one of 3 choices: 'Immature monocytes/Leukocytes in Blood' (en-US), 'Immature monocytes/Leukocytes in Blood' (en-US) or 'Imm Moncytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Myeloblasts/100 leukocytes in Blood' for http://loinc.org#30445-1. Valid display is one of 3 choices: 'Myeloblasts/Leukocytes in Blood' (en-US), 'Myeloblasts/Leukocytes in Blood' (en-US) or 'Myeloblasts NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Myelocytes/100 leukocytes in Blood' for http://loinc.org#26498-6. Valid display is one of 3 choices: 'Myelocytes/Leukocytes in Blood' (en-US), 'Myelocytes/Leukocytes in Blood' (en-US) or 'Myelocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Neutrophils/100 leukocytes in Blood' for http://loinc.org#26511-6. Valid display is one of 3 choices: 'Neutrophils/Leukocytes in Blood' (en-US), 'Neutrophils/Leukocytes in Blood' (en-US) or 'Neutrophils NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Band form neutrophils/100 leukocytes in Blood' for http://loinc.org#26508-2. Valid display is one of 3 choices: 'Band form neutrophils/Leukocytes in Blood' (en-US), 'Band form neutrophils/Leukocytes in Blood' (en-US) or 'Neuts Band NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Neutrophils.hypersegmented/100 leukocytes in Blood' for http://loinc.org#30450-1. Valid display is one of 3 choices: 'Neutrophils.hypersegmented/Leukocytes in Blood' (en-US), 'Neutrophils.hypersegmented/Leukocytes in Blood' (en-US) or 'Neuts Hyperseg NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Segmented neutrophils/100 leukocytes in Blood' for http://loinc.org#26505-8. Valid display is one of 3 choices: 'Segmented neutrophils/Leukocytes in Blood' (en-US), 'Segmented neutrophils/Leukocytes in Blood' (en-US) or 'Neuts Seg NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Plasma cell precursor/100 leukocytes in Blood' for http://loinc.org#34917-5. Valid display is one of 3 choices: 'Plasma cell precursor/Leukocytes in Blood' (en-US), 'Plasma cell precursor/Leukocytes in Blood' (en-US) or 'Plasma cell prec NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Plasma cells/100 leukocytes in Blood' for http://loinc.org#13047-6. Valid display is one of 3 choices: 'Plasma cells/Leukocytes in Blood' (en-US), 'Plasma cells/Leukocytes in Blood' (en-US) or 'Plasma Cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Polymorphonuclear cells/100 leukocytes in Blood' for http://loinc.org#34999-3. Valid display is one of 3 choices: 'Deprecated Polymorphonuclear cells/100 leukocytes in Blood' (en-US), 'Deprecated Polymorphonuclear cells/100 leukocytes in Blood' (en-US) or 'Deprecated Polys/leuk NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Polymorphonuclear cells [#/volume] in Blood' for http://loinc.org#35003-3. Valid display is one of 3 choices: 'Deprecated Polymorphonuclear cells [#/volume] in Blood' (en-US), 'Deprecated Polymorphonuclear cells [#/volume] in Blood' (en-US) or 'Deprecated Polys # Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Prolymphocytes/100 leukocytes in Blood' for http://loinc.org#30465-9. Valid display is one of 3 choices: 'Prolymphocytes/Leukocytes in Blood' (en-US), 'Prolymphocytes/Leukocytes in Blood' (en-US) or 'Prolymphocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Promonocytes/100 leukocytes in Blood' for http://loinc.org#30466-7. Valid display is one of 3 choices: 'Promonocytes/Leukocytes in Blood' (en-US), 'Promonocytes/Leukocytes in Blood' (en-US) or 'Promonycytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Promyelocytes/100 leukocytes in Blood' for http://loinc.org#26524-9. Valid display is one of 3 choices: 'Promyelocytes/Leukocytes in Blood' (en-US), 'Promyelocytes/Leukocytes in Blood' (en-US) or 'Promyelocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Sezary cells/100 leukocytes in Blood' for http://loinc.org#34919-1. Valid display is one of 3 choices: 'Sezary cells/Leukocytes in Blood' (en-US), 'Sezary cells/Leukocytes in Blood' (en-US) or 'Sezary Cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-differential-unspecified-blood-vs.jsonWrong Display Name 'Smudge cells/100 leukocytes in Blood' for http://loinc.org#34992-8. Valid display is one of 3 choices: 'Smudge cells/Leukocytes in Blood' (en-US), 'Smudge cells/Leukocytes in Blood' (en-US) or 'Smudge Cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-erythrocyte-morphology-blood-vs.jsonWrong Display Name 'Erythrocyte morphology finding [Identifier] in Blood' for http://loinc.org#6742-1. Valid display is one of 3 choices: 'Erythrocyte [Morphology] in Blood' (en-US), 'Erythrocyte [Morphology] in Blood' (en-US) or 'RBC morph Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-leukocyte-morphology-blood-vs.jsonWrong Display Name 'Leukocyte morphology finding [Identifier] in Blood' for http://loinc.org#11156-7. Valid display is one of 3 choices: 'Leukocytes [Morphology] in Blood' (en-US), 'Leukocytes [Morphology] in Blood' (en-US) or 'WBC Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Basophils/100 leukocytes in Blood' for http://loinc.org#30180-4. Valid display is one of 3 choices: 'Basophils/Leukocytes in Blood' (en-US), 'Basophils/Leukocytes in Blood' (en-US) or 'Basophils NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Immature basophils/100 leukocytes in Blood' for http://loinc.org#34911-8. Valid display is one of 3 choices: 'Immature basophils/Leukocytes in Blood' (en-US), 'Immature basophils/Leukocytes in Blood' (en-US) or 'Imm Basophils NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Blasts/100 leukocytes in Blood' for http://loinc.org#26446-5. Valid display is one of 3 choices: 'Blasts/Leukocytes in Blood' (en-US), 'Blasts/Leukocytes in Blood' (en-US) or 'Blasts NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Eosinophils/100 leukocytes in Blood' for http://loinc.org#26450-7. Valid display is one of 3 choices: 'Eosinophils/Leukocytes in Blood' (en-US), 'Eosinophils/Leukocytes in Blood' (en-US) or 'Eosinophil NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Immature eosinophils/100 leukocytes in Blood' for http://loinc.org#34913-4. Valid display is one of 3 choices: 'Immature eosinophils/Leukocytes in Blood' (en-US), 'Immature eosinophils/Leukocytes in Blood' (en-US) or 'Imm Eosinophil NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Granulocytes/100 leukocytes in Blood' for http://loinc.org#30395-8. Valid display is one of 3 choices: 'Granulocytes/Leukocytes in Blood' (en-US), 'Granulocytes/Leukocytes in Blood' (en-US) or 'Granulocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Hairy cells/100 leukocytes in Blood' for http://loinc.org#35058-7. Valid display is one of 3 choices: 'Hairy cells/Leukocytes in Blood' (en-US), 'Hairy cells/Leukocytes in Blood' (en-US) or 'Hairy Cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Large unstained cells/100 leukocytes in Blood' for http://loinc.org#26463-0. Valid display is one of 3 choices: 'Large unstained cells/Leukocytes in Blood' (en-US), 'Large unstained cells/Leukocytes in Blood' (en-US) or 'LUC NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Leukocytes other/100 leukocytes in Blood' for http://loinc.org#26471-3. Valid display is one of 3 choices: 'Leukocytes other/Leukocytes in Blood' (en-US), 'Leukocytes other/Leukocytes in Blood' (en-US) or 'WBC Other NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Lymphoblasts/100 leukocytes in Blood' for http://loinc.org#34922-5. Valid display is one of 3 choices: 'Lymphoblasts/Leukocytes in Blood' (en-US), 'Lymphoblasts/Leukocytes in Blood' (en-US) or 'Lymphoblasts NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Lymphocytes/100 leukocytes in Blood' for http://loinc.org#26478-8. Valid display is one of 3 choices: 'Lymphocytes/Leukocytes in Blood' (en-US), 'Lymphocytes/Leukocytes in Blood' (en-US) or 'Lymphocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Abnormal lymphocytes/100 leukocytes in Blood' for http://loinc.org#30413-9. Valid display is one of 3 choices: 'Abnormal lymphocytes/Leukocytes in Blood' (en-US), 'Abnormal lymphocytes/Leukocytes in Blood' (en-US) or 'Lymph Abn NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Variant lymphocytes/100 leukocytes in Blood' for http://loinc.org#13046-8. Valid display is one of 3 choices: 'Variant lymphocytes/Leukocytes in Blood' (en-US), 'Variant lymphocytes/Leukocytes in Blood' (en-US) or 'Variant Lymphs NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Large granular lymphocytes/100 leukocytes in Blood' for http://loinc.org#30420-4. Valid display is one of 3 choices: 'Large granular lymphocytes/Leukocytes in Blood' (en-US), 'Large granular lymphocytes/Leukocytes in Blood' (en-US) or 'Lg Gran Lymphs NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Lymphocytes Plasmacytoid/100 leukocytes in Blood' for http://loinc.org#34921-7. Valid display is one of 3 choices: 'Lymphocytes Plasmacytoid/Leukocytes in Blood' (en-US), 'Lymphocytes Plasmacytoid/Leukocytes in Blood' (en-US) or 'Plasmacoid Lymphs NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Lymphoma cells/100 leukocytes in Blood' for http://loinc.org#30423-8. Valid display is one of 3 choices: 'Lymphoma cells/Leukocytes in Blood' (en-US), 'Lymphoma cells/Leukocytes in Blood' (en-US) or 'Lymphoma Cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Malignant cells/100 leukocytes in Blood' for http://loinc.org#34915-9. Valid display is one of 3 choices: 'Malignant cells/Leukocytes in Blood' (en-US), 'Malignant cells/Leukocytes in Blood' (en-US) or 'Malignant cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Metamyelocytes/100 leukocytes in Blood' for http://loinc.org#28541-1. Valid display is one of 3 choices: 'Metamyelocytes/Leukocytes in Blood' (en-US), 'Metamyelocytes/Leukocytes in Blood' (en-US) or 'Metamyelocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Monoblasts/100 leukocytes in Blood' for http://loinc.org#34923-3. Valid display is one of 3 choices: 'Monoblasts/Leukocytes in Blood' (en-US), 'Monoblasts/Leukocytes in Blood' (en-US) or 'Monoblasts NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Monocytes/100 leukocytes in Blood' for http://loinc.org#26485-3. Valid display is one of 3 choices: 'Monocytes/Leukocytes in Blood' (en-US), 'Monocytes/Leukocytes in Blood' (en-US) or 'Monocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Monocytes Abnormal/100 leukocytes in Blood' for http://loinc.org#30441-0. Valid display is one of 3 choices: 'Monocytes Abnormal/Leukocytes in Blood' (en-US), 'Monocytes Abnormal/Leukocytes in Blood' (en-US) or 'Abn Monocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Immature monocytes/100 leukocytes in Blood' for http://loinc.org#34925-8. Valid display is one of 3 choices: 'Immature monocytes/Leukocytes in Blood' (en-US), 'Immature monocytes/Leukocytes in Blood' (en-US) or 'Imm Moncytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Myeloblasts/100 leukocytes in Blood' for http://loinc.org#30445-1. Valid display is one of 3 choices: 'Myeloblasts/Leukocytes in Blood' (en-US), 'Myeloblasts/Leukocytes in Blood' (en-US) or 'Myeloblasts NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Myelocytes/100 leukocytes in Blood' for http://loinc.org#26498-6. Valid display is one of 3 choices: 'Myelocytes/Leukocytes in Blood' (en-US), 'Myelocytes/Leukocytes in Blood' (en-US) or 'Myelocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Neutrophils/100 leukocytes in Blood' for http://loinc.org#26511-6. Valid display is one of 3 choices: 'Neutrophils/Leukocytes in Blood' (en-US), 'Neutrophils/Leukocytes in Blood' (en-US) or 'Neutrophils NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Band form neutrophils/100 leukocytes in Blood' for http://loinc.org#26508-2. Valid display is one of 3 choices: 'Band form neutrophils/Leukocytes in Blood' (en-US), 'Band form neutrophils/Leukocytes in Blood' (en-US) or 'Neuts Band NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Neutrophils.hypersegmented/100 leukocytes in Blood' for http://loinc.org#30450-1. Valid display is one of 3 choices: 'Neutrophils.hypersegmented/Leukocytes in Blood' (en-US), 'Neutrophils.hypersegmented/Leukocytes in Blood' (en-US) or 'Neuts Hyperseg NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Segmented neutrophils/100 leukocytes in Blood' for http://loinc.org#26505-8. Valid display is one of 3 choices: 'Segmented neutrophils/Leukocytes in Blood' (en-US), 'Segmented neutrophils/Leukocytes in Blood' (en-US) or 'Neuts Seg NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Plasma cell precursor/100 leukocytes in Blood' for http://loinc.org#34917-5. Valid display is one of 3 choices: 'Plasma cell precursor/Leukocytes in Blood' (en-US), 'Plasma cell precursor/Leukocytes in Blood' (en-US) or 'Plasma cell prec NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Plasma cells/100 leukocytes in Blood' for http://loinc.org#13047-6. Valid display is one of 3 choices: 'Plasma cells/Leukocytes in Blood' (en-US), 'Plasma cells/Leukocytes in Blood' (en-US) or 'Plasma Cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Polymorphonuclear cells/100 leukocytes in Blood' for http://loinc.org#34999-3. Valid display is one of 3 choices: 'Deprecated Polymorphonuclear cells/100 leukocytes in Blood' (en-US), 'Deprecated Polymorphonuclear cells/100 leukocytes in Blood' (en-US) or 'Deprecated Polys/leuk NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Polymorphonuclear cells [#/volume] in Blood' for http://loinc.org#35003-3. Valid display is one of 3 choices: 'Deprecated Polymorphonuclear cells [#/volume] in Blood' (en-US), 'Deprecated Polymorphonuclear cells [#/volume] in Blood' (en-US) or 'Deprecated Polys # Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Prolymphocytes/100 leukocytes in Blood' for http://loinc.org#30465-9. Valid display is one of 3 choices: 'Prolymphocytes/Leukocytes in Blood' (en-US), 'Prolymphocytes/Leukocytes in Blood' (en-US) or 'Prolymphocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Promonocytes/100 leukocytes in Blood' for http://loinc.org#30466-7. Valid display is one of 3 choices: 'Promonocytes/Leukocytes in Blood' (en-US), 'Promonocytes/Leukocytes in Blood' (en-US) or 'Promonycytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Promyelocytes/100 leukocytes in Blood' for http://loinc.org#26524-9. Valid display is one of 3 choices: 'Promyelocytes/Leukocytes in Blood' (en-US), 'Promyelocytes/Leukocytes in Blood' (en-US) or 'Promyelocytes NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Sezary cells/100 leukocytes in Blood' for http://loinc.org#34919-1. Valid display is one of 3 choices: 'Sezary cells/Leukocytes in Blood' (en-US), 'Sezary cells/Leukocytes in Blood' (en-US) or 'Sezary Cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-manual-differential-blood-vs.jsonWrong Display Name 'Smudge cells/100 leukocytes in Blood' for http://loinc.org#34992-8. Valid display is one of 3 choices: 'Smudge cells/Leukocytes in Blood' (en-US), 'Smudge cells/Leukocytes in Blood' (en-US) or 'Smudge Cells NFr Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-patient.jsonWrong Display Name 'Body weight Patient Mass Pt Qn Measured' for http://loinc.org#3141-9. Valid display is one of 3 choices: 'Body weight Measured' (en-US), 'Body weight Measured' (en-US) or 'Weight Measured' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-patient.jsonWrong Display Name 'Clothing worn during measure Patient Type Pt Nom' for http://loinc.org#8352-7. Valid display is one of 3 choices: 'Clothing worn during measure' (en-US), 'Clothing worn during measure' (en-US) or 'Clothing worn during measure' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-patient.jsonWrong Display Name 'Body position with respect to gravity Patient Type Pt Nom' for http://loinc.org#8361-8. Valid display is one of 3 choices: 'Body position with respect to gravity' (en-US), 'Body position with respect to gravity' (en-US) or 'Bdy position with respect to gravity' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-platelet-morphology-blood-vs.jsonWrong Display Name 'Platelet morphology finding [Identifier] in Blood' for http://loinc.org#11125-2. Valid display is one of 3 choices: 'Platelets [Morphology] in Blood' (en-US), 'Platelets [Morphology] in Blood' (en-US) or 'Platelet Bld' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-vital-signs.jsonWrong Display Name 'Body weight Patient Mass Pt Qn' for http://loinc.org#29463-7. Valid display is one of 3 choices: 'Body weight' (en-US), 'Body weight' (en-US) or 'Weight' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
fsh-generated\resources\ValueSet-vital-signs.jsonWrong Display Name 'Body height Patient Len Pt Qn' for http://loinc.org#8302-2. Valid display is one of 3 choices: 'Body height' (en-US), 'Body height' (en-US) or 'Body height' (en-US) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code